On-line monitoring and analysis of the dielectric loss in cross-bonded HV cable system

被引:12
|
作者
Yang, Yang [1 ]
Hepburn, Donald M. [1 ]
Zhou, Chengke [1 ]
Zhou, Wenjun [2 ]
Jiang, Wei [3 ]
Tian, Zhi [3 ]
机构
[1] Glasgow Caledonian Univ, Sch Engn & Built Environm, Glasgow G4 0BA, Lanark, Scotland
[2] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Hubei, Peoples R China
[3] Wuhan Power Supply Co, China State Grid, Wuhan 430022, Hubei, Peoples R China
关键词
On-line monitoring; Leakage current; Dielectric loss; XLPE; Cross bonding; Three-phase; XLPE CABLE;
D O I
10.1016/j.epsr.2017.03.036
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dielectric loss has long been recognized as one of the most important indicators of cable insulation health. Although huge efforts have been made in the past to measure the dielectric loss of cable circuits, there has been no report of any successful on-line techniques for the purpose. This paper proposes a new on-line insulation dielectric loss monitoring method, based on separation of currents collected from the co-axial cables connecting the cable sheathes and the cable link boxes. The principle and theoretical foundation of the method are demonstrated. MATLAB simulations, based on the real cable parameters in a 110 kV cable tunnel in China, indicate the error of the proposed method is less than 1 x 10(-3)%. The criteria for determining the relative dielectric loss in cable segments, based on the leakage current separation results, are demonstrated at the end. Initial results and analysis of implementation of the proposed method in the real world 110 kV cable tunnel are presented. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:89 / 101
页数:13
相关论文
共 50 条
  • [1] On-line Monitoring and Trending of Dielectric Loss in a Cross-bonded HV Cable System
    Yang, Yang
    Hepburn, Donald M.
    Zhou, Chengke
    Jiang, Wei
    Yang, Bin
    Zhou, Wenjun
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 301 - 304
  • [2] On-line PD Detection and Localization in Cross-bonded HV Cable Systems
    Sheng, Bojie
    Zhou, Wenjun
    Yu, Jianhui
    Meng, Shaoxin
    Zhou, Chengke
    Hepburn, Donald M.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (05) : 2217 - 2224
  • [3] On-line Monitoring of Relative Dielectric Losses in Cross-bonded Cables Using Sheath Currents
    Yang, Yang
    Hepburn, D. M.
    Zhou, Chengke
    Zhou, Wenjun
    Bao, Yuchuan
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (05) : 2677 - 2685
  • [4] A Novel Fault Location Method for a Cross-Bonded HV Cable System Based on Sheath Current Monitoring
    Li, Mingzhen
    Zhou, Chengke
    Zhou, Wenjun
    Wang, Chunlin
    Yao, Leiming
    Su, Mengting
    Huang, Xiaojun
    SENSORS, 2018, 18 (10)
  • [5] A Novel Fault Localization Method Based on Monitoring of Sheath Current in a Cross-bonded HV Cable System
    Li, Mingzhen
    Zhou, Wenjun
    Wang, Chunlin
    Yao, Leiming
    Su, Mengting
    Huang, Xiaojun
    Zhou, Chengke
    2017 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2017, : 123 - 126
  • [6] TRANSIENT ANALYSIS OF A CROSS-BONDED CABLE SYSTEM UNDERNEATH A BRIDGE
    ITOH, Y
    NAGAOKA, N
    AMETANI, A
    IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (02) : 527 - 532
  • [7] Investigation of Partial Discharge Propagation in Cross-bonded HV Cable Systems
    Sheng, Bojie
    Zhou, Chengke
    Hepburn, Donald M.
    Dong, Xiang
    Zhou, Wenjun
    Yu, Janhui
    2014 ELECTRICAL INSULATION CONFERENCE (EIC), 2014, : 19 - 23
  • [8] Analysis of non-linearities in cross-bonded cable systems
    AbdelGawad, NMK
    ENERGY CONVERSION AND MANAGEMENT, 1997, 38 (04) : 377 - 400
  • [9] Electrical parameters of cross-bonded cable lines
    Kanicki, Andrzej
    Wisniewski, Jozef
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (9A): : 32 - 37