Cryopreservation of MHC Multimers: Recommendations for Quality Assurance in Detection of Antigen Specific T Cells

被引:17
作者
Hadrup, Sine Reker [1 ]
Maurer, Dominik [2 ]
Laske, Karoline [3 ,4 ]
Frosig, Thomas Morch [1 ]
Andersen, Sofie Ramskov [1 ]
Britten, Cedrik M. [5 ]
van der Burg, Sjoerd H. [6 ]
Walter, Steffen [2 ]
Gouttefangeas, Cecile [3 ,4 ]
机构
[1] Herlev Univ Hosp, CCIT, Dept Hematol, DK-6509 Herlev, Denmark
[2] Immat Biotechnol GmbH, Tubingen, Germany
[3] Univ Tubingen, Dept Immunol, Inst Cell Biol, Tubingen, Germany
[4] DKTK, Tubingen, Germany
[5] Johannes Gutenberg Univ Mainz gGmbH, Univ Med Ctr, Mainz, Germany
[6] Leiden Univ, Med Ctr, Dept Clin Oncol, Leiden, Netherlands
关键词
MHC multimer; cryopreservation; cryoprotectant; recommendations for MHC multimer storage; quality assurance; glycerol in T cell staining; PARALLEL DETECTION; PEPTIDE; FREQUENCY; VIRUS; PANEL; LYMPHOCYTES; RESPONSES; BINDING; DESIGN; ASSAYS;
D O I
10.1002/cyto.a.22575
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fluorescence-labeled peptide-MHC class I multimers serve as ideal tools for the detection of antigen-specific T cells by flow cytometry, enabling functional and phenotypical characterization of specific T cells at the single cell level. While this technique offers a number of unique advantages, MHC multimer reagents can be difficult to handle in terms of stability and quality assurance. The stability of a given fluorescence-labeled MHC multimer complex depends on both the stability of the peptide-MHC complex itself and the stability of the fluorochrome. Consequently, stability is difficult to predict and long-term storage is generally not recommended. We investigated here the possibility of cryopreserving MHC multimers, both in-house produced and commercially available, using a wide range of peptide-MHC class I multimers comprising virus and cancer-associated epitopes of different affinities presented by various HLA-class I molecules. Cryopreservation of MHC multimers was feasible for at least 6 months, when they were dissolved in buffer containing 5-16% glycerol (v/v) and 0.5% serum albumin (w/v). The addition of cryoprotectants was tolerated across three different T-cell staining protocols for all fluorescence labels tested (PE, APC, PE-Cy7 and Quantum dots). We propose cryopreservation as an easily implementable method for stable storage of MHC multimers and recommend the use of cryopreservation in long-term immunomonitoring projects, thereby eliminating the variability introduced by different batches and inconsistent stability. (c) 2014 International Society for Advancement of Cytometry
引用
收藏
页码:37 / 48
页数:12
相关论文
共 34 条
[11]   Interrogating the repertoire: broadening the scope of peptide-MHC multimer analysis [J].
Davis, Mark M. ;
Altman, John D. ;
Newell, Evan W. .
NATURE REVIEWS IMMUNOLOGY, 2011, 11 (08) :551-558
[12]   Adoptive cell therapy with autologous tumor infiltrating lymphocytes and low-dose Interleukin-2 in metastatic melanoma patients [J].
Ellebaek, Eva ;
Iversen, Trine Zeeberg ;
Junker, Niels ;
Donia, Marco ;
Engell-Noerregaard, Lotte ;
Met, Ozcan ;
Holmich, Lisbet Rosenkrantz ;
Andersen, Rikke Sick ;
Hadrup, Sine Reker ;
Andersen, Mads Hald ;
Straten, Per Thor ;
Svane, Inge Marie .
JOURNAL OF TRANSLATIONAL MEDICINE, 2012, 10
[13]   UNIQUE FEATURES OF ALBUMIN - A BRIEF REVIEW [J].
EMERSON, TE .
CRITICAL CARE MEDICINE, 1989, 17 (07) :690-694
[14]   STATUS OF CRYOPRESERVATION OF EMBRYOS FROM DOMESTIC-ANIMALS [J].
FAHNING, ML ;
GARCIA, MA .
CRYOBIOLOGY, 1992, 29 (01) :1-18
[15]  
Fishman Andrew I, 2012, J Clin Med Res, V4, P95, DOI 10.4021/jocmr833w
[16]  
Fuller BJ, 2004, CRYOLETTERS, V25, P375
[17]   Selective expansion of cross-reactive CD8+ memory T cells by viral variants [J].
Haanen, JBAG ;
Wolkers, MC ;
Kruisbeek, AM ;
Schumacher, TNM .
JOURNAL OF EXPERIMENTAL MEDICINE, 1999, 190 (09) :1319-1328
[18]   In situ detection of virus- and tumor-specific T-cell immunity [J].
Haanen, JBAG ;
Van Oijen, MGCT ;
Tirion, F ;
Oomen, LCJM ;
Kruisbeek, AM ;
Vyth-Dreese, FA ;
Schumacher, TNM .
NATURE MEDICINE, 2000, 6 (09) :1056-1060
[19]  
Hadrup SR, 2009, METHODS MOL BIOL, V524, P383, DOI 10.1007/978-1-59745-450-6_28
[20]   Parallel detection of antigen-specific T-cell responses by multidimensional encoding of MHC multimers [J].
Hadrup, Sine Reker ;
Bakker, Arnold H. ;
Shu, Chengyi J. ;
Andersen, Rikke S. ;
van Veluw, Jerre ;
Hombrink, Pleun ;
Castermans, Emilie ;
Straten, Per thor ;
Blank, Christian ;
Haanen, John B. ;
Heemskerk, Mirjam H. ;
Schumacher, Ton N. .
NATURE METHODS, 2009, 6 (07) :520-U79