A class of novel point similarity measures based on MAP-MRF framework for 2D-3D registation of X-ray fluoroscopy to CT images

被引:0
作者
Zheng, Guoyan [1 ]
Zhang, Xuan [1 ]
Nolte, Lutz-Peter [1 ]
机构
[1] Univ Bern, MEM Res Ctr, Stauffacherstr 78, CH-3014 Bern, Switzerland
来源
2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3 | 2006年
关键词
D O I
暂无
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
One of the main factors that affect the accuracy of 2D-3D registration of X-ray fluoroscopy to CT images is the similarity measure, which is a criterion function that is used in the registration procedure for measuring the quality of image match. Previously it was reported that pattern intensity was able to register accurately and robustly, even when soft tissues and interventional instruments were present in the fluoroscopy images. Unfortunately, pattern intensity was designed directly by using some heuristic rules. This paper presents a Markov Random Field (MRF) model for 2D-3D registration based on Bayesian framework. The optimal solution is defined as the maximum a posteriori (MAP) estimate of the MRF. By using this unified MAP-MRF framework, we derive a class of novel point similarity measures. We point out that pattern intensity is a member of this class. As examples, we present two novel point similarity measures of this class. Their behaviors are evaluated using a phantom and a human cadaveric spine specimen together with their respective ground truth and are compared to previously introduced similarity measures. We report their behavior comparison results and their registration accuracy.
引用
收藏
页码:438 / +
页数:2
相关论文
共 10 条
  • [1] Bansal R, 1998, LECT NOTES COMPUT SC, V1496, P1075, DOI 10.1007/BFb0056297
  • [2] BESAG J, 2003, J ROYAL STAT SOC B, V36, P1395
  • [3] Hamadeh A, 1998, Comput Aided Surg, V3, P11, DOI 10.3109/10929089809148123
  • [4] JONIC S, UNPUB INT J BIOMED
  • [5] Li SZ., 1995, Markov random field modeling in computer vision
  • [6] A comparison of similarity measures for use in 2-D-3-D medical image registration
    Penney, GP
    Weese, J
    Little, JA
    Desmedt, P
    Hill, DLG
    Hawkes, DJ
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (04) : 586 - 595
  • [7] ROZANOV IA, 1982, MARKOV RANDOM FIELDS
  • [8] 3-D/2-D registration of CT and MR to X-ray images
    Tomazevic, D
    Likar, B
    Slivnik, T
    Pernus, F
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (11) : 1407 - 1416
  • [9] Weese J, 1997, LECT NOTES COMPUT SC, V1205, P119, DOI 10.1007/BFb0029231
  • [10] Zheng GY, 2004, LECT NOTES COMPUT SC, V3150, P294