Cuff and aortic pressure differences during dobutamine infusion: A study of the effects of systolic blood pressure amplification

被引:11
作者
Smulyan, Harold [1 ]
Mukherjee, Ratnakar [2 ]
Sheehe, Paul R. [3 ]
Safar, Michel E. [4 ]
机构
[1] SUNY Syracuse, Dept Med, Div Cardiol, Upstate Med Univ, Syracuse, NY 13208 USA
[2] Baltimore Washington Med Ctr, Glen Burnie, MD USA
[3] SUNY Syracuse, Upstate Med Univ, Dept Neurosci & Physiol, Syracuse, NY 13208 USA
[4] Hop Hotel Dieu, Ctr Diagnost & Therapeut, F-75181 Paris, France
关键词
GENERALIZED TRANSFER-FUNCTION; STRESS ECHOCARDIOGRAPHY; ARTERIAL-HYPERTENSION; AUGMENTATION INDEX; CLINICAL UTILITY; PULSE PRESSURE; WAVE-FORM; VALIDATION; TONOMETRY; THERAPY;
D O I
10.1016/j.ahj.2009.12.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Central aortic systolic blood pressures (SBPs) differ from and are preferable to cuff pressures when calculating cardiac work, left ventricular wall stress, and rate-pressure product. Despite the widespread use of dobutamine, differences between aortic and brachial SBP (pulse amplification) and pulse transmission during dobutamine infusion have not been previously studied. This study assessed these differences and used applanated radial pulses with the Sphygmocor (AtCor Medical, Sydney, Australia) device to investigate the effects of dobutamine on arterial pulse transmission and pulse amplification. Methods Using a cuff oscillometer, brachial arterial pressures were measured simultaneously with directly recorded aortic pressures at rest and during increasing dobutamine infusion rates in 25 patients. In 15 of those patients, applanated radial pulses were fed into the Sphygmocor device and calibrated in 2 ways to predict aortic pressures. Results At peak dobutamine infusion, SBP amplification averaged 14.9 mm Hg, with a maximum difference of 43 mm Hg. When radial artery pulses were calibrated using cuff pressures, the Sphygmocor underestimated the aortic SBP at all dobutamine doses. However, when radial artery pulses were calibrated using the more accurate aortic mean and diastolic BPs, the Sphygmocor accurately predicted the aortic SBP at baseline, but not at the higher dobutamine doses. Conclusions Similar to exercise, dobutamine induced cuff SBPs and pulse pressures higher than those measured in the aorta-uncorrected by the cuff-calibrated Sphygmocor. This increasing pulse amplification was explained by the effects of dobutamine on the properties of the conduit arterial walls, on changes in pulse wave velocity, on increasing heart rate, and on reflected waves. (Am Heart J 2010; 159: 399-405.)
引用
收藏
页码:399 / 405
页数:7
相关论文
共 50 条
  • [41] Brachial Blood Pressure-Independent Relations Between Radial Late Systolic Shoulder-Derived Aortic Pressures and Target Organ Changes
    Norton, Gavin R.
    Majane, Olebogeng H. I.
    Maseko, Muzi J.
    Libhaber, Carlos
    Redelinghuys, Michelle
    Kruger, Deirdre
    Veller, Martin
    Sareli, Pinhas
    Woodiwiss, Angela J.
    HYPERTENSION, 2012, 59 (04) : 885 - U295
  • [42] Ethnic Differences in Blood Pressure and Hypertensive Complications During Pregnancy The Generation R Study
    Bouthoorn, Selma H.
    Gaillard, Romy
    Steegers, Eric A. P.
    Hofman, Albert
    Jaddoe, Vincent W. V.
    van Lenthe, Frank J.
    Raat, Hein
    HYPERTENSION, 2012, 60 (01) : 198 - 205
  • [43] Systolic blood pressure and mortality in prevalent haemodialysis patients in the HEMO study
    Chang, T. I.
    Friedman, G. D.
    Cheung, A. K.
    Greene, T.
    Desai, M.
    Chertow, G. M.
    JOURNAL OF HUMAN HYPERTENSION, 2011, 25 (02) : 98 - 105
  • [44] Central aortic blood pressure estimation in children and adolescents: results of the KidCoreBP study
    Mynard, Jonathan P.
    Goldsmith, Greta
    Springall, Gabriella
    Eastaugh, Lucas
    Lane, Geoffrey K.
    Zannino, Diana
    Smolich, Joseph J.
    Avolio, Alberto
    Cheung, Michael M. H.
    JOURNAL OF HYPERTENSION, 2020, 38 (05) : 821 - 828
  • [45] Sex differences in the contribution of blood pressure to acute changes in aortic augmentation index
    Prodel, Eliza
    Barbosa, Thales C.
    Galdino, Iuri
    Nobrega, Antonio C.
    Vianna, Lauro C.
    JOURNAL OF HUMAN HYPERTENSION, 2018, 32 (11) : 752 - 758
  • [46] The effects of NG-nitro-L-arginine methyl ester on systolic pressure, diastolic pressure and pulse pressure according to the initial level of blood pressure
    Ruiz, Antonio
    Lopez, Ruth M.
    Perez, Teresa
    Castillo, Carlos
    Castillo, Enrique F.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2008, 22 (01) : 45 - 52
  • [47] Central-to-peripheral systolic blood pressure different phenotypes and relation to accuracy of daily used cuff devices
    Bendary, Ahmed
    Magdy, Mina
    Aal, Sahar Abdoul
    Rashid, Hisham
    ARTERIAL HYPERTENSION, 2019, 23 (04): : 263 - 270
  • [48] A controlled study of the effects of isosorbide mononitrate on arterial blood pressure and pulse wave form in systolic hypertension
    Stokes, GS
    Ryan, M
    Brnabic, A
    Nyberg, G
    JOURNAL OF HYPERTENSION, 1999, 17 (12) : 1767 - 1773
  • [49] Effect of mechanical behaviour of the brachial artery on blood pressure measurement during both cuff inflation and cuff deflation
    Zheng, Dingchang
    Pan, Fan
    Murray, Alan
    BLOOD PRESSURE MONITORING, 2013, 18 (05) : 265 - 271
  • [50] Effects of short-term exercise-training on aortic systolic pressure augmentation in overweight and obese individuals
    Millen, Aletta M. E.
    Norton, Gavin R.
    Avidon, Ingrid
    Woodiwiss, Angela J.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2013, 113 (07) : 1793 - 1803