Cuff and aortic pressure differences during dobutamine infusion: A study of the effects of systolic blood pressure amplification

被引:11
作者
Smulyan, Harold [1 ]
Mukherjee, Ratnakar [2 ]
Sheehe, Paul R. [3 ]
Safar, Michel E. [4 ]
机构
[1] SUNY Syracuse, Dept Med, Div Cardiol, Upstate Med Univ, Syracuse, NY 13208 USA
[2] Baltimore Washington Med Ctr, Glen Burnie, MD USA
[3] SUNY Syracuse, Upstate Med Univ, Dept Neurosci & Physiol, Syracuse, NY 13208 USA
[4] Hop Hotel Dieu, Ctr Diagnost & Therapeut, F-75181 Paris, France
关键词
GENERALIZED TRANSFER-FUNCTION; STRESS ECHOCARDIOGRAPHY; ARTERIAL-HYPERTENSION; AUGMENTATION INDEX; CLINICAL UTILITY; PULSE PRESSURE; WAVE-FORM; VALIDATION; TONOMETRY; THERAPY;
D O I
10.1016/j.ahj.2009.12.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Central aortic systolic blood pressures (SBPs) differ from and are preferable to cuff pressures when calculating cardiac work, left ventricular wall stress, and rate-pressure product. Despite the widespread use of dobutamine, differences between aortic and brachial SBP (pulse amplification) and pulse transmission during dobutamine infusion have not been previously studied. This study assessed these differences and used applanated radial pulses with the Sphygmocor (AtCor Medical, Sydney, Australia) device to investigate the effects of dobutamine on arterial pulse transmission and pulse amplification. Methods Using a cuff oscillometer, brachial arterial pressures were measured simultaneously with directly recorded aortic pressures at rest and during increasing dobutamine infusion rates in 25 patients. In 15 of those patients, applanated radial pulses were fed into the Sphygmocor device and calibrated in 2 ways to predict aortic pressures. Results At peak dobutamine infusion, SBP amplification averaged 14.9 mm Hg, with a maximum difference of 43 mm Hg. When radial artery pulses were calibrated using cuff pressures, the Sphygmocor underestimated the aortic SBP at all dobutamine doses. However, when radial artery pulses were calibrated using the more accurate aortic mean and diastolic BPs, the Sphygmocor accurately predicted the aortic SBP at baseline, but not at the higher dobutamine doses. Conclusions Similar to exercise, dobutamine induced cuff SBPs and pulse pressures higher than those measured in the aorta-uncorrected by the cuff-calibrated Sphygmocor. This increasing pulse amplification was explained by the effects of dobutamine on the properties of the conduit arterial walls, on changes in pulse wave velocity, on increasing heart rate, and on reflected waves. (Am Heart J 2010; 159: 399-405.)
引用
收藏
页码:399 / 405
页数:7
相关论文
共 50 条
  • [31] Central aortic systolic blood pressure can predict prolonged QTc duration better than brachial artery systolic blood pressure in rural community residents
    Huang, Yuqing
    Tang, Songtao
    Chen, Ji-yan
    Huang, Cheng
    Li, Jie
    Cai, An-ping
    Feng, Yingqing
    CLINICAL AND EXPERIMENTAL HYPERTENSION, 2018, 40 (03) : 238 - 243
  • [32] Effects of Watermelon Supplementation on Aortic Blood Pressure and Wave Reflection in Individuals With Prehypertension: A Pilot Study
    Figueroa, Arturo
    Sanchez-Gonzalez, Marcos A.
    Perkins-Veazie, Penelope M.
    Arjmandi, Bahram H.
    AMERICAN JOURNAL OF HYPERTENSION, 2011, 24 (01) : 40 - 44
  • [33] COMPARATIVE EFFECTS OF ANTIHYPERTENSIVE DRUGS ON SYSTOLIC BLOOD-PRESSURE
    CHAIGNON, MM
    MOURAD, JJ
    GUEDON, J
    JOURNAL OF HYPERTENSION, 1993, 11 : S27 - S31
  • [34] A Model of Systolic Blood Pressure During the Course of Dialysis and Clinical Factors Associated With Various Blood Pressure Behaviors
    Dinesh, Kumar
    Kunaparaju, Srikanth
    Cape, Kathryn
    Flythe, Jennifer E.
    Feldman, Harold I.
    Brunelli, Steven M.
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2011, 58 (05) : 794 - 803
  • [35] Central Aortic Blood Pressure of Hypertensive Men During Short-Term Cold Exposure
    Hintsala, Heidi
    Kandelberg, Arno
    Herzig, Karl-Heinz
    Rintamaki, Hannu
    Mantysaari, Matti
    Rantala, Aino
    Antikainen, Riitta
    Keinanen-Kiukaanniemi, Sirkka
    Jaakkola, Jouni J. K.
    Ikaheimo, Tiina M.
    AMERICAN JOURNAL OF HYPERTENSION, 2014, 27 (05) : 656 - 664
  • [36] The impact of blood pressure cuff location on the accuracy of noninvasive blood pressure measurements in obese patients: an observational study
    Anast, Nicholas
    Olejniczak, Megan
    Ingrande, Jerry
    Brock-Utne, John
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2016, 63 (03): : 298 - 306
  • [37] Individualized Estimation of the Central Aortic Blood Pressure Waveform: A Comparative Study
    Hahn, Jin-Oh
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2014, 18 (01) : 215 - 221
  • [38] ANALYSIS OF THE IMPORTANCE OF SYSTOLIC BLOOD PRESSURE VERSUS DIASTOLIC BLOOD PRESSURE IN DIAGNOSING HYPERTENSION: MRA STUDY.
    Kandil, Heba
    Soliman, Ahmed
    Taher, Fatma
    Ghazal, Mohammed
    Hadi, Mohiuddin
    Elmaghraby, Add
    El-Baz, Ayman
    2020 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2020, : 443 - 447
  • [39] Differences in Effects of Age and Blood Pressure on Augmentation Index
    Tomiyama, Hirofumi
    Odaira, Mari
    Kimura, Kazutaka
    Matsumoto, Chisa
    Shiina, Kazuki
    Eguchi, Kazuo
    Miyashita, Hiroshi
    Shimada, Kazuyuki
    Yamashina, Akira
    AMERICAN JOURNAL OF HYPERTENSION, 2014, 27 (12) : 1479 - 1485
  • [40] Blood pressure changes during alemtuzumab infusion for multiple sclerosis patients
    Shosha, Eslam
    Casserly, Courtney
    Tomkinson, Christine
    Morrow, Sarah A.
    EUROPEAN JOURNAL OF NEUROLOGY, 2021, 28 (04) : 1396 - 1400