Minimally invasive plate osteosynthesis vs conventional fixation techniques for surgically treated humeral shaft fractures: a meta-analysis

被引:35
作者
Hu, Xuqi [1 ]
Xu, Siqi [2 ]
Lu, Huigen [1 ]
Chen, Bao [1 ]
Zhou, Xiao [1 ]
He, Xiaojun [1 ]
Dai, Jiaping [1 ]
Zhang, Zhongwei [1 ]
Gong, Suiliang [1 ]
机构
[1] Jiaxing Univ, Affiliated Hosp 2, Dept Orthopaed, 1518 Huancheng North Rd, Jiaxing, Peoples R China
[2] Jiaxing Univ, Affiliated Hosp 2, Dept Clin Lab, 1518 Huancheng North Rd, Jiaxing, Peoples R China
来源
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH | 2016年 / 11卷
关键词
Minimally invasive plate osteosynthesis; Open reduction with plate osteosynthesis; Intramedullary nail; Humeral shaft fracture; Meta-analysis; OPERATIVE TREATMENT; MIPPO TECHNIQUE; SHOULDER;
D O I
10.1186/s13018-016-0394-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: In this study, we performed a meta-analysis to identify whether minimally invasive plate osteosynthesis (MIPO) was superior to conventional fixation techniques (CFT) for treating humeral shaft fractures. Methods: A systematic literature search was conducted up to February 2016 in ScienceDirect, Springer, MEDLINE, and PubMed databases for relevant papers that compared the outcomes of MIPO with CFT, such as open reduction with plate osteosynthesis (ORPO) and intramedullary nail (IMN) for treating humeral shaft fractures. Meta-analysis was performed with Review Manager 5.0 software. Results: According to the search strategy, eight studies that covered 391 patients were enrolled, including four randomized controlled trials (RCTs), two prospective cohort trials, and two retrospective cohort trials. Our meta-analysis did not detect any significant difference between MIPO and CFT (IMN and ORPO) in terms of operative time, fracture union rate, and fracture union time. However, MIPO has a less rate of complications and iatrogenic radial nerve palsy than that of ORPO and higher adjacent joint function scores than those of IMN (p < 0.05). Conclusions: Based on the present evidence, this meta-analysis suggested that MIPO was a better choice for treating humeral shaft fractures than CFT. However, more high-quality randomized trials are still needed to further confirm this conclusion in the future.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Minimally invasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures
    Zhiquan, An
    Bingfang, Zeng
    Yeming, Wang
    Chi, Zhang
    Peiyan, Huang
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (09) : 628 - 633
  • [32] Minimally invasive plating osteosynthesis of proximal humeral shaft fractures with long PHILOS plates
    Brunner, A.
    Thormann, S.
    Babst, R.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2012, 24 (4-5): : 302 - 311
  • [33] Plating osteosynthesis of mid-distal humeral shaft fractures: minimally invasive versus conventional open reduction technique
    Zhiquan An
    Bingfang Zeng
    Xiaojian He
    Qi Chen
    Shundong Hu
    International Orthopaedics, 2010, 34 : 131 - 135
  • [34] Anterior medial minimally invasive plate osteosynthesis for humeral shaft fractures shows superior early shoulder and elbow function compared to locking compression plate: A retrospective study
    Yang, Zhenxing
    Ouyang, Botian
    Yang, Jing
    Liu, Dapeng
    Kang, Xin
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (08):
  • [35] Open plate fixation versus nailing for humeral shaft fractures: a meta-analysis and systematic review of randomised clinical trials and observational studies
    Beeres, Frank Joseph Paulus
    van Veelen, Nicole
    Houwert, Roderick Marijn
    Link, Bjorn Christian
    Heng, Marilyn
    Knobe, Matthias
    Groenwold, Rolf Hendrik Herman
    Babst, Reto
    van de Wall, Bryan Joost Marinus
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (04) : 2667 - 2682
  • [36] Anterior Minimally Invasive Plate Osteosynthesis for Humeral Shaft Fractures Is Safer Than Open Reduction Internal Fixation: A Matched Case-Controlled Comparison
    Randell, Matthew
    Glatt, Vaida
    Stabler, Annabelle
    Bussoletti, Timothy
    Hohmann, Erik
    Tetsworth, Kevin
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2021, 35 (08) : 424 - 429
  • [37] Case-Match Controlled Comparison of Minimally Invasive Plate Osteosynthesis and Intramedullary Nailing for the Stabilization of Humeral Shaft Fractures
    Davies, Gareth
    Yeo, Gerald
    Meta, Mahendrakumar
    Miller, David
    Hohmann, Erik
    Tetsworth, Kevin
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (11) : 612 - 617
  • [38] Early Full Range of Shoulder and Elbow Motion is Possible After Minimally Invasive Plate Osteosynthesis for Humeral Shaft Fractures
    Kobayashi, Makoto
    Watanabe, Yoshinobu
    Matsushita, Takashi
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (04) : 212 - 216
  • [39] Minimally invasive plating versus either open reduction and plate fixation or intramedullary nailing of humeral shaft fractures: a systematic review and meta-analysis of randomized controlled trials
    Hohmann, Erik
    Glatt, Vaida
    Tetsworth, Kevin
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (10) : 1634 - 1642
  • [40] Conservative Management with Functional Brace Versus Various Surgical Fixation Techniques for Humeral Shaft Fractures A Network Meta-Analysis
    Zavras, Athan G.
    Monahan, Kevin T.
    Winek, Nathan C.
    Pan, Tommy
    Altman, Gregory T.
    Altman, Daniel T.
    Westrick, Edward R.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2023, 105 (14) : 1112 - 1122