A comparison of dosimetric variance for external-beam partial breast irradiation using three-dimensional and four-dimensional computed tomography

被引:3
作者
Guo, Bing [1 ,2 ]
Li, Jian-Bin [2 ]
Wang, Wei [2 ]
Xu, Min [2 ]
Li, Yan-Kang [2 ,3 ]
Liu, Tong-Hai [2 ]
机构
[1] Univ Jinan, Shandong Acad Med Sci, Sch Med & Life Sci, Jinan, Shandong, Peoples R China
[2] Shandong Canc Hosp & Inst, Dept Radiat Oncol, 440 Jiyan Rd, Jinan 250117, Shandong, Peoples R China
[3] Shandong Univ, Sch Med, Jinan 250100, Shandong, Peoples R China
关键词
breast cancer; external-beam partial breast irradiation; three-dimensional computed tomography; four-dimensional computed tomography; dosimetric parameters; INTENSITY-MODULATED RADIOTHERAPY; TARGET VOLUME DELINEATION; SURGICAL CLIPS; FOLLOW-UP; CT SCANS; CANCER; SURGERY; MOTION; 4DCT; VARIABILITY;
D O I
10.2147/OTT.S100629
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose: To investigate the potential dosimetric benefits from four-dimensional computed tomography (4DCT) compared with three-dimensional computed tomography (3DCT) in radiotherapy treatment planning for external-beam partial breast irradiation (EB-PBI). Patients and methods: 3DCT and 4DCT scan sets were acquired for 20 patients who underwent EB-PBI. The volume of the tumor bed (TB) was determined based on seroma or surgical clips on 3DCT images (defined as TB3D) and the end inhalation (EI) and end exhalation (EE) phases of 4DCT images (defined as TBEI and TBEE, respectively). The clinical target volume (CTV) consisted of the TB plus a 1.0 cm margin. The planning target volume (PTV) was the CTV plus 0.5 cm (defined as PTV3D, PTVEI, and PTVEE). For each patient, a conventional 3D conformal plan (3D-CRT) was generated (defined as EB-PBI3D, EB-PBIEI, and EB-PBIEE). Results: The PTV3D, PTVEI, and PTVEE were similar (P=0.549), but the PTV coverage of EB-PBI3D was significantly less than that of EB-PBIEI or EB-PBIEE (P=0.001 and P=0.025, respectively). There were no significant differences in the homogeneity or conformity indexes between the three treatment plans (P=0.125 and P=0.536, respectively). The EB-PBI3D plan resulted in the largest organs at risk dose. Conclusion: There was a significant benefit for patients when using 3D-CRT based on 4DCT for EB-PBI with regard to reducing nontarget organ exposure. Respiratory motion did not affect the dosimetric distribution during free breathing, but might result in poor dose coverage when the PTV is determined using 3DCT.
引用
收藏
页码:1857 / 1863
页数:7
相关论文
共 27 条
[1]  
Abe O, 2005, LANCET, V366, P2087, DOI 10.1016/s0140-6736(05)66544-0
[2]   Comparison of Radiotherapy Treatment Plans for Left-sided Breast Cancer Patients based on Three- and Four-dimensional Computed Tomography Imaging [J].
Bedi, C. ;
Kron, T. ;
Willis, D. ;
Hubbard, P. ;
Milner, A. ;
Chua, B. .
CLINICAL ONCOLOGY, 2011, 23 (09) :601-607
[3]   Long-term results of breast conserving surgery vs. mastectomy for early stage invasive breast cancer:: 20-year follow-up of the Danish randomized DBCG-82TM protocol [J].
Blichert-Toft, Mogens ;
Nielsen, Maja ;
Duering, Maria ;
Moller, Susanne ;
Rank, Fritz ;
Overgaard, Marie ;
Mouridsen, Henning T. .
ACTA ONCOLOGICA, 2008, 47 (04) :672-681
[4]   Color intensity projections: A rapid approach for evaluating four-dimensional CT scans in treatment planning [J].
Cover, KS ;
Lagerwaard, FJ ;
Senan, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (03) :954-961
[5]   3D-conformal Accelerated Partial Breast Irradiation treatment planning: the value of surgical clips in the delineation of the lumpectomy cavity [J].
Dzhugashvili, Maia ;
Tournay, Elodie ;
Pichenot, Charlotte ;
Dunant, Ariane ;
Pessoa, Eduardo ;
Khallel, Adel ;
Gouy, Sebastien ;
Uzan, Catherine ;
Garbay, Jean-Remy ;
Rimareix, Francoise ;
Spielmann, Marc ;
Vielh, Philippe ;
Marsiglia, Hugo ;
Bourgier, Celine .
RADIATION ONCOLOGY, 2009, 4
[6]   Interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation [J].
Guo, Bing ;
Li, Jianbin ;
Wang, Wei ;
Xu, Min ;
Shao, Qian ;
Zhang, Yingjie ;
Liang, Chaoqian ;
Guo, Yanluan .
RADIATION ONCOLOGY, 2015, 10
[7]   Variability in target volume delineation on CT scans of the breast [J].
Hurkmans, CW ;
Borger, JH ;
Pieters, BR ;
Russell, NS ;
Jansen, EPM ;
Mijnheer, BJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (05) :1366-1372
[8]   Treatment planning evaluation of sliding window and multiple static segments technique in intensity modulated radiotherapy [J].
Iqbal, Khalid ;
Isa, Muhammad ;
Buzdar, Saeed Ahmad ;
Gifford, Kent Aallen ;
Afzal, Muhammad. .
REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2013, 18 (02) :101-106
[9]   Scanned proton radiotherapy for mobile targets-the effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristics [J].
Knopf, Antje-Christin ;
Hong, Theodore S. ;
Lomax, Antony .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (22) :7257-7271
[10]   Accelerated partial breast irradiation after conservative surgery for breast cancer [J].
Kuerer, HM ;
Julian, TB ;
Strom, EA ;
Lyerly, HK ;
Giuliano, AE ;
Mamounas, EP ;
Vicini, FA .
ANNALS OF SURGERY, 2004, 239 (03) :338-351