Calibration of gradient propagation delays for accurate two-dimensional radiofrequency pulses

被引:13
作者
Davies, NP [1 ]
Jezzard, P [1 ]
机构
[1] Univ Oxford, John Radcliffe Hosp, FMRIB Ctr, Dept Clin Neurol, Oxford OX3 9DU, England
关键词
calibration; gradient delays; 2D RF pulses; multidimensional selective excitation; propagation delays;
D O I
10.1002/mrm.20308
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Hardware-related delays between the requested and actual start times of the gradient waveforms on each physical axis are of particular importance for multidimensional selective excitation in which the synchronization of gradient and radiofrequency (RF) waveforms is critical. A method is proposed for the accurate calibration of gradient propagation delays to optimize the spatial accuracy of 2D RF pulses, although the results may also be used to reduce artifacts in other MR techniques. e sensitivity of 213 RF pulses to uncorrected time shifts between the gradient and RF waveforms was exploited to calibrate accurately the propagation delays on each physical gradient axis. This was achieved using a technique that relates the effect of gradient delays in the component waveforms of a constant-angular rate spiral k-space trajectory 2D RF pulse to the spatial location of the subsequent excitation profile. Comparison was also made with a procedure based on a previously described k-space plotting method, showing broad agreement, but with some discrepancies that illustrate the value of a self-referenced correction method for multidimensional RF pulses. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:231 / 236
页数:6
相关论文
共 9 条
[1]   Effects of gradient anisotropy in MRI [J].
Aldefeld, B ;
Börnert, P .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) :606-614
[2]   Selective arterial spin Labeling (SASL): Perfusion territory mapping of selected feeding arteries tagged using two-dimensional radiofrequency pulses [J].
Davies, NP ;
Jezzard, P .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (06) :1133-1142
[3]   Simple correction method for k-space trajectory deviations in MRI [J].
Duyn, JH ;
Yang, YH ;
Frank, JA ;
van der Veen, JW .
JOURNAL OF MAGNETIC RESONANCE, 1998, 132 (01) :150-153
[4]   A K-SPACE ANALYSIS OF SMALL-TIP-ANGLE EXCITATION [J].
PAULY, J ;
NISHIMURA, D ;
MACOVSKI, A .
JOURNAL OF MAGNETIC RESONANCE, 1989, 81 (01) :43-56
[5]   Centering the projection reconstruction trajectory: Reducing gradient delay errors [J].
Peters, DC ;
Derbyshire, JA ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) :1-6
[6]   Quantification and reduction of ghosting artifacts in interleaved echo-planar imaging [J].
Reeder, SB ;
Atalar, E ;
Bolster, BD ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :429-439
[7]  
Reeder SB, 1999, MAGNET RESON MED, V41, P87, DOI 10.1002/(SICI)1522-2594(199901)41:1<87::AID-MRM13>3.0.CO
[8]  
2-X
[9]   COMPENSATION OF MULTIDIMENSIONAL SELECTIVE EXCITATION PULSES USING MEASURED K-SPACE TRAJECTORIES [J].
TAKAHASHI, A ;
PETERS, T .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :446-456