Application of spectral derivative data in visible and near-infrared spectroscopy

被引:22
作者
Dehghani, Hamid [1 ,2 ]
Leblond, Frederic [2 ]
Pogue, Brian W. [2 ]
Chauchard, Fabien [3 ]
机构
[1] Univ Birmingham, Sch Comp Sci, Birmingham B15 2TT, W Midlands, England
[2] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
[3] Indatech, Prades Le Lez, France
基金
英国工程与自然科学研究理事会;
关键词
DIFFUSE OPTICAL TOMOGRAPHY; DEOXYHEMOGLOBIN CONCENTRATION; IMAGE-RECONSTRUCTION; PHOTON MIGRATION; BREAST-TISSUE; SCATTERING; BRAIN; LIGHT; QUANTIFICATION; SATURATION;
D O I
10.1088/0031-9155/55/12/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of the spectral derivative method in visible and near-infrared optical spectroscopy is presented, whereby instead of using discrete measurements around several wavelengths, the difference between nearest neighbouring spectral measurements is utilized. The proposed technique is shown to be insensitive to the unknown tissue and fibre contact coupling coefficients providing substantially increased accuracy as compared to more conventional techniques. The self-calibrating nature of the spectral derivative techniques increases its robustness for both clinical and industrial applications, as is demonstrated based on simulated results as well as experimental data.
引用
收藏
页码:3381 / 3399
页数:19
相关论文
共 38 条
[1]   Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: a computer simulation feasibility study [J].
Alexandrakis, G ;
Rannou, FR ;
Chatziioannou, AF .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (17) :4225-4241
[2]   Accurate myoglobin oxygen saturation by optical spectroscopy measured in blood-perfused rat muscle [J].
Arakaki, Lorilee S. L. ;
Burns, David H. ;
Kushmerick, Martin J. .
APPLIED SPECTROSCOPY, 2007, 61 (09) :978-985
[3]   MULTISPECTRAL ANALYSIS FOR QUANTITATIVE MEASUREMENTS OF MYOGLOBIN OXYGEN FRACTIONAL SATURATION IN THE PRESENCE OF HEMOGLOBIN INTERFERENCE [J].
ARAKAKI, LSL ;
BURNS, DH .
APPLIED SPECTROSCOPY, 1992, 46 (12) :1919-1928
[4]   Optical tomography in medical imaging [J].
Arridge, SR .
INVERSE PROBLEMS, 1999, 15 (02) :R41-R93
[5]  
Bank William, 1998, Biofactors, V7, P243
[6]   Simultaneous imaging and optode calibration with diffuse optical tomography [J].
Boas, DA ;
Gaudette, T ;
Arridge, SR .
OPTICS EXPRESS, 2001, 8 (05) :263-270
[7]   Near-infrared spectroscopy for monitoring of tissue oxygenation of exercising skeletal muscle in a chronic compartment syndrome model [J].
Breit, GA ;
Gross, JH ;
Watenpaugh, DE ;
Chance, B ;
Hargens, AR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (06) :838-843
[8]  
Brown SD, 2009, COMPREHENSIVE CHEMOMETRICS: CHEMICAL AND BIOCHEMICAL DATA ANALYSIS, VOLS 1-4, P1
[9]   Near-infrared (NIR) optical spectroscopy characterizes breast tissue hormonal and age status [J].
Chance, B .
ACADEMIC RADIOLOGY, 2001, 8 (03) :209-210
[10]   Simultaneous near-infrared spectroscopy monitoring of left and right occipital areas reveals contra-lateral hemodynamic changes upon hemi-field paradigm [J].
Colier, WNJM ;
Quaresima, V ;
Wenzel, R ;
van der Sluijs, MC ;
Oeseburg, B ;
Ferrari, M ;
Villringer, A .
VISION RESEARCH, 2001, 41 (01) :97-102