MRI detection of the thermal effects of focused ultrasound on the brain

被引:95
作者
Vykhodtseva, N
Sorrento, V
Jolesz, FA
Bronson, RT
Hynynen, K
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
[3] Tufts Univ, Sch Vet Med, Boston, MA 02111 USA
关键词
MRI; minimally invasive surgery; brain; focused ultrasound; ultrasound; thermal therapy; tissue ablation;
D O I
10.1016/S0301-5629(00)00216-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This study tested the hypothesis that MRI thermometry can be correlated with the different degrees of tissue damage observed after focused ultrasound (US) exposure of brain. The brains of 6 rabbits were sonicated to calibrate the MRI proton resonant shift with temperature, In addition, 13 rabbits were sonicated at acoustic powers ranging from 3.5 to 17.5 W. The experiments were performed in a 1.5-T MRI scanner with the temperature-sensitive phase imaging used during the sonications of 4-5 different locations in each rabbit. MR images mere obtained 2 h and 2 days after the sonications, depending on when the animals were sacrificed. Whole brain histologic evaluation was performed by sectioning the brain and performing a microscopic investigation. The MRI-derived temperature elevation was found to correlate well with the degree of tissue damage. In addition to the common histology findings, apoptotic cells were observed in the lesions, The T1-weighted contrast enhanced and T1-weighted scans both detected the brain damage. The applied acoustic power did not correlate well with the degree of damage. As a conclusion, the results showed that the measurement of temperature elevations by MRT during sonications can improve the accuracy and safety of clinical US brain surgery. (C) 2000 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:871 / 880
页数:10
相关论文
共 50 条
[31]   Therapies by focused ultrasound [J].
Grenier, N. ;
Trillaud, H. ;
Palussiere, J. ;
Mougenot, C. ;
Quesson, B. ;
de Senneville, B. Denis ;
Moonen, C. .
JOURNAL DE RADIOLOGIE, 2007, 88 (11) :1787-1800
[32]   Enhancement of Direct Brain Infusion with Focused Ultrasound and Microbubbles [J].
Wang, Shutao ;
Sun, Tao ;
Acosta, Camilo ;
Karakatsani, Maria Eleni ;
Olumolade, Oluyemi ;
Samiotaki, Gesthimani ;
Konofagou, Elisa .
2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, :2169-2172
[33]   Induction of apoptosis in vivo in the rabbit brain with focused ultrasound [J].
Vykhodtseva, Natalia I. ;
McDannold, Nathan ;
Hynynen, Kullervo .
THERAPEUTIC ULTRASOUND, 2006, 829 :213-+
[34]   Contrast-Enhanced Ultrasound Imaging for the Detection of Transient Dynamics of Blood-Brain Barrier Opening Induced by Focused Ultrasound [J].
Ting, Chien-Yu ;
Fan, Ching-Hsiang ;
Lin, Wun-Hao ;
Chai, Wen-Yen ;
Liu, Hao-Li ;
Yen, Tzu-Chen ;
Yeh, Chih-Kuang .
2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, :2088-2091
[35]   Biological effects of blood–brain barrier disruption using a focused ultrasound [J].
Han M. ;
Hur Y. ;
Hwang J. ;
Park J. .
Biomedical Engineering Letters, 2017, 7 (2) :115-120
[36]   MR compatible positioning device for guiding a focused ultrasound system for the treatment of brain deseases [J].
Mylonas, N. ;
Damianou, C. .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2014, 10 (01) :1-10
[37]   Magnetic resonance imaging-guided focused ultrasound for thermal ablation in the brain: A feasibility study in a swine model [J].
Cohen, Zvi R. ;
Zaubermann, Jacob ;
Harnof, Sagi ;
Mardor, Yael ;
Nass, Dvora ;
Zadicario, Eyal ;
Hananel, Arik ;
Castel, David ;
Faibel, Meir ;
Ram, Zvi .
NEUROSURGERY, 2007, 60 (04) :593-600
[38]   Clinical applications of focused ultrasound - The brain [J].
Hynynen, K. ;
Clement, G. .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2007, 23 (02) :193-202
[39]   Effects of acoustic parameters and ultrasound contrast agent dose on focused-ultrasound induced blood-brain barrier disruption [J].
Mcdannold, Nathan ;
Vykhodtseva, Natalia ;
Hynynen, Kullervo .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (06) :930-937
[40]   Focused ultrasound for blood-brain disruption and delivery of therapeutic molecules into the brain [J].
Hynynen, Kullervo .
EXPERT OPINION ON DRUG DELIVERY, 2007, 4 (01) :27-35