MRI detection of the thermal effects of focused ultrasound on the brain

被引:93
作者
Vykhodtseva, N
Sorrento, V
Jolesz, FA
Bronson, RT
Hynynen, K
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
[3] Tufts Univ, Sch Vet Med, Boston, MA 02111 USA
关键词
MRI; minimally invasive surgery; brain; focused ultrasound; ultrasound; thermal therapy; tissue ablation;
D O I
10.1016/S0301-5629(00)00216-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This study tested the hypothesis that MRI thermometry can be correlated with the different degrees of tissue damage observed after focused ultrasound (US) exposure of brain. The brains of 6 rabbits were sonicated to calibrate the MRI proton resonant shift with temperature, In addition, 13 rabbits were sonicated at acoustic powers ranging from 3.5 to 17.5 W. The experiments were performed in a 1.5-T MRI scanner with the temperature-sensitive phase imaging used during the sonications of 4-5 different locations in each rabbit. MR images mere obtained 2 h and 2 days after the sonications, depending on when the animals were sacrificed. Whole brain histologic evaluation was performed by sectioning the brain and performing a microscopic investigation. The MRI-derived temperature elevation was found to correlate well with the degree of tissue damage. In addition to the common histology findings, apoptotic cells were observed in the lesions, The T1-weighted contrast enhanced and T1-weighted scans both detected the brain damage. The applied acoustic power did not correlate well with the degree of damage. As a conclusion, the results showed that the measurement of temperature elevations by MRT during sonications can improve the accuracy and safety of clinical US brain surgery. (C) 2000 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:871 / 880
页数:10
相关论文
共 50 条
  • [21] Focused Ultrasound Surgery of the Brain
    Martin E.
    Werner B.
    Current Radiology Reports, 2013, 1 (2) : 126 - 135
  • [22] Imaging the premature brain: ultrasound or MRI?
    de Vries, Linda S.
    Benders, Manon J. N. L.
    Groenendaal, Floris
    NEURORADIOLOGY, 2013, 55 : 13 - 22
  • [23] Imaging the premature brain: ultrasound or MRI?
    Linda S. de Vries
    Manon J. N. L. Benders
    Floris Groenendaal
    Neuroradiology, 2013, 55 : 13 - 22
  • [24] The use of Optison to reduce the power requirements for focused ultrasound lesion production in the brain - An MRI/histology study in rabbits
    Vvkhodtseva, N
    McDannold, N
    Hynynen, K
    2004 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-3, 2004, : 1009 - 1012
  • [25] Development of an US, MRI, and CT imaging compatible realistic mouse phantom for thermal ablation and focused ultrasound evaluation
    Antoniou, Anastasia
    Nikolaou, Anastasia
    Georgiou, Andreas
    Evripidou, Nikolas
    Damianou, Christakis
    ULTRASONICS, 2023, 131
  • [26] MRI-guided focused ultrasound surgery of uterine leiomyomas
    Fennessy, FM
    Tempany, CM
    ACADEMIC RADIOLOGY, 2005, 12 (09) : 1158 - 1166
  • [27] High intensity focused ultrasound ablation of kidney guided by MRI
    Damianou, C
    Pavlou, M
    Velev, O
    Kyriakou, K
    Trimikliniotis, M
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (03) : 397 - 404
  • [28] MRI guided focused ultrasound robotic system for animal experiments
    Yiannakou, Marinos
    Menikou, Georgios
    Yiallouras, Christos
    Ioannides, Cleanthis
    Damianou, Christakis
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2017, 13 (04)
  • [29] Study of focused ultrasound tissue damage using MRI and histology
    Chen, L
    Bouley, D
    Yuh, E
    D'Arceuil, H
    Butts, K
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (02) : 146 - 153
  • [30] Review of MRI positioning devices for guiding focused ultrasound systems
    Yiallouras, C.
    Damianou, C.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2015, 11 (02) : 247 - 255