MRI detection of the thermal effects of focused ultrasound on the brain

被引:93
|
作者
Vykhodtseva, N
Sorrento, V
Jolesz, FA
Bronson, RT
Hynynen, K
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
[3] Tufts Univ, Sch Vet Med, Boston, MA 02111 USA
关键词
MRI; minimally invasive surgery; brain; focused ultrasound; ultrasound; thermal therapy; tissue ablation;
D O I
10.1016/S0301-5629(00)00216-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This study tested the hypothesis that MRI thermometry can be correlated with the different degrees of tissue damage observed after focused ultrasound (US) exposure of brain. The brains of 6 rabbits were sonicated to calibrate the MRI proton resonant shift with temperature, In addition, 13 rabbits were sonicated at acoustic powers ranging from 3.5 to 17.5 W. The experiments were performed in a 1.5-T MRI scanner with the temperature-sensitive phase imaging used during the sonications of 4-5 different locations in each rabbit. MR images mere obtained 2 h and 2 days after the sonications, depending on when the animals were sacrificed. Whole brain histologic evaluation was performed by sectioning the brain and performing a microscopic investigation. The MRI-derived temperature elevation was found to correlate well with the degree of tissue damage. In addition to the common histology findings, apoptotic cells were observed in the lesions, The T1-weighted contrast enhanced and T1-weighted scans both detected the brain damage. The applied acoustic power did not correlate well with the degree of damage. As a conclusion, the results showed that the measurement of temperature elevations by MRT during sonications can improve the accuracy and safety of clinical US brain surgery. (C) 2000 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:871 / 880
页数:10
相关论文
共 50 条
  • [1] MRI evaluation of thermal ablation of tumors with focused ultrasound
    McDannold, N
    Hynynen, K
    Wolf, D
    Wolf, G
    Jolesz, F
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01): : 91 - 100
  • [2] Thermal effects of focused ultrasound on the brain: Determination with MR imaging
    Hynynen, K
    Vykhodtseva, NI
    Chung, AH
    Sorrentino, V
    Colucci, V
    Jolesz, FA
    RADIOLOGY, 1997, 204 (01) : 247 - 253
  • [3] Effects of high intensity focused ultrasound on the brain
    Vykhodtseva, Natalia
    McDannold, Nathan
    Hynynen, Kullervo
    6TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2007, 911 : 535 - 541
  • [4] MRI-guided focused ultrasound treatments
    Hynynen, Kullervo
    ULTRASONICS, 2010, 50 (02) : 221 - 229
  • [5] MRI-based thermal dosimetry based on single-slice imaging during focused ultrasound thalamotomy
    McDannold, Nathan
    Jason White, P.
    Rees Cosgrove, G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23)
  • [6] Thermal ablation system using high intensity focused ultrasound (HIFU) and guided by MRI
    Damianou, C.
    Ioannides, K.
    HadjiSavas, V.
    Milonas, N.
    Couppis, A.
    Iosif, D.
    Komodromos, M.
    Vrionides, F.
    8TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2009, 1113 : 367 - +
  • [7] Future Potential of MRI-Guided Focused Ultrasound Brain Surgery
    Colen, Rivka R.
    Jolesz, Ferenc A.
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2010, 20 (03) : 355 - +
  • [8] Targeted drug delivery to the brain by MRI-guided focused ultrasound
    Treat, Lisa Hsu
    McDannold, Nathan
    Vykhodtseva, Natalia
    Zhang, Yongzhi
    Tam, Karen
    Hynynen, Kullervo
    THERAPEUTIC ULTRASOUND, 2006, 829 : 266 - +
  • [9] Thermal effects of focused ultrasound energy on bone tissue
    Smith, NB
    Temkin, JM
    Shapiro, F
    Hynynen, K
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (10) : 1427 - 1433
  • [10] Detection of near-surface defects in viscoelastic material based on focused ultrasound thermal effects
    Han, Mengyu
    Zheng, Huifeng
    Gao, Yumeng
    Zhou, Zhuangxin
    Liu, Xiangchen
    ULTRASONICS, 2024, 143