Capillary liquid chromatography/electrospray mass spectrometry for analysis of steroid sulfates in biological samples

被引:29
作者
Liu, S [1 ]
Griffiths, WJ [1 ]
Sjövall, J [1 ]
机构
[1] Karolinska Inst, Dept Med Biochem & Biophys, SE-17177 Stockholm, Sweden
关键词
D O I
10.1021/ac0262154
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new procedure for capillary liquid chromatography-electrospray (CLC-ES) mass spectrometry is described. Using this procedure, coupling of a CLC column to a low-flow-rate ES interface is made simple. A 5-cm precolumn and a 35-cm analytical column, both fused-silica capillaries with an i.d. of 100 mum and packed with 3-mum octadecylsilane-bonded material, are coupled in series to a sheathless ES emitter. One solvent splitter is positioned between the loop injector and the precolumn, and a second, between the precolumn and the analytical column. By opening and closing the splitters in the appropriate order, this arrangement permits the injection of 1-20 muL of sample solution with analyte focusing onto the top of the precolumn, followed by isocratic or gradient elution at a flow rate of 0.2-0.3 muL/min through the analytical column. The relative standard deviation of the retention times of reference compounds was <3.5% (n = 5). The potential of the system in metabolome analysis, in which numerous isomeric compounds will require identification, is illustrated by the application of the system to the analysis of steroid sulfates in plasma.
引用
收藏
页码:791 / 797
页数:7
相关论文
共 34 条
[1]  
Abian J, 1999, J MASS SPECTROM, V34, P244, DOI 10.1002/(SICI)1096-9888(199904)34:4<244::AID-JMS775>3.0.CO
[2]  
2-0
[3]   DIRECT COUPLING OF PACKED FUSED-SILICA LIQUID-CHROMATOGRAPHIC COLUMNS TO A MAGNETIC-SECTOR MASS-SPECTROMETER AND APPLICATION TO POLAR THERMOLABILE COMPOUNDS [J].
ALBORN, H ;
STENHAGEN, G .
JOURNAL OF CHROMATOGRAPHY, 1985, 323 (01) :47-66
[4]   Evaluation of automated isocratic and gradient nano-liquid chromatography and capillary electrochromatography [J].
Alexander, JN ;
Poli, JB ;
Markides, KE .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2398-2409
[5]   STABLE ISOTOPE STUDIES ON STEROID-METABOLISM AND KINETICS - SULFATES OF 3-ALPHA-HYDROXY-5-ALPHA-PREGNANE DERIVATIVES IN HUMAN-PREGNANCY [J].
ANDERSON, RA ;
BAILLIE, TA ;
AXELSON, M ;
CRONHOLM, T ;
SJOVALL, K ;
SJOVALL, J .
STEROIDS, 1990, 55 (10) :443-457
[6]   MICRO-ELECTROSPRAY - ZEPTOMOLE-ATTOMOLE PER MICROLITER SENSITIVITY FOR PEPTIDES [J].
ANDREN, PE ;
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (09) :867-869
[7]   Micro-SPE method for sample introduction in capillary HPLC/MS [J].
Cappiello, A ;
Berloni, A ;
Famiglini, G ;
Mangani, F ;
Palma, P .
ANALYTICAL CHEMISTRY, 2001, 73 (02) :298-302
[8]   Instrumental requirements for nanoscale liquid chromatography [J].
Chervet, JP ;
Ursem, M ;
Salzmann, JB .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1507-1512
[9]  
Devreese B, 2001, RAPID COMMUN MASS SP, V15, P50, DOI 10.1002/1097-0231(20010115)15:1<50::AID-RCM191>3.0.CO
[10]  
2-V