Multiplex bead array assays for detection of soluble cytokines: Comparisons of sensitivity and quantitative values among kits from multiple manufacturers

被引:291
作者
Khan, SS
Smith, MS
Reda, D
Suffredini, AF
McCoy, JP
机构
[1] NHLBI, NIH, Flow Cytometry Core, Bethesda, MD 20892 USA
[2] NIH, Warren G Magnuson Clin Ctr, Dept Crit Care Med, Bethesda, MD 20892 USA
关键词
luminex; multiplex bead array; cytokines;
D O I
10.1002/cyto.b.20021
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Multiplex bead array assays permit simultaneous cytometric quantitation of multiple cytokines in solution by capturing these to spectrally distinct beads. Because several manufacturers offer reagents to quantitate the same cytokines on a single instrument, a comparison should be made to determine whether these kits yield similar data and whether these data are comparable to enzyme-linked immunosorbent assay (ELISA). Methods: This study compared cytokine detection kits by using Luminex 100. Twenty-six serum samples from seven subjects were analyzed for interferon-gamma, interleukins 1beta, 6, and 8, and tumor necrosis factor-a by using multiplex kits from LINCO Research, Bio-Rad Laboratories, R&D Systems, and BioSource International. Each assay was performed according to the manufacturers' specifications. Standard curves were generated by using reference concentrations supplied by each manufacturer. ELISAs for interleukin-8 were performed by using kits from R&D and BioSource. Results: Cytokine levels followed similar patterns, although absolute concentrations differed among kits. ELISA and Luminex values for interleukin-8 were similar in kits from the same manufacturer. Conclusions: Because relative cytokine measurements are often valuable when performed serially, it may be possible to make interlaboratory comparisons by using different kits. When comparison of absolute values is crucial, kits from the same supplier should be used. Within-vendor, bead array, and ELISA values appear comparable. Published 2004 Wiley-Liss, Inc.(dagger)
引用
收藏
页码:35 / 39
页数:5
相关论文
共 14 条
  • [1] Simultaneous detection of 15 human cytokines in a single sample of stimulated peripheral blood mononuclear cells
    de Jager, W
    te Velthuis, H
    Prakken, BJ
    Kuis, W
    Rijkers, GT
    [J]. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2003, 10 (01) : 133 - 139
  • [2] Quantitative, multiplexed detection of bacterial pathogens:: DNA and protein applications of the Luminex LabMAP™ system
    Dunbar, SA
    Vander Zee, CA
    Oliver, KG
    Karem, KL
    Jacobson, JW
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2003, 53 (02) : 245 - 252
  • [3] Human models of innate immunity: local and systemic inflammatory responses
    Fiuza, C
    Suffredini, AF
    [J]. JOURNAL OF ENDOTOXIN RESEARCH, 2001, 7 (05): : 385 - 388
  • [4] Cytokines as mediators for or effectors against rotavirus disease in children
    Jiang, B
    Snipes-Magaldi, L
    Dennehy, P
    Keyserling, H
    Holman, RC
    Bresee, J
    Gentsch, J
    Glass, RI
    [J]. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2003, 10 (06) : 995 - 1001
  • [5] Circulating angiogenic growth factor levels in mice bearing human tumors using Luminex Multiplex technology
    Kristan, KA
    Mann, L
    Cox, K
    Treadway, P
    Iversen, P
    Chen, YF
    Teicher, BA
    [J]. CANCER CHEMOTHERAPY AND PHARMACOLOGY, 2003, 51 (04) : 321 - 327
  • [6] Mandy FF, 2001, CLIN LAB MED, V21, P713
  • [7] Martins TB, 2002, AM J CLIN PATHOL, V118, P346
  • [8] Nolan JP, 2001, CELL MOL BIOL, V47, P1241
  • [9] Comparison of a multiplex flow cytometric assay with enzyme-linked immunosorbent assay for quantitation of antibodies to tetanus, diphtheria, and Haemophilus influenzae type b
    Pickering, JW
    Martins, TB
    Schroder, MC
    Hill, HR
    [J]. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2002, 9 (04) : 872 - 876
  • [10] Simultaneous quantification of proinflammatory cytokines in human plasma using the LabMAP™ assay
    Prabhakar, U
    Eirikis, E
    Davis, HM
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 260 (1-2) : 207 - 218