New technologies for measuring intraocular pressure

被引:14
|
作者
Garcia-Feijoo, Julian [1 ,2 ]
Martinez-de-la-Casa, Jose Maria [1 ,2 ]
Morales-Fernandez, Laura [1 ,2 ]
Frances, Federico Saenz [1 ,2 ]
Santos-Bueso, Enrique [1 ,2 ]
Garcia-Saenz, Sofia [1 ,2 ]
Mendez-Hernandez, Carmen [1 ,2 ]
机构
[1] Univ Complutense Madrid, Inst Invest Sanitaria Hosp Clin San Carlos IdISSC, Hosp Clin San Carlos, Dept Oftalmol & ORL,Fac Med,Serv Oftalmol, Madrid, Spain
[2] Inst Salud Carlos III, Cooperat Res Network Age Related Ocular Pathol Vi, Madrid, Spain
来源
NEW TRENDS IN BASIC AND CLINICAL RESEARCH OF GLAUCOMA: A NEURODEGENERATIVE DISEASE OF THE VISUAL SYSTEM, PT B | 2015年 / 221卷
关键词
Intraocular pressure; Tonometer; Goldmann; Corneal thickness; Corneal hysteresis; Dynamic contour; Pascal; Corvis; Ocular response analyzer; ICare; Rebound; Sensimed; GOLDMANN APPLANATION TONOMETRY; OCULAR HYPERTENSION TREATMENT; DYNAMIC CONTOUR TONOMETRY; CORNEAL THICKNESS; REBOUND TONOMETER; ICARE; NONCONTACT; TGDC-01; ONSET;
D O I
10.1016/bs.pbr.2015.06.003
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The level of intraocular pressure (IOP) is the main known risk factor for the development and progression of glaucomatous optic neuropathy. Despite Goldmann applanation tonometry (GAT) being the gold standard for determining IOP since the last century, its limitations were obvious from the start and include substantial effects of several eye variables such as axial length, curvature, rigidity, and corneal thickness. These limitations have prompted the development of numerous formulas and nomograms designed to compensate for the ocular characteristics effect on GAT, but none of these methods has been entirely satisfactory. Similarly, as a result of efforts to mitigate some of the limitations of conventional tonometry, several new tonometers have appeared on the scene.
引用
收藏
页码:67 / 79
页数:13
相关论文
共 50 条
  • [21] Intraocular pressure measurement: A review *
    Da Silva, Filipe
    Lira, Madalena
    SURVEY OF OPHTHALMOLOGY, 2022, 67 (05) : 1319 - 1331
  • [22] Techniques of Intraocular Pressure Measurement
    Neuburger, M.
    Rosentreter, A.
    Dietlein, T. S.
    Jordan, J. F.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2011, 228 (02) : 118 - 124
  • [23] Intraocular Pressure Measurements After Descemet Membrane Endothelial Keratoplasty
    Maier, Anna-Karina
    Gundlach, Enken
    Pahlitzsch, Milena
    Gonnermann, Johannes
    Corkhill, Caitlin
    Bertelmann, Eckart
    Joussen, Antonia M.
    Klamann, Matthias K. J.
    Torun, Necip
    JOURNAL OF GLAUCOMA, 2017, 26 (03) : 258 - 265
  • [24] Hornhautdickenunabhängige Methoden der Messung des AugeninnendrucksMethods of measuring intraocular pressure independently of central corneal thickness
    A. Hager
    W. Wiegand
    Der Ophthalmologe, 2008, 105 : 840 - 844
  • [25] Evaluation of the Icare-ONE rebound tonometer as a self-measuring intraocular pressure device in normal subjects
    Halkiadakis, Ioannis
    Stratos, Aimilianos
    Stergiopoulos, George
    Patsea, Eleni
    Skouriotis, Sotiris
    Mitropoulos, Panagiotis
    Papaconstantinou, Dimitrios
    Georgopoulos, Gerasimos
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (08) : 1207 - 1211
  • [26] Intraocular pressure (IOP) measurements in keratoconic patients: Do variations in IOP respect variations in corneal thickness and corneal curvature?
    Cairns, Rebecca
    Graham, Katie
    O'Gallagher, Michael
    Jackson, A. Jonathan
    CONTACT LENS & ANTERIOR EYE, 2019, 42 (02) : 216 - 219
  • [27] Evaluation of the ICare Rebound Tonometer as a Home Intraocular Pressure Monitoring Device
    Asrani, Sanjay
    Chatterjee, Ashmita
    Wallace, David K.
    Santiago-Turla, Cecilia
    Stinnett, Sandra
    JOURNAL OF GLAUCOMA, 2011, 20 (02) : 74 - 79
  • [28] Intraocular pressure and ocular pulse amplitude variations during the Valsalva maneuver
    Aykan, Umit
    Erdurmus, Mesut
    Yilmaz, Burhan
    Bilge, Ahmet Hamdi
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (08) : 1183 - 1186
  • [29] The effect of caffeine on intraocular pressure: a systematic review and meta-analysis
    Li, Mao
    Wang, Min
    Guo, Wenyi
    Wang, Jiajian
    Sun, Xinghuai
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (03) : 435 - 442
  • [30] Design and Simulation of New Micro-Electromechanical Pressure Sensor for Measuring Intraocular Pressure
    Shahiri-Tabarestani, M.
    Ganji, B. A.
    Sabbaghi-Nadooshan, R.
    2012 16TH IEEE MEDITERRANEAN ELECTROTECHNICAL CONFERENCE (MELECON), 2012, : 208 - 211