In-field measurements of PCDD/F emissions from domestic heating appliances for solid fuels

被引:21
作者
Hübner, C [1 ]
Boos, R [1 ]
Prey, T [1 ]
机构
[1] FTU, A-1210 Vienna, Austria
关键词
PCDD/F; solid fuel; emission factor; single stove; heating boiler; domestic heating appliances;
D O I
10.1016/S0045-6535(03)00702-1
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Within this project the emissions into the atmosphere of polychlorinated dibenzo-p-dioxins and -furans (PCDD/F) of 30 domestic heating appliances in Austrian households were tested. The appliances were single stoves (kitchen stove, continuous burning stove and tiled stove) and central heating boilers for solid fuels up to a nominal heat input of 50 kW. A main objective of this survey was to determine the PCDD/F emissions of domestic heating units under routine conditions. Therefore, the habitual combustion conditions used by the operators were not influenced. The original fuels and lightning supports were used and the operation of the units was carried out by the householders according to their usual practice. The data obtained were used to calculate in-field PCDD/F-emission factors. Most of the appliances have shown PCDD/F emissions within a concentration range of 0.01-0.3 ng TEQ/MJ. Modern fan-assisted wood heating boilers with afterburning and units for continuously burning of wood chips and wood pellets had the lowest emissions. High emissions were caused by unsuitable heating habits such as combustion of wastes and inappropriate operation of the appliances. There were only small differences between single stoves and central heating boilers or between wood and coal-fired appliances. The emission factors calculated are higher than those cited in literature, which are mainly derived from trials on test stands under laboratory conditions. (C) 2003 Published by Elsevier Ltd.
引用
收藏
页码:367 / 372
页数:6
相关论文
共 10 条
[1]  
BROKER G, 1992, 103 LIS NRW
[2]  
Ellinger R, 2002, GEFAHRST REINHALT L, V62, P381
[3]  
*GERM FED ENV AG, 1996, UBAFB96082 GERM FED
[4]  
*GERM FED ENV AG, 1998, 98115 UBAFB GERM FED
[5]  
HUBNER C, 2001, OSTERREICHISCHE EMIS
[6]   PCDD/F- and PAH-emission from house heating systems [J].
Launhardt, T ;
Strehler, A ;
Dumler-Gradl, R ;
Thoma, H ;
Vierle, O .
CHEMOSPHERE, 1998, 37 (9-12) :2013-2020
[7]  
PFEIFFER F, 2000, ERMITTLUNG MITTLEREN
[8]  
QUASS U, 1997, 43 LUA NRW
[9]  
SPTIZER J, 1998, IEFB0798
[10]  
WURST F, 1997, ERHEBUNG PCDD F EMIS