The effect of a shock-absorbing pylon on the gait of persons with unilateral transtibial amputation

被引:49
作者
Gard, SA
Konz, RJ
机构
[1] Northwestern Univ, Prosthet Res Lab, Dept Phys Med & Rehabil, Feinberg Sch Med, Chicago, IL 60611 USA
[2] Northwestern Univ, Rehabil Engn Res Program, Dept Phys Med & Rehabil, Feinberg Sch Med, Chicago, IL 60611 USA
[3] Dept Vet Affairs Chicago Hlth Care Syst, Lakeside Div, Chicago, IL USA
[4] Northwestern Univ, Dept Biomed Engn, Evanston, IL 60208 USA
关键词
gait; prosthetics; shock-absorbing pylon; shock absorption; transtibial amputee;
D O I
10.1682/JRRD.2003.03.0109
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Shock-absorbing pylons (SAPs) are components that increase prosthetic compliance and provide shock absorption during walking, running, and other high-impact activities in persons with leg amputations. This study investigated the effect of SAPs on the gaits of persons who walk with transtibial prostheses. Two gait analyses were performed on 10 subjects walking with and without an Endolite TT (Telescopic-Torsion) Pylon. Comparison of kinematic and kinetic gait parameters indicated that few quantitative changes were found in the way people walked with and without the SAPs. The most consistent change among subjects was a reduction in the magnitude of an isolated-force transient that occurred during the prosthetic loading response phase, an effect that was more evident at higher speeds. Results from a questionnaire that was administered to subjects indicated they generally preferred walking with the SAP for reasons related to comfort. We conclude that SAPs may provide significant benefit for persons with transtibial amputations who are able to routinely walk at speeds above approximately 1.3 m/s.
引用
收藏
页码:109 / 124
页数:16
相关论文
共 40 条
[1]  
Bowker J.H., 1975, Atlas of Orthotics: Biomechanical Principles and Application, Chapter 7 in the American Academy of Orthopaedic Surgeons, P133
[2]  
Bowker J.H., 1981, Atlas of Limb Prosthetics: Surgical and Prosthetic Principles, Chapter 18 in the American Academy of Orthopaedic Surgeons, P261
[3]  
Cappozzo A., 1991, ADAPTABILITY HUMAN G, P167
[4]   IMPULSIVE FORCES DURING WALKING AND THEIR CLINICAL IMPLICATIONS [J].
COLLINS, JJ ;
WHITTLE, MW .
CLINICAL BIOMECHANICS, 1989, 4 (03) :179-187
[5]   PROSTHETIC FEET - STATE OF THE ART [J].
EDELSTEIN, JE .
PHYSICAL THERAPY, 1988, 68 (12) :1874-1881
[6]   The effect of pelvic list on the vertical displacement of the trunk during normal walking [J].
Gard, SA ;
Childress, DS .
GAIT & POSTURE, 1997, 5 (03) :233-238
[7]   The influence of stance-phase knee flexion on the vertical displacement of the trunk during normal walking [J].
Gard, SA ;
Childress, DS .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (01) :26-32
[8]   BIOMECHANICAL ANALYSIS OF THE INFLUENCE OF PROSTHETIC FEET ON BELOW-KNEE AMPUTEE WALKING [J].
GITTER, A ;
CZERNIECKI, JM ;
DEGROOT, DM .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1991, 70 (03) :142-148
[9]   REFLEX STIFFNESS OF MANS ANTI-GRAVITY MUSCLES DURING KNEEBENDS WHILE CARRYING EXTRA WEIGHTS [J].
GREENE, PR ;
MCMAHON, TA .
JOURNAL OF BIOMECHANICS, 1979, 12 (12) :881-891
[10]   Physiological measurements of walking and running in people with transtibial amputations with 3 different prostheses [J].
Hsu, MJ ;
Nielsen, DH ;
Yack, HJ ;
Shurr, DG .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1999, 29 (09) :526-533