Bienzymatic amperometric biosensor for choline based on mediator thionine in situ electropolymerized within a carbon paste electrode

被引:65
作者
Yang, MH [1 ]
Yang, YH [1 ]
Yang, Y [1 ]
Shen, GL [1 ]
Yu, RQ [1 ]
机构
[1] Hunan Univ, State Key Lab Chemo Biosensing & Chemometr, Chem & Chem Engn Coll, Changsha 410082, Peoples R China
基金
中国国家自然科学基金;
关键词
biosensor; choline; in situ electropolymerization; chitosan; phosphatidylcholine;
D O I
10.1016/j.ab.2004.07.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An amperometric enzyme biosensor for the determination of choline utilizing two enzymes, choline oxidase (CHOD) and horseradish peroxidase (HRP), is described. The biosensor consisted of CHOD cross-linked onto a HRP-immobilized carbon paste electrode. The biosensor was prepared by in situ electropolymerization of poly(thionine) within a carbon paste containing the enzyme HRP and thionine monomer and then CHOD was immobilized by using chitosan film through cross-linking with glutaraldehyde. The in situ electrogenerated poly(thionine) displays excellent electron transform efficiency between the enzyme HRP and the electrode surface, and the polymer enables improvement in enzyme immobilization within the paste. Several parameters such as the amount of thionine and enzyme, the applied potential, the pH, etc. have been Studied. Amperometric detection of choline was realized at an applied potential of -0.2 V vs saturated calomel electrode in 1/15 M phosphate buffer solution (pH 7.4) with a linear response range between 5.0 x 10(-6) and 6.0 x 10(-4) M choline and a response time of 15 s. When applied to the analysis of phosphatidylcholine in serum samples, a 0.997 correlation was obtained between the biosensor results and those obtained by a hospital method. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:127 / 134
页数:8
相关论文
共 28 条
  • [11] ELECTRON-TRANSFER FROM NADH DEHYDROGENASE TO POLYPYRROLE AND ITS APPLICABILITY TO ELECTROCHEMICAL OXIDATION OF NADH
    MATSUE, T
    KASAI, N
    NARUMI, M
    NISHIZAWA, M
    YAMADA, H
    UCHIDA, I
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 300 (1-2): : 111 - 118
  • [12] Unusual response in mediated biosensors with an oxidase/peroxidase bienzyme system
    Matsumoto, R
    Mochizuki, M
    Kano, K
    Ikeda, T
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (14) : 3297 - 3303
  • [13] Acetylcholine and choline amperometric enzyme sensors characterized in vitro and in vivo
    Mitchell, KM
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (04) : 1098 - 1106
  • [14] Electrochemical oxidation of cholesterol catalyzed by cholesterol oxidase with use of an artificial electron mediator
    Nakaminami, T
    Kuwabata, S
    Yoneyama, H
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (13) : 2367 - 2372
  • [15] Studies on the electrochemical performance of glucose biosensor based on ferrocene encapsulated ORMOSIL and glucose oxidase modified graphite paste electrode
    Pandey, PC
    Upadhyay, S
    Shukla, NK
    Sharma, S
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (10) : 1257 - 1268
  • [16] Graphite-teflon composite bienzyme electrodes for the determination of cholesterol in reversed micelles.: Application to food samples
    Peña, N
    Ruiz, G
    Reviejo, AJ
    Pingarrón, JM
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (06) : 1190 - 1195
  • [17] Disposable interference-free glucose biosensor based on an electropolymerised poly(pyrrole) permselective film
    Quinto, M
    Losito, I
    Palmisano, F
    Zambonin, CG
    [J]. ANALYTICA CHIMICA ACTA, 2000, 420 (01) : 9 - 17
  • [18] Reagentless enzyme electrode based on phenothiazine mediation of horseradish peroxidase for subnanomolar hydrogen peroxide determination
    Razola, SS
    Aktas, E
    Viré, JC
    Kauffmann, JM
    [J]. ANALYST, 2000, 125 (01) : 79 - 85
  • [19] Amperometric determination of choline released from rat submandibular gland acinar cells using a choline oxidase biosensor
    Razola, SS
    Pochet, S
    Grosfils, K
    Kauffmann, JM
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3) : 185 - 191
  • [20] Thionine covalently tethered to multilayer horseradish peroxidase in a self-assembled monolayer as an electron-transfer mediator
    Ruan, CM
    Yang, F
    Lei, CH
    Deng, JQ
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (09) : 1721 - 1725