On the multiple microphone method for measuring in-duct acoustic properties in the presence of mean flow

被引:117
|
作者
Jang, SH [1 ]
Ih, JG [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Mech Engn, Ctr Noise & Vibrat Control, Taejon 305701, South Korea
来源
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA | 1998年 / 103卷 / 03期
关键词
D O I
10.1121/1.421289
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Nowadays, the two-microphone method is accepted as the standard as specified in ASTM E1050-90 for measuring in-duct acoustic properties. However, research results on using the least square method with multiple measurement points and broadband excitation have been reported for enhancing the frequency response of the two-microphone method. In this paper, the effects of varying the relative measurement positions on errors in the: estimation of the acoustic quantities is studied for the multiple microphone method. Both the theoretical and experimental results show that, among possible sensor positioning configurations, the equidistant positioning of sensors yields the smallest error within the effective measurement frequency range. In addition, it is noted that the measurement accuracy can be increased and the effective frequency range can be widened by increasing the number of equidistant sensors. Measurement examples are shown and the results support the findings. (C) 1998 Acoustical Society of America.
引用
收藏
页码:1520 / 1526
页数:7
相关论文
共 50 条
  • [1] Measurement of in-duct acoustic properties by using a single microphone with fixed position
    Choy, YS
    Huang, LX
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 116 (06): : 3498 - 3504
  • [2] TRANSFER-FUNCTION METHOD OF MEASURING IN-DUCT ACOUSTIC PROPERTIES .2. EXPERIMENT
    CHUNG, JY
    BLASER, DA
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1980, 68 (03): : 914 - 921
  • [3] TRANSFER-FUNCTION METHOD OF MEASURING IN-DUCT ACOUSTIC PROPERTIES .1. THEORY
    CHUNG, JY
    BLASER, DA
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1980, 68 (03): : 907 - 913
  • [4] Indirect calibration of a large microphone array for in-duct acoustic measurements
    Leclere, Q.
    Pereira, A.
    Finez, A.
    Souchotte, P.
    JOURNAL OF SOUND AND VIBRATION, 2016, 376 : 48 - 59
  • [5] Acoustic imaging of a duct spinning mode by the use of an in-duct circular microphone array
    Wei, Qingkai
    Huang, Xun
    Peers, Edward
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2013, 133 (06): : 3986 - 3994
  • [6] PREDICTING THE EFFECT OF FLOW DISTORTION ON IN-DUCT ACOUSTIC PROPAGATION
    Prinn, Albert
    Astley, Jeremy
    Sugimoto, Rie
    PROCEEDINGS OF THE 22ND INTERNATIONAL CONGRESS ON SOUND AND VIBRATION: MAJOR CHALLENGES IN ACOUSTICS, NOISE AND VIBRATION RESEARCH, 2015, 2015,
  • [7] Measurement of in-duct acoustic properties using three microphones
    Ih, JG
    Jang, SH
    Kim, BK
    PROCEEDINGS OF NOISE-CON 96 - THE 1996 NATIONAL CONFERENCE ON NOISE CONTROL ENGINEERING, VOLS 1 AND 2, 1996, : 727 - 730
  • [8] Prediction of flow-generated noise produced by acoustic and aerodynamic interactions of multiple in-duct elements
    Han, Ning
    Mak, C. M.
    APPLIED ACOUSTICS, 2008, 69 (06) : 566 - 573
  • [9] THE 2-MICROPHONE METHOD INCORPORATING THE EFFECTS OF MEAN FLOW AND ACOUSTIC DAMPING
    MUNJAL, ML
    DOIGE, AG
    JOURNAL OF SOUND AND VIBRATION, 1990, 137 (01) : 135 - 138
  • [10] Flow effects on the acoustic end correction of a sudden in-duct area expansion
    Boij, Susann
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2009, 126 (03): : 995 - 1004