Methods of determining the effective dose in dental radiology

被引:23
作者
Thilander-Klang, Anne [1 ,2 ]
Helmrot, Ebba [3 ,4 ]
机构
[1] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, SE-41345 Gothenburg, Sweden
[2] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Radiat Phys, SE-41345 Gothenburg, Sweden
[3] Linkoping Univ Hosp, Dept Med & Hlth Sci, Div Radiol Sci, SE-58185 Linkoping, Sweden
[4] Linkoping Univ Hosp, Dept Radiat Phys, SE-58185 Linkoping, Sweden
关键词
CONE-BEAM CT; CONVERSION COEFFICIENTS; DOSIMETRY; PATIENT; DEVICES;
D O I
10.1093/rpd/ncq081
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A wide variety of X-ray equipment is used today in dental radiology, including intra-oral, orthopantomographic, cephalometric, cone-beam computed tomography (CBCT) and computed tomography (CT). This raises the question of how the radiation risks resulting from different kinds of examinations should be compared. The risk to the patient is usually expressed in terms of effective dose. However, it is difficult to determine its reliability, and it is difficult to make comparisons, especially when different modalities are used. The classification of the new CBCT units is also problematic as they are sometimes classified as CT units. This will lead to problems in choosing the best dosimetric method, especially when the examination geometry resembles more on an ordinary orthopantomographic examination, as the axis of rotation is not at the centre of the patient, and small radiation field sizes are used. The purpose of this study was to present different methods for the estimation of the effective dose from the equipment currently used in dental radiology, and to discuss their limitations. The methods are compared based on commonly used measurable and computable dose quantities, and their reliability in the estimation of the effective dose.
引用
收藏
页码:306 / 309
页数:4
相关论文
共 31 条
  • [1] [Anonymous], STUKA231 FINN CTR RA
  • [2] ENERGY IMPARTED TO THE PATIENT IN DIAGNOSTIC-RADIOLOGY - CALCULATION OF CONVERSION FACTORS FOR DETERMINING THE ENERGY IMPARTED FROM MEASUREMENTS OF THE AIR COLLISION KERMA INTEGRATED OVER BEAM AREA
    CARLSSON, GA
    CARLSSON, CA
    PERSLIDEN, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (11) : 1329 - 1341
  • [3] Ekestubbe A, 1992, Dentomaxillofac Radiol, V21, P65
  • [4] *EUR COMM, 2000, 16262 EUR COMM
  • [5] *EUR COMM RAD PROT, 2004, 136 EUR COMM RAD PRO
  • [6] Dosimetry of digital panoramic imaging. Part I: patient exposure
    Gijbels, F
    Jacobs, R
    Bogaerts, R
    Debaveye, D
    Verlinden, S
    Sanderink, G
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2005, 34 (03) : 145 - 149
  • [7] On the uncertainties in effective dose estimates of adult CT head scans
    Gregory, Kent J.
    Bibbo, Giovanni
    Pattison, John E.
    [J]. MEDICAL PHYSICS, 2008, 35 (08) : 3501 - 3510
  • [8] Uncertainties in effective dose estimates of adult CT head scans: The effect of head size
    Gregory, Kent J.
    Bibbo, Giovanni
    Pattison, John E.
    [J]. MEDICAL PHYSICS, 2009, 36 (09) : 4121 - 4125
  • [9] Measurement of radiation dose in dental radiology
    Helmrot, E
    Carlsson, GA
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 168 - 171
  • [10] HELMROT E, 1996, THESIS LINKOPING U