Polymer analysis by micro-scale size exclusion chromatography MALDI time-of-flight mass spectrometry with a robotic interface

被引:60
作者
Nielen, MWF [1 ]
机构
[1] Akzo Nobel Cent Res, Gen Analyt & Environm Chem Dept, NL-6800 SB Arnhem, Netherlands
关键词
D O I
10.1021/ac9712409
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polydisperse synthetic polymers cannot be characterized reliably by matrix-assisted laser desorption/ionization time-of-night mass spectrometry (MALDI MS) alone. Coupling of size-exclusion chromatography (SEC) with MALDI MS provides both absolute mass calibration of the SEC column based on the polymer itself and determination of monomers and end groups from the mass spectra. Now a micro-scale SEC (mu SEC) system has been developed in which the MALDI matrix solution is coaxially added to the column effluent and directly spotted onto the MALDI targets in a robotic interface. Each spot corresponds with a 10-s elution window from the mu SEC column, thus yielding a narrow polymer distribution which is amenable to characterization by MALDI MS. This mu SEC/MALDI MS system is less laborious and time-consuming and features very low solvent consumption and reduced solvent emission during the evaporation step as compared to the conventional-sized SEC/fraction collector systems applied in the past. The performance is demonstrated by the characterization of a polybisphenol A carbonate and a complex dipropoxylated bisphenol A/adipic acid/isophthalic acid copolyester resin.
引用
收藏
页码:1563 / 1568
页数:6
相关论文
共 33 条
[1]  
AASERUD DJ, 1997, P 45 ASMS C MASS SPE, P1283
[2]   Mass discrimination effects in an ion detector and other causes for shifts in polymer mass distributions measured by matrix-assisted laser desorption ionization time-of-flight mass spectrometry [J].
Axelsson, J ;
Scrivener, E ;
Haddleton, DM ;
Derrick, PJ .
MACROMOLECULES, 1996, 29 (27) :8875-8882
[3]   MICROCOLUMN SIZE-EXCLUSION CHROMATOGRAPHY WITH POLYMERIC STATIONARY PHASES [J].
CORTES, HJ ;
PFEIFFER, CD .
ANALYTICAL CHEMISTRY, 1993, 65 (10) :1476-1480
[4]  
DANIS PO, 1996, POLYM PREPR, V37, P311
[5]  
Dogruel D, 1996, RAPID COMMUN MASS SP, V10, P801
[6]  
DWYER J, 1996, AM LAB, P51
[7]   On-line coupling of gel permeation chromatography with MALDI mass spectrometry [J].
Fei, X ;
Murray, KK .
ANALYTICAL CHEMISTRY, 1996, 68 (20) :3555-3560
[8]  
Garozzo D, 1995, RAPID COMMUN MASS SP, V9, P937
[9]   Time-lag focusing and cation attachment in the analysis of synthetic polymers by matrix-assisted laser desorption ionization-time-of-flight mass spectrometry [J].
Jackson, AT ;
Yates, HT ;
MacDonald, WA ;
Scrivens, JH ;
Critchley, G ;
Brown, J ;
Deery, MJ ;
Jennings, KR ;
Brookes, C .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (02) :132-139
[10]   Comparison of most probable peak values as measured for polymer distributions by MALDI mass spectrometry and by size exclusion chromatography [J].
Jackson, C ;
Larsen, B ;
McEwen, C .