Outcomes of patients treated with ultrathin-strut biodegradable polymer sirolimus-eluting stents versus fluoropolymer-based everolimus-eluting stents: a meta- analysis of randomised trials

被引:16
作者
Cassese, Salvatore [1 ]
Ndrepepa, Gjin [1 ]
Byrne, Robert A. [1 ]
Kufner, Sebastian [1 ]
Lahmann, Anna Lena [1 ]
Mankerious, Nader [1 ]
Xhepa, Erion [1 ]
Laugwitz, Karl-Ludwig [2 ,3 ]
Schunkert, Heribert [1 ,3 ]
Fusaro, Massimiliano [1 ]
Kastrati, Adnan [1 ,3 ]
Joner, Michael [1 ,3 ]
机构
[1] Tech Univ Munich, Deutsch Herzzentrum Munchen, Lazarettstr 36, D-80636 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Med Klin & Poliklin 1, Munich, Germany
[3] DZHK German Ctr Cardiovasc Res, Partner Site Munich Heart Alliance, Munich, Germany
关键词
clinical research; clinical trials; drug-eluting stent; DURABLE POLYMER; CLINICAL-TRIALS; METAANALYSIS; THROMBOSIS; PERMANENT; COATINGS; THIN;
D O I
10.4244/EIJ-D-18-00024
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The ultrathin-strut biodegradable polymer sirolimus-eluting stent (SES) is a new-generation drug-eluting stent (DES) developed to improve the percutaneous treatment of patients with coronary artery disease. Here, we sought to investigate whether the performance of the ultrathin-strut biodegradable polymer SES is superior to that of the benchmark thin-strut fluoropolymer-based everolimus-eluting stent (EES). Methods and results: We undertook a study-level meta-analysis of trials in which patients receiving percutaneous coronary intervention (PCI) were randomly assigned to either SES or EES. Primary efficacy and safety outcomes were target lesion revascularisation (TLR) and defmite/probable stent thrombosis (ST), respectively. Secondary outcomes were myocardial infarction (MI), death, target lesion failure (TLF) and target vessel failure (TVF). A total of 4,853 patients received a PCI with either SES (n=2,816) or EES (n=2,037) in six trials. After a weighted median follow-up of 12 months, patients treated with SES had a risk of TLR (odds ratio [95% confidence interval]: 1.24 [0.83-1.85], p=0.30), defmite/probable ST (0.84 [0.53-1.33], p=0.45) and MI related to the target vessel (0.77 [0.55-1.07], p=0.12) comparable to that of patients treated with EES. We found no significant difference with regard to other secondary outcomes. Conclusions: At one-year follow-up, the ultrathin-strut biodegradable polymer sirolimus-eluting stent displays a performance comparable to that of the fluoropolymer-based everolimus-eluting stent.
引用
收藏
页码:224 / 231
页数:8
相关论文
共 50 条
[31]   Clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents versus durable polymer everolimus-eluting Xience stents [J].
Lee, Da Hyon ;
Park, Taek Kyu ;
Bin Song, Young ;
Chun, Woo Jung ;
Choi, Rak Kyeong ;
Jeong, Jin-Ok ;
Im, Eul Soon ;
Kim, Sang Wook ;
Lee, Joo Myung ;
Yang, Jeong Hoon ;
Hahn, Joo-Yong ;
Choi, Seung-Hyuk ;
Choi, Jin-Ho ;
Lee, Sang Hoon ;
Gwon, Hyeon-Cheol .
PLOS ONE, 2017, 12 (08)
[32]   Very thin strut biodegradable polymer everolimus-eluting and sirolimus-eluting stents versus durable polymer zotarolimus-eluting stents in allcomers with coronary artery disease (BIO-RESORT): a three-arm, randomised, non-inferiority trial [J].
von Birgelen, Clemens ;
Kok, Marlies M. ;
van der Heijden, Liefke C. ;
Danse, Peter W. ;
Schotborgh, Carl E. ;
Scholte, Martijn ;
Gin, R. Melvyn Tjon Joe ;
Somi, Samer ;
van Houwelingen, K. G. ;
Stoel, M. G. ;
de Man, Frits H. A. F. ;
Louwerenburg, J. W. ;
Hartmann, Marc ;
Zocca, Paolo ;
Linssen, Gerard C. M. ;
van der Palen, Job ;
Doggen, Carine J. M. ;
Lowik, Marije M. .
LANCET, 2016, 388 (10060) :2607-2617
[33]   Clinical outcomes three-year after revascularization with biodegradable polymer stents: ultrathin-strut sirolimus-eluting stent versus biolimus-eluting stent: from the Scandinavian organization for randomized trials with clinical outcome VII trial [J].
Ellert, Julia ;
Maeng, Michael ;
Raungaard, Bent ;
Hansen, Knud Norregaard ;
Kahlert, Johnny ;
Jensen, Svend Eggert ;
Botker, Hans Erik ;
Hansen, Henrik Steen ;
Lassen, Jens Flensted ;
Christiansen, Evald Hoj ;
Jensen, Lisette Okkels .
CORONARY ARTERY DISEASE, 2020, 31 (06) :485-492
[34]   Stent Thrombosis with Biodegradable Polymer Drug-Eluting Stents versus Durable Polymer Sirolimus-Eluting Stents: An Update Meta-Analysis [J].
Zhu, Lin ;
Lv, Yi Ning ;
Wang, Li Yu .
CARDIOLOGY, 2015, 130 (02) :96-105
[35]   Subgroup Analysis Comparing Ultrathin, Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin, Durable Polymer Everolimus-Eluting Stents in Acute Coronary Syndrome Patients: BIOFLOW V Acute Coronary Syndromes Subgroup [J].
Roguin, Ariel ;
Kandzari, David E. ;
Marcusohn, Erez ;
Koolen, Jacques J. ;
Doros, Gheorghe ;
Massaro, Joseph M. ;
Garcia-Garcia, Hector M. ;
Bennett, Johan ;
Gharib, Elie G. ;
Cutlip, Donald E. ;
Waksman, Ron .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (10)
[36]   Angiographic and clinical outcomes of patients implanted with ultrathin, biodegradable polymer sirolimus-eluting stents versus durable polymer drug-eluting stents for percutaneous coronary intervention: an updated meta-analysis based on randomized controlled trials [J].
Liao, Chen ;
Liao, Sen ;
Liu, Miaoweng ;
Xu, Ruoxin ;
Peng, Jinhua ;
Wei, Yiping ;
Zhang, Wenxiong .
JOURNAL OF CARDIOVASCULAR SURGERY, 2021, 62 (02) :175-187
[37]   Clinical outcomes of zotarolimus-eluting stents versus the first generation sirolimus-eluting stents and paclitaxel-eluting stents: A meta-analysis of randomized trials [J].
Gao Wei ;
Yuan Fang ;
Ren Yaqi ;
Chen Lin ;
Wang Ningfu .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 157 (01) :152-156
[38]   First-in-man randomised comparison of the Angiolite durable fluoroacrylate polymer-based sirolimus-eluting stent versus a durable fluoropolymer-based everolimus-eluting stent in patiens with coronary artery disease: the ANGIOLITE trial [J].
Moreu, Jose ;
Moreno-Gomez, Raul ;
Perez de Prado, Armando ;
Garcia del Blanco, Bruno ;
Trillo, Ramiro ;
Pinar, Eduardo ;
Molina, Eduardo ;
Zueco, Javier ;
Merchan, Antonio ;
Francisco Diaz-Fernandez, Jose ;
Amat, Ignacio .
EUROINTERVENTION, 2019, 15 (12) :E1081-U104
[39]   Long-Term Clinical Outcomes of Everolimus-Eluting Stents versus Sirolimus-Eluting Stents: Systematic Review and a Meta-Analysis of 14 Randomized Control Trials, Focused on Stent Thrombosis [J].
Toyota, Toshiaki ;
Shiomi, Hiroki ;
Morimoto, Takeshi ;
Kimura, Takeshi .
CIRCULATION, 2014, 130
[40]   Comparison of the Ultrathin Strut, Biodegradable Polymer Sirolimus-eluting Stent With a Durable Polymer Everolimus-eluting Stent in a Chinese Population: The Randomized BIOFLOW VI Trial [J].
Li, Chongjian ;
Yang, Yuejin ;
Han, Yaling ;
Song, Dan ;
Xu, Jing ;
Guan, Changdong ;
Gao, Runlin ;
Garcia-Garcia, Hector M. ;
Waksman, Ron ;
Xu, Bo .
CLINICAL THERAPEUTICS, 2020, 42 (04) :649-+