Heat transfer and pressure drop characteristics of forced convective evaporation in horizontal tubes with coiled wire inserts

被引:44
作者
Akhavan-Behabadi, M. A. [1 ]
Mohseni, S. G. [1 ]
Najafi, H. [1 ]
Ramazanzadeh, H. [1 ]
机构
[1] Univ Tehran, Sch Mech Engn, Univ Coll Engn, Tehran, Iran
关键词
Heat transfer; Evaporation; Pressure drop; R-134a; Coiled wire; AUGMENTATION; CONDENSATION;
D O I
10.1016/j.icheatmasstransfer.2009.07.009
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat transfer enhancement and pressure drop increasing during evaporation of R-134a due to the presence of coiled wire insert inside a horizontal evaporator was studied experimentally. The test evaporator was an electrically heated copper tube of 1200 mm length and 7.5 mm inside diameter. Helically wire coils with different wire diameters of 0.5, 0.7, 1.0 and 1.5 mm and different coil pitches of 5, 8, 10 and 13 mm were made and used in full length of the test evaporator. For each inserted tube and also the plain tube, several test runs were carried out with different mass velocities and heat fluxes. From analysis of acquired data, it was found that the coiled wire inserts enhance the heat transfer coefficient but with a higher penalty due to the increasing of pressure drop, in comparison to that for the plain flow. An empirical correlation has been developed to predict the heat transfer coefficient during evaporation inside a horizontal tube in the presence of a coiled wire insert. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1089 / 1095
页数:7
相关论文
共 13 条
[1]   EXPERIMENTAL-STUDY OF HEAT-TRANSFER AUGMENTATION VERSUS PUMPING POWER IN A HORIZONTAL R12 EVAPORATOR [J].
AGRAWAL, KN ;
VARMA, HK .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1991, 14 (05) :273-281
[2]   Pressure drop increase of forced convective condensation inside horizontal coiled wire inserted tubes [J].
Akhavan-Behabadi, M. A. ;
Salimpour, M. R. ;
Pazouki, V. A. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2008, 35 (09) :1220-1226
[3]   Investigation on heat transfer and pressure drop during swirl flow boiling of R-134a in a horizontal tube [J].
Akhavan-Behabadi, M. A. ;
Kumar, Ravi ;
Jamali, M. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (7-8) :1918-1927
[4]   Augmentation of forced convection condensation heat transfer inside a horizontal tube using spiral spring inserts [J].
Akhavan-Behabadi, MA ;
Salimpoor, MR ;
Kumar, R ;
Agrawal, KN .
JOURNAL OF ENHANCED HEAT TRANSFER, 2005, 12 (04) :373-384
[5]  
*AM SOC HEAT REFR, 2005, AM SOC HEAT REFR AIR, P20
[6]  
GUNGOR KE, 1987, CHEM ENG RES DES, V65, P148
[7]   Two phase flow patterns and boiling heat transfer in tubes containing helical wire inserts .1. Flow patterns and boiling heat transfer coefficients [J].
Lan, J ;
Disimile, PJ ;
Weisman, J .
JOURNAL OF ENHANCED HEAT TRANSFER, 1997, 4 (04) :269-281
[8]   A COMPARISON OF AUGMENTATION TECHNIQUES DURING IN-TUBE EVAPORATION OF R-113 [J].
REID, RS ;
PATE, MB ;
BERGLES, AE .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1991, 113 (02) :451-458
[9]  
Schultz RR., 1979, AIChE Symposium Sr, V75, P32
[10]   Evaporation of R407C/oil mixtures inside corrugated and micro-fin tubes [J].
Targanski, Waldemar ;
Cieslinski, Janusz T. .