High resolution Varying Field Drift Tube Ion Mobility Spectrometer with diffusion autocorrection

被引:5
|
作者
Chen, Xi [1 ,2 ]
Gandhi, Viraj [1 ,2 ]
Coots, Joshua [1 ,2 ]
Fan, Yinghui [3 ]
Xu, Liang [4 ,5 ]
Fukushima, Nobuhiko [6 ]
Larriba-Andaluz, Carlos [1 ]
机构
[1] IUPUI, Dept Mech Engn, 723 W Michigan St, Indianapolis, IN 46202 USA
[2] Purdue Univ, W Lafayette, IN 47907 USA
[3] Shantou Univ, Coll Engn, Shantou 515063, Peoples R China
[4] Shanghai Jiao Tong Univ, Key Lab Laser Plasmas, Minist Educ, Shanghai 200240, Peoples R China
[5] Shanghai Jiao Tong Univ, Sch Phys & Astron, Shanghai 200240, Peoples R China
[6] Kanomax Japan Inc, Suita, Osaka 5650805, Japan
关键词
Drift tube; Ion mobility; Differential mobility analyzer; PM0.1; Mobility diameter; IMS-IMS; NM;
D O I
10.1016/j.jaerosci.2019.105485
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Drift tubes (DT) are prominent tools to classify small ions in the gas phase. This is in contrast with its limited use in the aerosol field at atmospheric pressures where the differential mobility analyzer (DMA) has been the tool of choice. While the DMA has been successful, it does not normally achieve the resolution of a common DT. On the other hand, the size range of the DT is limited as well as its sensitivity. Here we propose a variation of the DT where a varying linearly decreasing field is used instead of the constant field commonly used in DT. The Varying Field Drift Tube (VFDT) has the advantage that it allows for diffusion constriction in the axial direction and thus a larger package of ions can be allowed into the system increasing its sensitivity without hampering its resolution. The VFDT also generally outperforms the DT in resolution and this is demonstrated theoretically and empirically reaching resolutions of over 90 in our data although higher resolutions are expected. The diffusion constriction capabilities are also proven theoretically and experimentally by using a mixture of tetraalkylammonium salts while injecting broad packets of ions into the system. The transformation from the raw variable arrival time distribution to Collision Cross Section or mobility diameter is linear making the transformation as simple as with a DMA.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Effect of electric field of drift tube on performance of a vacuum, ultraviolet ionization-ion mobility spectrometer
    Shi Yingguo
    Shao Shiyong
    Li Anlin
    Yao Lian
    Wang Bin
    Li Fang
    Wang Junde
    Li Haiyang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (09) : 1353 - 1356
  • [12] Bradbury-Nielsen vs. Field switching shutters for high resolution drift tube ion mobility spectrometers
    Kirk, Ansgar T.
    Zimmermann, Stefan
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2014, 17 (3-4) : 131 - 137
  • [13] Flexible Drift Tube for High Resolution Ion Mobility Spectrometry (Flex-DT-IMS)
    Smith, Barry L.
    Boisdon, Cedric
    Young, Iain S.
    Praneenararat, Thanit
    Vilaivan, Tirayut
    Maher, Simon
    ANALYTICAL CHEMISTRY, 2020, 92 (13) : 9104 - 9112
  • [14] A gated atmospheric pressure drift tube ion mobility spectrometer-time-of-flight mass spectrometer
    Heptner, Andre
    Reinecke, Tobias
    Langejuergen, Jens
    Zimmermann, Stefan
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1356 : 241 - 248
  • [15] Miniaturized Drift Tube Ion Mobility Spectrometer with Ultra-Fast Polarity Switching
    Hitzemann, Moritz
    Kirk, Ansgar T.
    Lippmann, Martin
    Bohnhorst, Alexander
    Zimmermann, Stefan
    ANALYTICAL CHEMISTRY, 2022, 94 (02) : 777 - 786
  • [16] Augmenting Ion Trap Mass Spectrometers Using a Frequency Modulated Drift Tube Ion Mobility Spectrometer
    Morrison, Kelsey A.
    Siems, William F.
    Clowers, Brian H.
    ANALYTICAL CHEMISTRY, 2016, 88 (06) : 3121 - 3129
  • [17] High sensitivity field asymmetric ion mobility spectrometer
    Chavarria, Mario A.
    Matheoud, Alessandro V.
    Marmillod, Philippe
    Liu, Youjiang
    Kong, Deyi
    Brugger, Jurgen
    Boero, Giovanni
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (03):
  • [18] Necessary conditions for peak resolution in an ion mobility increment spectrometer with a flat drift chamber
    S. V. Shibkov
    A. A. Elistratov
    L. A. Shcherbakov
    Technical Physics Letters, 2008, 34 : 714 - 717
  • [19] Necessary conditions for peak resolution in an ion mobility increment spectrometer with a flat drift chamber
    Shibkov, S. V.
    Elistratov, A. A.
    Shcherbakov, L. A.
    TECHNICAL PHYSICS LETTERS, 2008, 34 (08) : 714 - 717
  • [20] A compact high resolution electrospray ionization ion mobility spectrometer
    Reinecke, T.
    Kirk, A. T.
    Ahrens, A.
    Raddatz, C. -R.
    Thoben, C.
    Zimmermann, S.
    TALANTA, 2016, 150 : 1 - 6