High resolution Varying Field Drift Tube Ion Mobility Spectrometer with diffusion autocorrection

被引:5
|
作者
Chen, Xi [1 ,2 ]
Gandhi, Viraj [1 ,2 ]
Coots, Joshua [1 ,2 ]
Fan, Yinghui [3 ]
Xu, Liang [4 ,5 ]
Fukushima, Nobuhiko [6 ]
Larriba-Andaluz, Carlos [1 ]
机构
[1] IUPUI, Dept Mech Engn, 723 W Michigan St, Indianapolis, IN 46202 USA
[2] Purdue Univ, W Lafayette, IN 47907 USA
[3] Shantou Univ, Coll Engn, Shantou 515063, Peoples R China
[4] Shanghai Jiao Tong Univ, Key Lab Laser Plasmas, Minist Educ, Shanghai 200240, Peoples R China
[5] Shanghai Jiao Tong Univ, Sch Phys & Astron, Shanghai 200240, Peoples R China
[6] Kanomax Japan Inc, Suita, Osaka 5650805, Japan
关键词
Drift tube; Ion mobility; Differential mobility analyzer; PM0.1; Mobility diameter; IMS-IMS; NM;
D O I
10.1016/j.jaerosci.2019.105485
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Drift tubes (DT) are prominent tools to classify small ions in the gas phase. This is in contrast with its limited use in the aerosol field at atmospheric pressures where the differential mobility analyzer (DMA) has been the tool of choice. While the DMA has been successful, it does not normally achieve the resolution of a common DT. On the other hand, the size range of the DT is limited as well as its sensitivity. Here we propose a variation of the DT where a varying linearly decreasing field is used instead of the constant field commonly used in DT. The Varying Field Drift Tube (VFDT) has the advantage that it allows for diffusion constriction in the axial direction and thus a larger package of ions can be allowed into the system increasing its sensitivity without hampering its resolution. The VFDT also generally outperforms the DT in resolution and this is demonstrated theoretically and empirically reaching resolutions of over 90 in our data although higher resolutions are expected. The diffusion constriction capabilities are also proven theoretically and experimentally by using a mixture of tetraalkylammonium salts while injecting broad packets of ions into the system. The transformation from the raw variable arrival time distribution to Collision Cross Section or mobility diameter is linear making the transformation as simple as with a DMA.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Characterization of a high resolution drift tube ion mobility spectrometer with a multi-ion source platform
    Adamov, Alexey
    Mauriala, Timo
    Teplov, Victor
    Laakia, Jaakko
    Pedersen, Christian Schack
    Kotiaho, Tapio
    Sysoev, Alexey A.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 298 (1-3) : 24 - 29
  • [2] Miniaturized high-performance drift tube ion mobility spectrometer
    Ahrens, Andre
    Hitzemann, Moritz
    Zimmermann, Stefan
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2019, 22 (02) : 77 - 83
  • [3] High-Resolution Drift Tube Ion Mobility Spectrometer with Ultra-Fast Polarity Switching
    Hitzemann, Moritz
    Kirk, Ansgar T.
    Lippmann, Martin
    Nitschke, Alexander
    Burckhardt, Olaf
    Winkelholz, Jonas
    Zimmermann, Stefan
    ANALYTICAL CHEMISTRY, 2024, 96 (36) : 14630 - 14638
  • [4] Optimization design of drift tube for ion mobility spectrometer based on simulation of drift electric field
    Liu, Xin
    Li, Shengli
    Li, Mingshu
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2012, 15 (04) : 231 - 237
  • [5] High resolving power electrospray drift tube ion mobility spectrometer with heated desolvation tube
    Boillat, Marc-Aurele
    Hauser, Peter C.
    ANALYTICA CHIMICA ACTA, 2025, 1338
  • [7] Coupling of a High-Resolution Ambient Pressure Drift Tube Ion Mobility Spectrometer to a Commercial Time-of-flight Mass Spectrometer
    Allers, Maria
    Timoumi, Laila
    Kirk, Ansgar T.
    Schlottmann, Florian
    Zimmermann, Stefan
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2018, 29 (11) : 2208 - 2217
  • [8] Electric Field Optimization in Multi-physics Model of Drift Tube Ion Mobility Spectrometer
    Fang, Ziyi
    He, Mang
    2022 IEEE 10TH ASIA-PACIFIC CONFERENCE ON ANTENNAS AND PROPAGATION, APCAP, 2022,
  • [9] Evolution of tropospheric ions observed by an ion mobility spectrometer with a drift tube
    Nagato, K
    Ogawa, T
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1998, 103 (D12) : 13917 - 13925
  • [10] Separation of biologically relevant isomers on an Orbitrap mass spectrometer using high-resolution drift tube ion mobility and varied drift gas mixtures
    Kaszycki, Julia L.
    La Rotta, Aurelio
    Colsch, Benoit
    Fenaille, Francois
    Dauly, Claire
    Kamleh, Anas
    Wu, Ching
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2019, 33 : 3 - 10