Towards nanometric resolution in multilayer depth profiling: a comparative study of RBS, SIMS, XPS and GDOES

被引:82
作者
Escobar Galindo, Ramon [1 ,2 ]
Gago, Raul [1 ]
Duday, David [3 ]
Palacio, Carlos [4 ]
机构
[1] CSIC, Inst Ciencia Mat Madrid, Madrid 28049, Spain
[2] Univ Autonoma Madrid, Ctr Microanal Mat, E-28049 Madrid, Spain
[3] Ctr Rech Publ Gabriel Lippmann, Dept Sci & Anal Mat, L-4422 Belvaux, Luxembourg
[4] Univ Autonoma Madrid, Dept Fis Aplicada, E-28049 Madrid, Spain
关键词
Depth profiling; XPS; SIMS; GDOES; RBS; Multilayer; High resolution; OPTICAL-EMISSION-SPECTROSCOPY; GLOW-DISCHARGE SPECTROMETRY; ANGLE-RESOLVED XPS; THIN-FILMS; METAL COATINGS; MAGNETIC SPECTROGRAPH; SURFACE-ANALYSIS; CRATER SHAPE; PRIMARY ION; ATOM-PROBE;
D O I
10.1007/s00216-009-3339-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An increasing amount of effort is currently being directed towards the development of new functionalized nanostructured materials (i.e., multilayers and nanocomposites). Using an appropriate combination of composition and microstructure, it is possible to optimize and tailor the final properties of the material to its final application. The analytical characterization of these new complex nanostructures requires high-resolution analytical techniques that are able to provide information about surface and depth composition at the nanometric level. In this work, we comparatively review the state of the art in four different depth-profiling characterization techniques: Rutherford backscattering spectroscopy (RBS), secondary ion mass spectrometry (SIMS), X-ray photoelectron spectroscopy (XPS) and glow discharge optical emission spectroscopy (GDOES). In addition, we predict future trends in these techniques regarding improvements in their depth resolutions. Subnanometric resolution can now be achieved in RBS using magnetic spectrometry systems. In SIMS, the use of rotating sample holders and oxygen flooding during analysis as well as the optimization of floating low-energy ion guns to lower the impact energy of the primary ions improves the depth resolution of the technique. Angle-resolved XPS provides a very powerful and nondestructive technique for obtaining depth profiling and chemical information within the range of a few monolayers. Finally, the application of mathematical tools (deconvolution algorithms and a depth-profiling model), pulsed sources and surface plasma cleaning procedures is expected to greatly improve GDOES depth resolution.
引用
收藏
页码:2725 / 2740
页数:16
相关论文
共 98 条
[1]   XPS AND SIMS/SNMS MEASUREMENTS ON THIN METAL-OXIDE LAYERS [J].
ALBERS, T ;
NEUMANN, M ;
LIPINSKY, D ;
BENNINGHOVEN, A .
APPLIED SURFACE SCIENCE, 1993, 70-1 (1 -4 pt A) :49-52
[2]  
Alford T.L., 2007, Fundamentals of Nanoscale Film Analysis
[3]   A wide-angle magnetic spectrograph of a novel design [J].
Andrzejewski, Roch ;
Lucas, Julio ;
Guirao, Angel ;
Gordillo, Nuria ;
Boerma, Dirk .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 249 :939-942
[4]   Glow discharge optical emission spectrometry: moving towards reliable thin film analysis - a short review [J].
Angeli, J ;
Bengtson, A ;
Bogaerts, A ;
Hoffmann, V ;
Hodoroaba, VD ;
Steers, E .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (06) :670-679
[5]   Growth and characterization of Cr2N/CrN multilayer coatings [J].
Aouadi, SM ;
Schultze, DM ;
Rohde, SL ;
Wong, KC ;
Mitchell, KAR .
SURFACE & COATINGS TECHNOLOGY, 2001, 140 (03) :269-277
[6]   A high resolution magnetic spectrograph for ion beam analysis [J].
Arnoldbik, WM ;
Wolfswinkel, W ;
Inia, DK ;
Verleun, VCG ;
Lobner, S ;
Reinders, JA ;
Labohm, F ;
Boerma, DO .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 118 (1-4) :566-572
[7]   High-temperature oxidation of CrN/AlN multilayer coatings [J].
Bardi, U ;
Chenakin, SP ;
Ghezzi, F ;
Giolli, C ;
Goruppa, A ;
Lavacchi, A ;
Miorin, E ;
Pagura, C ;
Tolstogouzov, A .
APPLIED SURFACE SCIENCE, 2005, 252 (05) :1339-1349
[8]   Multilayer reference coatings for depth profile standards [J].
Beck, U ;
Reiners, G ;
Wirth, T ;
Hoffmann, V ;
Prassler, F .
THIN SOLID FILMS, 1996, 290 :57-62
[9]   Pulsed glow discharges for analytical applications [J].
Belenguer, Ph. ;
Ganciu, M. ;
Guillot, Ph. ;
Nelis, Th. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (07) :623-641
[10]  
Benninghoven A., 1987, SECONDARY ION MASS S, P1227