Determination of Mohr-Coulomb failure envelope, mechanical properties and UPV of commercial cement-lime mortar

被引:8
作者
Ghimire, Amrit [1 ]
Noor-E-Khuda, Sarkar [2 ]
Ullah, Shah Neyamat [3 ]
Suntharavadivel, Thuraichamy [4 ]
机构
[1] Deakin Univ, Sch Engn & Built Environm, Waurn Ponds, Vic 3216, Australia
[2] Cent Queensland Univ, Sch Engn & Technol, Melbourne, Vic 3000, Australia
[3] Cent Queensland Univ, Sch Engn & Technol, Gladstone, Qld 4680, Australia
[4] Cent Queensland Univ, Sch Engn & Technol, Rockhampton, Qld 4701, Australia
关键词
Mortar; Triaxial loading; Uniaxial loading; Mohr-Coulomb criteria; UPV; Stress-strain; WEATHERED GRANITES; TRIAXIAL BEHAVIOR; FLEXURAL STRENGTH; CONCRETE; MASONRY; PRESSURE; TESTS; RATIO; WATER;
D O I
10.1617/s11527-022-01959-z
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Mortar in masonry structures can be subjected to both uniaxial and triaxial loading. Determining the mechanical properties and/or failure criteria of the commonly used mortar is necessary for the structural performance assessment of new and existing masonry buildings using non-destructive testing and/or finite element modelling methods. In this paper, the stress-strain behaviour of a commercially available cement-lime mortar is investigated under uniaxial and triaxial loading. The axial compressive strength, modulus of elasticity, Mohr-Coulomb failure envelopes of the mortar are determined over a range of conditions. Mortar specimens were prepared with a water to cementitious material ratio (w/cm) of 0.6-0.7 and were tested at curing ages of 3, 7, 14, and 28 days, under confining pressures of 0, 100, 250, 500 and 750 kPa. Ultrasonic pulse velocity (UPV) of the specimens were measured before the destructive testing. The results indicate that the influence of curing age and confining pressure on the axial compressive strength of the mortar can be predicted using proposed linear correlations between (i) The confining pressure and the axial compressive strength and (ii) The UPV and the axial compressive strength. From the test results, the strength parameters of the Mohr-Coulomb failure criterion were also determined. It is observed that cohesion is more sensitive to changes in curing age and w/cm than the friction angle, which varied between 32 and 33 degrees.
引用
收藏
页数:19
相关论文
共 44 条
  • [1] [Anonymous], 2016, 2350 AS
  • [2] [Anonymous], 2018, 3700 AS
  • [3] Characterisation of polymer cement mortar composites containing carbon fibre or auxetic fabric overlays and inserts under flexure
    Asad, Mohammad
    Dhanasekar, Manicka
    Zahra, Tatheer
    Thambiratnam, David
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2019, 224 : 863 - 879
  • [4] Assaad JJ, 2009, ACI MATER J, V106, P439
  • [5] Atkinson RH, 1985, P 3 N AM MAS C ARL
  • [6] Australian Standard, 2014, 1012812014 AS
  • [7] Australian Standard,, 2014, 101222014 AS
  • [8] Benedetti A., 2008, P 8 INT SEM STRUCT M
  • [9] Binda L, 1998, MATER STRUCT, V31, P2
  • [10] High-dynamic compressive and tensile strength of specimens made of cementitious materials
    Binder, E.
    Reihsner, R.
    Yuan, Y.
    Mang, H. A.
    Pichler, B. L. A.
    [J]. CEMENT AND CONCRETE RESEARCH, 2020, 129