Noninvasive corollary vessel wall and plaque imaging with magnetic resonance imaging

被引:0
作者
Botnar, RM
Stuber, M
Kissinger, KV
Kim, WY
Spuentrup, E
Manning, WJ
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Cardiac MR Ctr, Boston, MA 02215 USA
[2] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[3] Harvard Univ, Sch Med, Boston, MA USA
[4] Philips Med Syst, Best, Netherlands
关键词
vessels; plaque; magnetic resonance imaging; atherosclerosis;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Conventional x-ray angiography frequently underestimates the true burden of atherosclerosis. Although intravascular ultrasound allows for imaging of coronary plaque, this invasive technique is inappropriate for screening or serial examinations. We therefore sought to develop a noninvasive free-breathing MR technique For coronary vessel wall imaging. We hypothesized that such an approach would allow for in vivo imaging of coronary atherosclerosis. Methods and Results-Ten subjects, including 5 healthy adult volunteers (aged 35+/-17 years, range 19 to 56 years) and 5 patients (aged 60+/-4 years, range 56 to 66 years) with x-ray-confirmed coronary artery disease (CAD), were studied with a T2-weighted, dual-inversion, fast spin-echo MR sequence. Multiple adjacent 5-mm cross-sectional images of the proximal right coronary artery were obtained with an in-plane resolution of 0.5x1.0 mm. A right hemidiaphragmatic navigator was used to facilitate free-breathing MR acquisition. Coronary vessel wall images were readily acquired in all subjects. Both coronary vessel wall thickness (1.5+/-0.2 versus 1.0+/-0.2 mm) and wall area (21.2+/-3.1 versus 13.7+/-4.2 mm(2)) were greater in patients with CAD (both P<0.02 versus healthy adults). Conclusions-In vivo free-breathing coronary vessel wall and plaque imaging with MR has been successfully implemented in humans. Coronary wall thickness and wall area were significantly greater in patients with angiographic CAD. The presented technique may have potential applications in patients with known or suspected atherosclerotic CAD or for serial evaluation after pharmacological intervention.
引用
收藏
页码:2582 / 2587
页数:6
相关论文
共 29 条
  • [1] One-year follow-up after intravascular ultrasound assessment of moderate left main coronary artery disease in patients with ambiguous angiograms
    Abizaid, AS
    Mintz, GS
    Abizaid, A
    Mehran, R
    Lansky, AJ
    Pichard, AD
    Satler, LF
    Wu, HS
    Kent, KM
    Leon, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (03) : 707 - 715
  • [2] Long-term follow-up after percutaneous transluminal coronary angioplasty was not performed based on intravascular ultrasound findings - Importance of lumen dimensions
    Abizaid, AS
    Mintz, GS
    Mehran, R
    Abizaid, A
    Lansky, AJ
    Pichard, AD
    Satler, LF
    Wu, HS
    Pappas, C
    Kent, KM
    Leon, MB
    [J]. CIRCULATION, 1999, 100 (03) : 256 - 261
  • [3] Intracranial black-blood MR angiography with high-resolution 3D fast spin echo
    Alexander, AL
    Buswell, HR
    Sun, Y
    Chapman, BE
    Tsuruda, TS
    Parker, DL
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (02) : 298 - 310
  • [4] Botnar RM, 1999, JMRI-J MAGN RESON IM, V10, P821, DOI 10.1002/(SICI)1522-2586(199911)10:5<821::AID-JMRI29>3.0.CO
  • [5] 2-7
  • [6] Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA
    Botnar, RM
    Stuber, M
    Danias, PG
    Kissinger, KV
    Manning, WJ
    [J]. CIRCULATION, 1999, 99 (24) : 3139 - 3148
  • [7] Prospective navigator correction of image position for coronary MR angiography
    Danias, PG
    McConnell, MV
    Khasgiwala, VC
    Chuang, ML
    Edelman, RR
    Manning, WJ
    [J]. RADIOLOGY, 1997, 203 (03) : 733 - 736
  • [8] CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY
    EDELMAN, RR
    MANNING, WJ
    BURSTEIN, D
    PAULIN, S
    [J]. RADIOLOGY, 1991, 181 (03) : 641 - 643
  • [9] FAST SELECTIVE BLACK BLOOD MR IMAGING
    EDELMAN, RR
    CHIEN, D
    KIM, D
    [J]. RADIOLOGY, 1991, 181 (03) : 655 - 660
  • [10] ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES
    EHMAN, RL
    FELMLEE, JP
    [J]. RADIOLOGY, 1989, 173 (01) : 255 - 263