Simultaneous quantification of caffeine and chlorogenic acid in coffee green beans and varietal classification of the samples by HPLC-DAD coupled with chemometrics

被引:41
作者
De Luca, Silvia [1 ]
Ciotoli, Eleonora [1 ]
Biancolillo, Alessandra [1 ]
Bucci, Remo [1 ]
Magri, Andrea D. [1 ]
Marini, Federico [1 ,2 ]
机构
[1] Univ Roma La Sapienza, Dept Chem, Ple Aldo Moro 5, I-00185 Rome, Italy
[2] Dept Food Sci, Private Bag X1, ZA-7602 Stellenbosch, South Africa
关键词
Green coffee; Caffeine; Chlorogenic acid (5-caffeoylquinic acid); HPLC-DAD; Multivariate curve resolution (MCR); Classification; Partial least squares discriminant analysis (PLS-DA); Soft independent modeling of class analogies (SIMCA); MULTIVARIATE CURVE RESOLUTION; OVERLAPPING CHROMATOGRAPHIC PEAKS; EVOLVING FACTOR-ANALYSIS; PARTIAL LEAST-SQUARES; CARDIOVASCULAR-DISEASE; NICOTINIC-ACID; EXTRACTION; HEALTH; RISK; TRIGONELLINE;
D O I
10.1007/s11356-018-1379-6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A chromatographic procedure (HPLC-DAD) using a relatively rapid gradient has been combined with a chemometric curve deconvolution method, multivariate curve resolution-alternating least squares (MCR-ALS), in order to quantify caffeine and chlorogenic acid in green coffee beans. Despite that the HPLC analysis (at these specific operating conditions) presents some coeluting peaks, MCR-ALS allowed their resolution and, consequently, the creation of a calibration curve to be used for the quantification of the analytes of interest; this procedure led to a high accuracy in the quantification of caffeine and chlorogenic acid present in the samples. In a second part of this study, the possibility of classifying the green coffee beans on the basis of their cultivar (Arabica or Robusta), by partial least squares discriminant analysis (PLS-DA) and soft independent modeling of class analogies (SIMCA), has been explored. SIMCA resulted in 100% of sensitivity and specificity for the Arabica class, while for the Robusta, it reached 66.7% of sensitivity and 100% of specificity, or 100% of sensitivity and 100% of specificity, depending on the extraction procedure followed prior to the chromatographic analysis; PLS-DA achieved 100% of correct classification independently of the procedure used for the extraction.
引用
收藏
页码:28748 / 28759
页数:12
相关论文
共 55 条
  • [1] [Anonymous], 2002, Principal components analysis
  • [2] [Anonymous], 2003, User's Guide to Principal Components
  • [3] Partial least squares for discrimination
    Barker, M
    Rayens, W
    [J]. JOURNAL OF CHEMOMETRICS, 2003, 17 (03) : 166 - 173
  • [4] Measurement of caffeine in coffee beans with UV/vis spectrometer
    Belay, Abebe
    Ture, Kassahun
    Redi, Mesfin
    Asfaw, Araya
    [J]. FOOD CHEMISTRY, 2008, 108 (01) : 310 - 315
  • [5] Partial least squares discriminant analysis: taking the magic away
    Brereton, Richard G.
    Lloyd, Gavin R.
    [J]. JOURNAL OF CHEMOMETRICS, 2014, 28 (04) : 213 - 225
  • [6] Development of an HPLC/diode-array detector method for simultaneous determination of trigonelline, nicotinic acid, and caffeine in coffee
    Casal, S
    Oliveira, MV
    Ferreira, MA
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (20) : 3187 - 3195
  • [7] HPLC/diode-array applied to the thermal degradation of trigonelline, nicotinic acid and caffeine in coffee
    Casal, S
    Oliveira, MB
    Ferreira, MA
    [J]. FOOD CHEMISTRY, 2000, 68 (04) : 481 - 485
  • [8] CHOU TM, 1994, COMP BIOCHEM PHYS C, V109, P173, DOI 10.1016/0742-8413(94)00048-F
  • [9] USE OF A MICROCOMPUTER FOR THE DEFINITION OF MULTIVARIATE CONFIDENCE-REGIONS IN MEDICAL DIAGNOSIS BASED ON CLINICAL LABORATORY PROFILES
    COOMANS, D
    BROECKAERT, I
    DERDE, MP
    TASSIN, A
    MASSART, DL
    WOLD, S
    [J]. COMPUTERS AND BIOMEDICAL RESEARCH, 1984, 17 (01): : 1 - 14
  • [10] Robust SIMCA-bounding influence of outliers
    Department of Chemometrics, The University of Silesia, 9 Szkolna Street, 40-006 Katowice, Poland
    不详