Single-pulse low-energy-driven transient inversion X-ray lasers

被引:5
作者
Janulewicz, KA [1 ]
Priebe, G [1 ]
Tümmler, J [1 ]
Nickles, PV [1 ]
机构
[1] Max Born Inst, D-12489 Berlin, Germany
关键词
collisional pumping; pulse shaping; transient inversion; X-ray laser; X-ray laser driver;
D O I
10.1109/JSTQE.2004.837712
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper deals with some aspects of a new pump method applied to collisional transient X-ray lasers working with ions of the Ni-like isoelectronic sequence. Specifically, Ni-like silver is the element of main interest. It is shown that a single profiled picosecond pulse with energy of about 1J is able to excite efficiently the active medium. A small amount of the produced plasma facilitates its heating and following excitation. Application of other available pump laser systems and the resulting medium kinetics are analyzed. Pump pulse profiling and control over the pulse shape in a laser driver are highlighted on the background of the recent development in laser driver technology. Prospects and possible development trends are discussed as well.
引用
收藏
页码:1368 / 1372
页数:5
相关论文
共 17 条
[1]   Gain saturation regime for laser-driven tabletop, transient Ni-like ion x-ray lasers [J].
Dunn, J ;
Li, Y ;
Osterheld, AL ;
Nilsen, J ;
Hunter, JR ;
Shlyaptsev, VN .
PHYSICAL REVIEW LETTERS, 2000, 84 (21) :4834-4837
[2]   Demonstration of transient gain x-ray lasers near 20 nm for nickellike yttrium, zirconium, niobium, and molybdenum [J].
Dunn, J ;
Nilsen, J ;
Osterheld, AL ;
Li, YL ;
Shlyaptsev, VN .
OPTICS LETTERS, 1999, 24 (02) :101-103
[3]   Demonstration of x-ray amplification in transient gain nickel-like palladium scheme [J].
Dunn, J ;
Osterheld, AL ;
Shepherd, R ;
White, WE ;
Shlyaptsev, VN ;
Stewart, RE .
PHYSICAL REVIEW LETTERS, 1998, 80 (13) :2825-2828
[4]  
DUNN J, 2000, J PHYS FRANCE, V4, pPR2
[5]   A COMPUTATIONAL INVESTIGATION OF THE NEON-LIKE GERMANIUM COLLISIONALLY PUMPED LASER [J].
HOLDEN, PB ;
HEALY, SB ;
LIGHTBODY, MTM ;
PERT, GJ ;
PLOWES, JA ;
KINGSTON, AE ;
ROBERTSON, E ;
LEWIS, CLS ;
NEELY, D .
JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 1994, 27 (02) :341-367
[6]   Output characteristics of a transient Ni-like Ag soft X-ray laser pumped by a single picosecond laser pulse [J].
Janulewicz, KA ;
Priebe, G ;
Lucianetti, A ;
Kroemer, R ;
Sandner, W ;
King, RE ;
Pert, GJ ;
Nickles, PV .
SOFT X-RAY LASERS AND APPLICATIONS V, 2003, 5197 :90-98
[7]   Review of state-of-the-art and output characteristics of table-top soft x-ray lasers [J].
Janulewicz, KA ;
Lucianetti, A ;
Priebe, G ;
Nickles, PV .
X-RAY SPECTROMETRY, 2004, 33 (04) :262-266
[8]   Saturated Ni-like Ag x-ray laser at 13.9 nm pumped by a single picosecond laser pulse [J].
Janulewicz, KA ;
Lucianetti, A ;
Priebe, G ;
Sandner, W ;
Nickles, PV .
PHYSICAL REVIEW A, 2003, 68 (05) :4
[9]  
Janulewicz KA, 2002, AIP CONF PROC, V641, P26, DOI 10.1063/1.1520994
[10]   Two-color transient pumping in Ni-like silver at 13.9 and 16.1 nm [J].
Kuba, J ;
Klisnick, A ;
Ros, D ;
Fourcade, P ;
Jamelot, G ;
Miquel, JL ;
Blanchot, N ;
Wyart, JF .
PHYSICAL REVIEW A, 2000, 62 (04) :7