Bioengineering bacteriophages to enhance the sensitivity of phage amplification-based paper fluidic detection of bacteria

被引:42
作者
Alcaine, S. D. [1 ]
Law, K. [2 ]
Ho, S. [2 ]
Kinchla, A. J. [1 ]
Sela, D. A. [1 ,2 ]
Nugen, S. R. [1 ,2 ]
机构
[1] Univ Massachusetts, Dept Food Sci, 246 Chenowethoratory,102 Holdsworth Way, Amherst, MA 01003 USA
[2] Univ Massachusetts, Dept Microbiol, Amherst, MA 01003 USA
基金
美国国家科学基金会; 美国食品与农业研究所;
关键词
Bacteriophage; Lateral flow assay; E; coli; Synthetic biology; Genetic engineering; Biosensor; water quality; LATERAL FLOW ASSAY; ESCHERICHIA-COLI; ELECTROWETTING VALVES; PATHOGEN DETECTION; PROBE; WATER; PCR; T7;
D O I
10.1016/j.bios.2016.03.047
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Bacteriophage (phage) amplification is an attractive method for the detection of bacteria due to a narrow phage-host specificity, short amplification times, and the phages' ability to differentiate between viable and non-viable bacterial cells. The next step in phage-based bacteria detection is leveraging bioengineered phages to create low-cost, rapid, and easy-to-use detection platforms such as lateral flow assays. Our work establishes the proof-of-concept for the use of bioengineered T7 phage strains to increase the sensitivity of phage amplification-based lateral flow assays. We have demonstrated a greater than 10-fold increase in sensitivity using a phage-based protein reporter, maltose-binding protein, over the detection of replicated T7 phage viron itself, and a greater then 100-fold increase in sensitivity using a phage-based enzymatic reporter, alkaline phosphatase. This increase in sensitivity enabled us to detect 10(3) CFU/mL of Escherichia coil in broth after 7 h, and by adding a filter concentration step, the ability to detect a regulatory relevant E. coli concentration of 100 CFU/100 mL in inoculated river water after 9 h, where the current standard requires days for results. The combination of the paper fluidic format with phage-based detection provides a platform for the development of novel diagnostics that are sensitive, rapid, and easy to use. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:14 / 19
页数:6
相关论文
共 30 条
[11]   Automating fluid delivery in a capillary microfluidic device using low-voltage electrowetting valves [J].
He, Fei ;
Nugen, Sam R. .
MICROFLUIDICS AND NANOFLUIDICS, 2014, 16 (05) :879-886
[12]   A novel colorimetric method for the detection of Escherichia coli using cytochrome c peroxidase-encoding bacteriophage [J].
Hoang, Hoang A. ;
Abe, Michiharu ;
Nakasaki, Kiyohiko .
FEMS MICROBIOLOGY LETTERS, 2014, 352 (01) :97-103
[13]   Development of a rapid immunochromatographic strip for detection of Escherichia coli O157 [J].
Jung, BY ;
Jung, SC ;
Kweon, CH .
JOURNAL OF FOOD PROTECTION, 2005, 68 (10) :2140-2143
[14]   Escherichia coli maltose-binding protein is uncommonly effective at promoting the solubility of polypeptides to which it is fused [J].
Kapust, RB ;
Waugh, DS .
PROTEIN SCIENCE, 1999, 8 (08) :1668-1674
[15]   An inkjet-printed electrowetting valve for paper-fluidic sensors [J].
Koo, Charmaine K. W. ;
He, Fei ;
Nugen, Sam R. .
ANALYST, 2013, 138 (17) :4998-5004
[16]  
Kutter E., 2005, BACTERIOPHAGES BIOL
[17]  
McComb R.B., 2013, Alkaline phosphatase
[18]   Stability of Staphylococcus aureus Phage ISP after Freeze-Drying (Lyophilization) [J].
Merabishvili, Maia ;
Vervaet, Chris ;
Pirnay, Jean-Paul ;
De Vos, Daniel ;
Verbeken, Gilbert ;
Mast, Jan ;
Chanishvili, Nino ;
Vaneechoutte, Mario .
PLOS ONE, 2013, 8 (07)
[19]   A comparison of ten USEPA approved total coliform/E-coli tests [J].
Olstadt, Jeremy ;
Schauer, James Jay ;
Standridge, Jon ;
Kluender, Sharon .
JOURNAL OF WATER AND HEALTH, 2007, 5 (02) :267-282
[20]   Lateral flow (immuno) assay: its strengths, weaknesses, opportunities and threats. A literature survey [J].
Posthuma-Trumpie, Geertruida A. ;
Korf, Jakob ;
van Amerongen, Aart .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (02) :569-582