Mobile-bearing total knee arthroplasty (TKA) expects high conformity and low contact stress. It is designed to correct the rotational mismatch between femoral and tibial components. We examined the difference in weight-bearing knee kinematics in patients with mobile-bearing and fixed-bearing TKA performing step-up activities. We randomly assigned 40 knees (37 patients) to mobile-bearing TKA (n = 20) or fixed-bearing TKA (n = 20). Using fluoroscopic imaging we evaluated knee kinematics during step-up activity one year after surgery. The total extent of rotation was not different for the two TKAs. Due to the axial rotation of the polyethylene insert, patients with mobile-bearing TKA had a wider range of absolute axial rotation. The position of the medial and the lateral condyles was significantly more posterior in the fixed-bearing TKA. There were only minor kinematic differences between the two TKAs. The polyethylene insert in the mobile-bearing TKA moved as designed especially with respect to the self-alignment feature. (C) 2014 Published by Elsevier Inc.
引用
收藏
页码:2393 / 2396
页数:4
相关论文
共 24 条
[1]   Variability of extraarticular tibial rotation references for total knee arthroplasty [J].
Akagi, M ;
Mori, S ;
Nishimura, S ;
Nishimura, A ;
Asano, T ;
Hamanishi, C .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (436) :172-176
[2]   2003 Hap Paul Award paper of the international society for technology in arthroplasty [J].
Banks, SA ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 2004, 19 (07) :809-816
[3]   Implant design affects knee arthroplasty kinematics during stair-stepping [J].
Banks, SA ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) :187-193
[4]   Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[5]  
BARTEL DL, 1995, CLIN ORTHOP RELAT R, P76
[6]   In Vivo Kinematics and Kinetics of a Bi-Cruciate Substituting Total Knee Arthroplasty: A Combined Fluoroscopic and Gait Analysis Study [J].
Catani, Fabio ;
Ensini, Andrea ;
Belvedere, Claudio ;
Feliciangeli, Alessandro ;
Benedetti, Maria Grazia ;
Leardini, Alberto ;
Giannini, Sandro .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2009, 27 (12) :1569-1575
[7]   The influence of surgical malalignment on the contact pressures of fixed and mobile bearing knee prostheses - a biomechanical study [J].
Cheng, CK ;
Huang, CH ;
Liau, JJ ;
Huang, CH .
CLINICAL BIOMECHANICS, 2003, 18 (03) :231-236
[8]  
D'Lima DD, 2000, CLIN ORTHOP RELAT R, P151
[9]   Mobile-bearing total knee arthroplasty - Design factors in minimizing wear [J].
Dennis, Douglas A. ;
Komistek, Richard A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) :70-77
[10]   Analysis of Wear in Retrieved Mobile and Fixed Bearing Knee Inserts [J].
Engh, Gerard A. ;
Zimmerman, Rebecca L. ;
Parks, Nancy L. ;
Engh, C. Anderson .
JOURNAL OF ARTHROPLASTY, 2009, 24 (06) :28-32