Optical and thermal integration analysis of supercritical CO2 Brayton cycles with a particle-based solar thermal plant based on annual performance

被引:13
作者
Chen, Rui [1 ,2 ]
Romero, Manuel [2 ]
Gonzalez-Aguilar, Jose [2 ]
Rovense, Francesco [2 ,3 ]
Rao, Zhenghua [1 ]
Liao, Shengming [1 ]
机构
[1] Cent South Univ, Sch Energy Sci & Engn, Changsha 410083, Peoples R China
[2] IMDEA Energy, High Temp Proc Unit, Avda Ramon de la Sagra 3, Mostoles 28935, Spain
[3] Rey Juan Carlos Univ, Dept Chem Energy & Mech Technol, Calle Tulipan S-N, Mostoles 28933, Spain
关键词
Supercritical CO2 brayton cycle; Solar concentration; Dense particle suspension; Central receiver system; Annual performance analysis; HELIOSTAT FIELD; HIGH-EFFICIENCY; RECEIVER; DESIGN; OPTIMIZATION; GENERATION; STORAGE; SYSTEM; LAYOUT;
D O I
10.1016/j.renene.2022.02.059
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Central receiver concentrating solar power (CSP) plants based on particles as heat transfer fluid in solar circuits and supercritical CO2 (S-CO2) Brayton cycles can fulfil the requirements for next generation CSP to improve solar-to-electric efficiency and reduce energy storage costs. However, effective incorporation of these two concepts requires an in-depth understanding of their characteristics and an appropriate approach to match them. This paper addresses the importance of the design features and annualized performances of the optical subsystem (heliostat-receiver) and the thermal-to-electricity subsystem (solar receiver-energy storage-power block) on the global optimization of any integrated CSP plant. The analysis lies in a complete model of a particle-based CSP plant, which includes detailed modeling for the solar field, a cavity solar receiver with an up bubbling fluidized bed (UBFB) tubular panel, particles storage tanks and a recompression S-CO2 Brayton cycle. The design incident irradiance on the receiver aperture (IR) and the particles temperature at the receiver outlet (T-p) are identified as key parameters determining the solar-to-electric integration procedure and affecting the overall plant design and annual performance. Regarding subsystems located upstream and downstream of the receiver, the effects of heliostat and power block characteristics on the optimal IR and T-p are also evaluated, represented by the heliostat beam quality and main compressor inlet temperature. Results show that IR around 1,200-1,500 W/m(2) provides the maximum system design efficiency and annual efficiency. Improvements on heliostat beam quality and power block efficiency help to increase the optimal IR and overall system efficiency. In the optimal range of IR, increasing T-p leads to higher system design efficiency, but lower system annual efficiency and annual electricity output. The optimal combination of IR and T-p contributes to a minimum heliostat design area, representing the integration trade-off between the system optical and thermal characteristics. (C) 2022 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:164 / 179
页数:16
相关论文
共 50 条
[11]   Novel design measures for optimizing the yearlong performance of a concentrating solar thermal power plant using thermal storage and a dry-cooled supercritical CO2 power block [J].
Ehsan, M. Monjurul ;
Guan, Zhiqiang ;
Gurgenci, Hal ;
Klimenko, Alexander .
ENERGY CONVERSION AND MANAGEMENT, 2020, 216
[12]  
European Comission, 2015, CSP2 CONC SOL POW PA
[13]   Preliminary design and performance analysis of a multi-megawatt scale dense particle suspension receiver [J].
Gallo, A. ;
Spelling, J. ;
Romero, M. ;
Gonzalez-Aguilar, J. .
INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, SOLARPACES 2014, 2015, 69 :388-397
[14]   Shaping High Efficiency, High Temperature Cavity Tubular Solar Central Receivers [J].
Gueguen, Ronny ;
Grange, Benjamin ;
Bataille, Francoise ;
Mer, Samuel ;
Flamant, Gilles .
ENERGIES, 2020, 13 (18)
[15]   Perspective of concentrating solar power [J].
He, Ya-Ling ;
Qiu, Yu ;
Wang, Kun ;
Yuan, Fan ;
Wang, Wen-Qi ;
Li, Ming-Jia ;
Guo, Jia-Qi .
ENERGY, 2020, 198
[16]   Proposal of a new design of source heat exchanger for the technical feasibility of solar thermal plants coupled to supercritical power cycles [J].
Jose Montes, Maria ;
Ignacio Linares, Jose ;
Barbero, Ruben ;
Rovira, Antonio .
SOLAR ENERGY, 2020, 211 :1027-1041
[17]  
Kistler B.L., 1986, Other Inf. Portions this Doc. are illegible Microfich, P231
[18]  
Lauzier N, VIEW FACTORS FILE EX
[19]  
Le Gal A., 2019, THERMAL ANAL FLUIDIZ, DOI [10.1016/j.solener.2019.08.062, DOI 10.1016/J.SOLENER.2019.08.062]
[20]  
Lemmon EW, 2018, NIST ChemistryWebBook