Improved Accuracy of Pulmonary Embolism Computer-Aided Detection Using Iterative Reconstruction Compared With Filtered Back Projection

被引:20
作者
Lahiji, Kian [1 ]
Kligerman, Seth [1 ]
Jeudy, Jean [1 ]
White, Charles [1 ]
机构
[1] Univ Maryland, Med Ctr, Dept Diagnost Radiol & Nucl Med, Baltimore, MD 21201 USA
关键词
computer-aided detection; CT; iterative reconstruction; pulmonary embolism; ASSISTED DETECTION PROTOTYPE; IMAGE QUALITY; CT; ANGIOGRAPHY; PERFORMANCE; DIAGNOSIS; RADIOLOGISTS; TOMOGRAPHY; EXPERIENCE; RADIATION;
D O I
10.2214/AJR.13.11838
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to determine whether use of iterative reconstruction (IR) can improve performance of a pulmonary embolism computer-aided detection (PE CAD) prototype. MATERIALS AND METHODS. Images were collected from 40 consecutive pulmonary CT angiographic examinations in which PE was found and 26 studies in which it was not found for use as control cases. All images were reconstructed with filtered back projection (FBP) and six levels of a hybrid IR algorithm. The studies were evaluated with a prototype PE CAD system, and its performance was comparatively assessed on the basis of reconstruction type on a per-embolus and a per-study basis. RESULTS. Use of the hybrid IR algorithm led to a significant and progressive decrease in false-positive marks made by PE CAD compared with those made by radiologists on FBP reconstructions (239 false-positive marks for FBP and 154, 136, 125, 116, 107, and 98 false-positive marks for the six hybrid IR [HIR] levels). Specificity improved with increasing HIR level (45.6% for level 6; 30.3% for FBP). However, compared with FBP, increasing levels of HIR resulted in a progressive decrease in per-embolism sensitivity (70.3% for FBP; 55.4% for HIR level 6) and, with the exception of HIR level 4, a progressive decrease in per-study sensitivity (97.5% for FBP; 85.0% for HIR level 6). Overall accuracy was highest for HIR level 1 (77.3%). CONCLUSION. The use of IR leads to a significant reduction in false-positive marks by PE CAD at a cost of decreasing sensitivity. Very high levels of IR, which had the lowest sensitivities, should be avoided if being used concomitantly with PE CAD.
引用
收藏
页码:763 / 771
页数:9
相关论文
共 23 条
[1]   Computer-aided detection of solid lung nodules on follow-up MDCT screening: Evaluation of detection, tracking, and reading time [J].
Beigelman-Aubrey, Catherine ;
Raffy, Philippe ;
Yang, Wenjie ;
Castellino, Ronald A. ;
Grenier, Philippe A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (04) :948-955
[2]   Computer-aided detection of pulmonary embolism at CT pulmonary angiography: can it improve performance of inexperienced readers? [J].
Blackmon, Kevin N. ;
Florin, Charles ;
Bogoni, Luca ;
McCain, Joshua W. ;
Koonce, James D. ;
Lee, Heon ;
Bastarrika, Gorka ;
Thilo, Christian ;
Costello, Philip ;
Salganicoff, Marcos ;
Schoepf, U. Joseph .
EUROPEAN RADIOLOGY, 2011, 21 (06) :1214-1223
[3]   Clinical evaluation of a computer-aided diagnosis (CAD) prototype for the detection of pulmonary embolism [J].
Buhmann, Sonja ;
Herzog, Peter ;
Liang, Jin ;
Wolf, Mathias ;
Salganicoff, Marcos ;
Kirchhoff, Chlodwig ;
Reiser, Maximilian ;
Becker, Christoph H. .
ACADEMIC RADIOLOGY, 2007, 14 (06) :651-658
[4]   Assessing the Stand-Alone Sensitivity of Computer-Aided Detection With Cancer Cases From the Digital Mammographic Imaging Screening Trial [J].
Cole, Elodia B. ;
Zhang, Zheng ;
Marques, Helga S. ;
Nishikawa, Robert M. ;
Hendrick, R. Edward ;
Yaffe, Martin J. ;
Padungchaichote, Wittaya ;
Kuzmiak, Cherie ;
Chayakulkheeree, Jatuporn ;
Conant, Emily F. ;
Fajardo, Laurie L. ;
Baum, Janet ;
Gatsonis, Constantine ;
Pisano, Etta .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (03) :W392-W401
[5]   Computer-aided detection of pulmonary embolism:: Influence on radiologists' detection performance with respect to vessel segments [J].
Das, Marco ;
Muehlenbruch, Georg ;
Helm, Anita ;
Bakai, Annemarie ;
Salganicoff, Marcos ;
Stanzel, Sven ;
Liang, Jianming ;
Wolf, Matthias ;
Guenther, Rolf W. ;
Wildberger, Joachim Ernst .
EUROPEAN RADIOLOGY, 2008, 18 (07) :1350-1355
[6]   Computer-assisted detection of pulmonary embolism: performance evaluation in consensus with experienced and inexperienced chest radiologists [J].
Engelke, Christoph ;
Schmidt, Stephan ;
Bakai, Annemarie ;
Auer, Florian ;
Marten, Katharina .
EUROPEAN RADIOLOGY, 2008, 18 (02) :298-307
[7]   Image quality in low-dose coronary computed tomography angiography with a new high-definition CT scanner [J].
Kazakauskaite, Egle ;
Husmann, Lars ;
Stehli, Julia ;
Fuchs, Tobias ;
Fiechter, Michael ;
Klaeser, Bernd ;
Ghadri, Jelena R. ;
Gebhard, Catherine ;
Gaemperli, Oliver ;
Kaufmann, Philipp A. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (02) :471-477
[8]   Use of a Hybrid Iterative Reconstruction Technique to Reduce Image Noise and Improve Image Quality in Obese Patients Undergoing Computed Tomographic Pulmonary Angiography [J].
Kligerman, Seth ;
Mehta, Dhruv ;
Farnadesh, Mahmmoudreza ;
Jeudy, Jean ;
Olsen, Kathryn ;
White, Charles .
JOURNAL OF THORACIC IMAGING, 2013, 28 (01) :49-59
[9]   Acute Pulmonary Embolism [J].
Kuriakose, Jean ;
Patel, Smita .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2010, 48 (01) :31-+
[10]   A study on two different CAD systems for mammography as an aid to radiological diagnosis in the search of microcalcification clusters [J].
Lauria, A ;
Palmiero, R ;
Forni, G ;
Fantacci, ME ;
Imbriaco, M ;
Sodano, A ;
Indovina, PL .
EUROPEAN JOURNAL OF RADIOLOGY, 2005, 55 (02) :264-269