Assessment of potential reduction in multidetector computed tomography doses using FBP and SAFIRE for detection and measurement of the position of the inferior alveolar canal

被引:4
作者
Al-Ekrish, Asma'a Abdurrahman [1 ]
Alzahrani, Adel [1 ]
Zaman, Mahmud U. [1 ]
Alfaleh, Wafa [1 ]
Hoermann, Romed [2 ]
Widmann, Gerlig [3 ]
机构
[1] King Saud Univ, Coll Dent, Riyadh, Saudi Arabia
[2] Med Univ Innsbruck, Div Clin & Funct Anat, Innsbruck, Austria
[3] Med Univ Innsbruck, Dept Radiol, Innsbruck, Austria
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY | 2020年 / 129卷 / 01期
关键词
GOVERNING BODY DONATION; CT; MDCT; IMAGES; EUROPE; LEGAL; ASIR; CBCT;
D O I
10.1016/j.oooo.2019.09.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The objective was to identify the lowest doses required to detect and measure the position of the inferior alveolar canal (IAC) on multidetector computed tomography (MDCT) images using filtered backprojection (FBP) and sinogram-affirmed iterative reconstructions (SAFIRE) 3 and SAFIRE 5. Study Design. Four cadaveric mandibles were imaged using a reference protocol with standard dose and FBP and 3 ultra-lowdose protocols (LD1-LD3), using an MDCT scanner. All test examinations were reconstructed with FBP, SAFIRE 3, and SAFIRE 5. Subjective visibility of the IAC in the images and digital measurements of the height of the ridge above the IAC were recorded from test images and compared with those from the reference image using one-sample t tests, Bland-Altman plots, and linear regression. Results. Subjective visibility comparable to the standard protocol was obtained with an 84.6% dose reduction using the LD2 protocol. No statistically significant difference was found between the height measurements from the reference protocol and any of the LD1 and LD2 protocols. The t tests indicated a significant difference between the measurements from the reference and all LD3 test protocols. SAFIRE did not have an advantage over FBP images. Conclusions. Significant dose reduction from the reference dose can allow adequate detection and measurements of the IAC.
引用
收藏
页码:65 / +
页数:14
相关论文
共 23 条
  • [1] A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions
    Al-Ekrish, A. A.
    Ekram, M.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (02) : 67 - 75
  • [2] Do Ultra-Low Multidetector Computed Tomography Doses and Iterative Reconstruction Techniques Affect Subjective Classification of Bone Type at Dental Implant Sites?
    Al-Ekrish, Asma'a A.
    Alfadda, Sara A.
    Tamimi, Dania
    Alfaleh, Wafa
    Hoermann, Romed
    Puelacher, Wolfgang
    Widmann, Gerlig
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (05) : 465 - +
  • [3] Accuracy of computer-aided design models of the jaws produced using ultra-low MDCT doses and ASIR and MBIR
    Al-Ekrish, Asma'a A.
    Alfadda, Sara A.
    Ameen, Wadea
    Hoermann, Romed
    Puelacher, Wolfgang
    Widmann, Gerlig
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (11) : 1853 - 1860
  • [4] Validity of linear measurements of the jaws using ultralow-dose MDCT and the iterative techniques of ASIR and MBIR
    Al-Ekrish, Asma'a A.
    Al-Shawaf, Reema
    Schullian, Peter
    Al-Sadhan, Ra'ed
    Hormann, Romed
    Widmann, Gerlig
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (10) : 1791 - 1801
  • [5] Comparability of dental implant site ridge measurements using ultra-low-dose multidetector row computed tomography combined with filtered back-projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction
    Al-Ekrish, Asma'a Abdurrahman
    Al-Shawaf, Reema
    Alfaleh, Wafa
    Hoermann, Romed
    Puelacher, Wolfgang
    Widmann, Gerlig
    [J]. ORAL RADIOLOGY, 2019, 35 (03) : 280 - 286
  • [6] Localization of the inferior alveolar canal using ultralow dose CT with iterative reconstruction techniques
    Al-Ekrish, Asmaa A.
    Alfaleh, Wafa
    Hoermann, Romed
    Alabdulwahid, Ameera
    Puelacher, Wolfgang
    Widmann, Gerlig
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2018, 47 (08)
  • [7] Contrast-to-Noise Ratio and Low-Contrast Object Resolution on Full- and Low-Dose MDCT: SAFIRE Versus Filtered Back Projection in a Low-Contrast Object Phantom and in the Liver
    Baker, Mark E.
    Dong, Frank
    Primak, Andrew
    Obuchowski, Nancy A.
    Einstein, David
    Gandhi, Namita
    Herts, Brian R.
    Purysko, Andrei
    Remer, Erick
    Vachani, Neil
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (01) : 8 - 18
  • [8] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [9] Principles of CT: Multislice CT
    Goldman, Lee W.
    [J]. JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2008, 36 (02) : 57 - 68
  • [10] CT effective dose per dose length product using ICRP 103 weighting factors
    Huda, Walter
    Magill, Dennise
    He, Wenjun
    [J]. MEDICAL PHYSICS, 2011, 38 (03) : 1261 - 1265