A new strategy of solution calibration in laser ablation inductively coupled plasma mass spectrometry for multielement trace analysis of geological samples

被引:74
作者
Pickhardt, C [1 ]
Becker, JS [1 ]
Dietze, HJ [1 ]
机构
[1] Forschungszentrum Julich, Zentral Abt Chem Analysen, D-52425 Julich, Germany
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2000年 / 368卷 / 2-3期
关键词
D O I
10.1007/s002160000485
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Because multielement trace analysis by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is often limited by the lack of suitable reference materials with a similar matrix composition, a novel quantification strategy using solution calibration was developed. For mass spectrometric multielement determination in geological samples a quadrupole-based LA-ICP-MS is coupled with an ultrasonic nebulizer (USN). In order to arrange matrix matching the standard solutions are nebulized with a USN during solution calibration and simultaneously a blank target (e.g. lithium borate) is ablated with a focused laser beam. The homogeneous geological samples were measured using the same experimental arrangement where a 2% nitric acid is simultaneously nebulized with the USN. Homogeneous targets were prepared from inhomogeneous geological samples by powdering, homogenizing and fusing with a lithium borate mixture in a muffle furnace at 1050 degrees C. Furthermore, a homogeneous geological glass was also investigated. The quantification of analytical results was performed by external calibration using calibration curves measured on standard solutions. In order to compare two different approaches for the quantification of analytical results in LA-ICP-MS, measured concentrations in homogeneous geological targets were also corrected with relative sensitivity coefficients (RSCs) determined using one standard solution only. The analytical results of LA-ICP-MS on various geological samples are in good agreement with the reference values and the results of other trace analytical methods. The relative standard deviation (RSD) for trace element determination (N = 6) is between 2 and 10%.
引用
收藏
页码:173 / 181
页数:9
相关论文
共 30 条
[1]   Analysis of silicon nitride bearings with laser ablation inductively coupled plasma mass spectrometry [J].
Baker, SA ;
Dellavecchia, MJ ;
Smith, BW ;
Winefordner, JD .
ANALYTICA CHIMICA ACTA, 1997, 355 (2-3) :113-119
[2]   Trace and ultratrace analysis of gallium arsenide by different mass spectrometric techniques [J].
Becker, JS ;
Soman, RS ;
Becker, T ;
Panday, VK ;
Dietze, HJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) :983-987
[3]   Mass spectrometric analysis of ceramic components for solid oxide fuel cells [J].
Becker, JS ;
Westheide, J ;
Saprykin, AI ;
Holzbrecher, H ;
Breuer, U ;
Dietze, HJ .
MIKROCHIMICA ACTA, 1997, 125 (1-4) :153-160
[4]  
Becker JS, 1996, FRESEN J ANAL CHEM, V355, P626
[5]   Inorganic mass spectrometric methods for trace, ultratrace, isotope, and surface analysis [J].
Becker, JS ;
Dietze, HJ .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 197 :1-35
[6]   Determination of trace elements in geological samples by laser ablation inductively coupled plasma mass spectrometry [J].
Becker, JS ;
Dietze, HJ .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (05) :429-434
[7]  
BECKER JS, 1999, EUR WINT C PLASM SPE
[8]  
BECKER JS, 1998, ADV MASS SPECTROMETR, V14
[9]  
BECKER JS, 2000, IN PRESS MIKROCHIM A
[10]   Trace element microanalysis in iron meteorites by laser ablation ICPMS [J].
Campbell, AJ ;
Humayun, M .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :939-946