Suppressing bubble shielding effect in shock wave lithotripsy by low intensity pulsed ultrasound

被引:11
作者
Wang, Jen-Chieh [1 ]
Zhou, Yufeng [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
关键词
Shock wave lithotripsy (SWL); Cavitation; Bubble shielding effect; Low-intensity pulsed ultrasound (LIPUS); Acoustic radiation force; CAVITATION CLUSTER DYNAMICS; IN-VITRO; STONE FRAGMENTATION; KIDNEY-STONES; EXTRACORPOREAL LITHOTRIPSY; CLINICAL-EXPERIENCE; DIABETES-MELLITUS; ACOUSTIC-EMISSION; RADIATION FORCE; COMMINUTION;
D O I
10.1016/j.ultras.2014.08.004
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Extracorporeal shock wave lithotripsy (ESWL) has been used as an effective modality to fragment kidney calculi. Because of the bubble shielding effect in the pre-focal region, the acoustic energy delivered to the focus is reduced. Low pulse repetition frequency (PRF) will be applied to dissolve these bubbles for better stone comminution efficiency. In this study, low intensity pulsed ultrasound (LIPUS) beam was aligned perpendicular to the axis of a shock wave (SW) lithotripter at its focus. The light transmission was used to evaluate the compressive wave and cavitation induced by SWs without or with a combination of LIPUS for continuous sonication. It is found that bubble shielding effect becomes dominated with the SW exposure and has a greater significant effect on cavitation than compressive wave. Using the combined wave scheme, the improvement began at the 5th pulse and gradually increased. Suppression effect on bubble shielding is independent on the trigger delay, but increases with the acoustic intensity and pulse duration of LIPUS. The peak negative and integral area of light transmission signal, which present the compressive wave and cavitation respectively, using our strategy at PRF of 1 Hz are comparable to those using SW alone at PRF of 0.1 Hz. In addition, high-speed photography confirmed the bubble activities in both free field and close to a stone surface. Bubble motion in response to the acoustic radiation force by LIPUS was found to be the major mechanism of suppressing bubble shielding effect. There is a 2.6-fold increase in stone fragmentation efficiency after 1000 SWs at PRF of 1 Hz in combination with LIPUS. In summary, combination of SWs and LIPUS is an effective way of suppressing bubble shielding effect and, subsequently, improving cavitation at the focus for a better outcome. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:65 / 74
页数:10
相关论文
共 54 条
[11]   ACOUSTIC CAVITATION SERIES .5. RECTIFIED DIFFUSION [J].
CRUM, LA .
ULTRASONICS, 1984, 22 (05) :215-223
[13]   The magnitude of radiation force on ultrasound contrast agents [J].
Dayton, PA ;
Allen, JS ;
Ferrara, KW .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2002, 112 (05) :2183-2192
[14]   Active Removal of Residual Bubble Nuclei Following a Cavitation Event [J].
Duryea, Alexander P. ;
Cain, Charles A. ;
Roberts, William W. ;
Tamaddoni, Hedieh A. ;
Hall, Timothy L. .
2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, :1813-1816
[15]   Acoustic Bubble Removal to Enhance SWL Efficacy at High Shock Rate: An In Vitro Study [J].
Duryea, Alexander P. ;
Roberts, William W. ;
Cain, Charles A. ;
Tamaddoni, Hedieh A. ;
Hall, Timothy L. .
JOURNAL OF ENDOUROLOGY, 2014, 28 (01) :90-95
[16]   The mechanisms of stone fragmentation in ESWL [J].
Eisenmenger, W .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (05) :683-693
[17]   Renal trauma and the risk of long-term complications in shock wave lithotripsy [J].
Evan, AP ;
Willis, LR ;
Lingeman, JE ;
McAteer, JA .
NEPHRON, 1998, 78 (01) :1-8
[18]   Does the rate of extracorporeal shock wave delivery affect stone fragmentation? [J].
Greenstein, A ;
Matzkin, H .
UROLOGY, 1999, 54 (03) :430-432
[19]   Effects of Gas Pockets on High-Intensity Focused Ultrasound Field [J].
Hosseini, S. Hamid R. ;
Zheng, Xinliang ;
Vaezy, Shahram .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (06) :1203-1210
[20]   Improvement of stone comminution by slow delivery rate of shock waves in extracorporeal lithotripsy [J].
Kato, Yuji ;
Yamaguchi, Satoshi ;
Hori, Junichi ;
Okuyama, Mitsuhiko ;
Kakizaki, Hidehiro .
INTERNATIONAL JOURNAL OF UROLOGY, 2006, 13 (12) :1461-1465