Fully automatic quantification of transient severe respiratory motion artifact of gadoxetate disodium-enhanced MRI during arterial phase

被引:2
|
作者
Jang, Jinseong [1 ]
Chung, Yong Eun [2 ]
Kim, Sungwon [2 ]
Hwang, Dosik [1 ,2 ,3 ,4 ,5 ]
机构
[1] Yonsei Univ, Sch Elect & Elect Engn, 50 Yonsei Ro, Seoul 03722, South Korea
[2] Yonsei Univ, Coll Med, Dept Radiol, Seoul, South Korea
[3] Yonsei Univ, Coll Med, Ctr Clin Imaging Data Sci CCIDS, Seoul, South Korea
[4] Yonsei Univ, Coll Dent, Dept Oral & Maxillofacial Radiol, Seoul, South Korea
[5] Korea Inst Sci & Technol, Ctr Healthcare Robot, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
gadoxetate disodium; image quality assessment; motion artifact; transient severe respiratory motion; GD-EOB-DTPA; IMAGE QUALITY ASSESSMENT; REDUCING ARTIFACTS; DILUTION METHOD; PRIOR EPISODE; ACID; REDUCTION;
D O I
10.1002/mp.15831
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose It is important to fully automate the evaluation of gadoxetate disodium-enhanced arterial phase images because the efficient quantification of transient severe motion artifacts can be used in a variety of applications. Our study proposes a fully automatic evaluation method of motion artifacts during the arterial phase of gadoxetate disodium-enhanced MR imaging. Methods The proposed method was based on the construction of quality-aware features to represent the motion artifact using MR image statistics and multidirectional filtered coefficients. Using the quality-aware features, the method calculated quantitative quality scores of gadoxetate disodium-enhanced images fully automatically. The performance of our proposed method, as well as two other methods, was acquired by correlating scores against subjective scores from radiologists based on the 5-point scale and binary evaluation. The subjective scores evaluated by two radiologists were severity scores of motion artifacts in the evaluation set on a scale of 1 (no motion artifacts) to 5 (severe motion artifacts). Results Pearson's linear correlation coefficient (PLCC) and Spearman's rank-ordered correlation coefficient (SROCC) values of our proposed method against the subjective scores were 0.9036 and 0.9057, respectively, whereas the PLCC values of two other methods were 0.6525 and 0.8243, and the SROCC values were 0.6070 and 0.8348. Also, in terms of binary quantification of transient severe respiratory motion, the proposed method achieved 0.9310 sensitivity, 0.9048 specificity, and 0.9200 accuracy, whereas the other two methods achieved 0.7586, 0.8996 sensitivities, 0.8098, 0.8905 specificities, and 0.9200, 0.9048 accuracies Conclusions This study demonstrated the high performance of the proposed automatic quantification method in evaluating transient severe motion artifacts in arterial phase images.
引用
收藏
页码:7247 / 7261
页数:15
相关论文
共 38 条
  • [1] Characterization of Severe Arterial Phase Respiratory Motion Artifact on Gadoxetate Disodium-Enhanced MRI - Assessment of Interrater Agreement and Reliability
    Ringe, Kristina Imeen
    Luetkens, Julian A.
    Fimmers, Rolf
    Hammerstingl, Renate Maria
    Layer, Guenter
    Maurer, Martin H.
    Naehle, Claas Philip
    Michalik, Sabine
    Reimer, Peter
    Schraml, Christina
    Schreyer, Andreas G.
    Stumpp, Patrick
    Vogl, Thomas J.
    Wacker, Frank K.
    Willinek, Winfried
    Kukuk, Guido Mattias
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2018, 190 (04): : 341 - 347
  • [2] Transient Respiratory Motion Artifact During Arterial Phase MRI With Gadoxetate Disodium: Risk Factor Analyses
    Kim, So Yeon
    Park, Seong Ho
    Wu, En-Haw
    Wang, Z. Jane
    Hope, Thomas A.
    Chang, Wei-Chou
    Yeh, Benjamin M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (06) : 1220 - 1227
  • [3] Transient Severe Motion Artifact Related to Gadoxetate Disodium-Enhanced Liver MRI: Frequency and Risk Evaluation at a German Institution
    Well, Lennart
    Rausch, Vanessa Hanna
    Adam, Gerhard
    Henes, Frank Oliver
    Bannas, Peter
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2017, 189 (07): : 651 - 660
  • [4] Transient Respiratory-motion Artifact and Scan Timing during the Arterial Phase of Gadoxetate Disodium-enhanced MR Imaging: The Benefit of Shortened Acquisition and Multiple Arterial Phase Acquisition
    Ichikawa, Shintaro
    Motosugi, Utaroh
    Sato, Kazuyuki
    Shimizu, Tatsuya
    Wakayama, Tetsuya
    Onishi, Hiroshi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (03) : 280 - 289
  • [5] Reducing transient severe motion artifacts of gadoxetate disodium-enhanced MRI by oxygen inhalation: effective for pleural effusion but not ascites
    Jia, Xiaoqian
    Li, Xianjun
    Wei, Xiaocheng
    Sun, Jingtao
    Han, Yangyang
    Guo, Ming
    Tong, Wei
    Qu, Yuan
    Zhu, Shumeng
    Guo, Jianxin
    ABDOMINAL RADIOLOGY, 2024, 49 (12) : 4584 - 4591
  • [6] Gadoxetate disodium-enhanced MRI: Assessment of arterial phase artifacts and hepatobiliary uptake in a large series
    Violi, Naik Vietti
    Argiriadi, Pamela
    Rosen, Ally
    Cherny, Mathew
    Weiss, Amanda
    Hernandez-Meza, Gabriela
    Babb, James S.
    Kihira, Shingo
    Lewis, Sara
    Taouli, Bachir
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 132
  • [7] Transient severe motion in the arterial phase during gadoxetate disodium-enhanced MR imaging: evaluation of patients with multiple MR examinations
    Im, Won Hyeong
    Song, Ji Soo
    Park, Eun Hae
    Kwak, Hyo Sung
    ABDOMINAL RADIOLOGY, 2017, 42 (10) : 2393 - 2401
  • [8] Transient severe motion in the arterial phase during gadoxetate disodium-enhanced MR imaging: evaluation of patients with multiple MR examinations
    Won Hyeong Im
    Ji Soo Song
    Eun Hae Park
    Hyo Sung Kwak
    Abdominal Radiology, 2017, 42 : 2393 - 2401
  • [9] Evaluation of transient respiratory motion artifact at gadoxetate disodium-enhanced MRI-Influence of different contrast agent application protocols
    Ringe, Kristina, I
    von Falck, Christian
    Raatschen, Hans-Juergen
    Wacker, Frank
    Hinrichs, Jan
    PLOS ONE, 2018, 13 (07):
  • [10] Dose-Toxicity Relationship of Gadoxetate Disodium and Transient Severe Respiratory Motion Artifact
    Davenport, Matthew S.
    Bashir, Mustafa R.
    Pietryga, Jason A.
    Weber, Joseph T.
    Khalatbari, Shokoufeh
    Hussain, Hero K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (04) : 796 - 802