Distal biceps tendon repair: comparison of clinical and radiological outcome between bioabsorbable and nonabsorbable screws

被引:11
作者
Caekebeke, Pieter [1 ]
Corten, Kristoff [1 ]
Duerinckx, Joris [1 ]
机构
[1] Ziekenhuis Oost Limburg, Dept Orthopaed, Genk, Belgium
关键词
Biceps tendon; osteolysis; PLLA; PEEK; interference; repair; ANTERIOR CRUCIATE LIGAMENT; DOUBLE-INCISION TECHNIQUE; INTERFERENCE SCREW; CORTICAL BUTTON; BRACHII TENDON; TUNNEL ENLARGEMENT; BONE TUNNEL; FIXATION; RUPTURE; RECONSTRUCTION;
D O I
10.1016/j.jse.2015.12.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Distal biceps tendon repair to the radial tuberosity can be conducted by means of an interference screw in combination with a transosseous button. Bioabsorbable interference screws have been associated with complications such as severe osteolytic reactions. We questioned whether patients with a distal biceps tendon repair with bioabsorbable poly-L-lactide (PLLA) screws had different functional, clinical, and radiologic outcome than patients with nonabsorbable poly-ether ether ketone (PEEK) screws. Methods: Between 2010 and 2014, 23 patients with an acute distal biceps tendon rupture were treated with reinsertion of the distal biceps tendon in a bone tunnel at the radial tuberosity through a single anterior incision using a transosseous button combined with an interference screw. A PLLA screw was used in 12 patients and a PEEK screw in 11 patients. All patients were retrospectively evaluated with a minimal follow-up of 1 year clinically and by means of the visual analog scale for pain, Mayo Elbow Performance Score, and Disabilities of Arm, Shoulder and Hand Outcome Measure score. Bone tunnel volume was measured with computed tomography segmentation. Results: Elbow mobility and arm and forearm circumference were symmetric for all patients. The visual analog scale for pain was 0.2 in the PLLA group and 0.7 in the PEEK group. The Disabilities of Arm, Shoulder and Hand score and Mayo Elbow Performance Score were 5.4 and 98.7 in the PLLA group vs. 3.1 and 95.9 in the PEEK group. Bone tunnel enlargement of 43% in the PLLA and 38% in the PEEK group was noted. Conclusions: Clinical and functional outcome at more than 1 year after distal biceps tendon repair was excellent in both groups. Bone tunnel widening occurred in all patients. (C) 2016 Journal of Shoulder and Elbow Surgery Board of Trustees
引用
收藏
页码:349 / 354
页数:6
相关论文
共 52 条
[1]   Bioabsorbable implants: Review of clinical experience in orthopedic surgery [J].
Ambrose, CG ;
Clanton, TO .
ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (01) :171-177
[2]  
Bain GI, 2000, J SHOULDER ELB SURG, V9, P120
[3]   RUPTURE OF THE DISTAL TENDON OF THE BICEPS BRACHII - OPERATIVE VERSUS NON-OPERATIVE TREATMENT [J].
BAKER, BE ;
BIERWAGEN, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (03) :414-417
[4]  
Barber FA, 2000, BIOMATERIALS, V21, P2623
[5]   FOREIGN-BODY REACTIONS TO RESORBABLE POLY(L-LACTIDE) BONE PLATES AND SCREWS USED FOR THE FIXATION OF UNSTABLE ZYGOMATIC FRACTURES [J].
BERGSMA, EJ ;
ROZEMA, FR ;
BOS, RRM ;
DEBRUIJN, WC .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (06) :666-670
[6]  
Blasier R D, 1997, Instr Course Lect, V46, P531
[7]   Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation:: a review [J].
Böstman, O ;
Pihlajamäki, H .
BIOMATERIALS, 2000, 21 (24) :2615-2621
[8]  
Böstman OM, 2000, CLIN ORTHOP RELAT R, P216
[9]   A prospective evaluation of tunnel enlargement in anterior cruciate ligament reconstruction with hamstrings: extracortical versus anatomical fixation [J].
Buelow, JU ;
Siebold, R ;
Ellermann, A .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2002, 10 (02) :80-85
[10]   Rupture of the distal biceps brachii tendon: conservative treatment versus anatomic reinsertion - clinical and radiological evaluation after 2 years [J].
Chillemi, Claudio ;
Marinelli, Mario ;
De Cupis, Vincenzo .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (08) :705-708