On the Application of Vickers Micro Hardness Testing to Isotactic Polypropylene

被引:16
|
作者
Wu, Hao [1 ]
Dave, Foram [2 ]
Mokhtari, Mozaffar [3 ,4 ,5 ]
Ali, Muhammad Mahmood [2 ]
Sherlock, Richard [6 ]
McIlhagger, Alistair [5 ]
Tormey, David [2 ]
McFadden, Shaun [1 ]
机构
[1] Ulster Univ, Sch Comp Engn & Intelligent Syst, Coleraine BT48 7JL, Londonderry, North Ireland
[2] Inst Technol Sligo, Ctr Precis Engn Mat & Mfg Res, Dept Mech & Mfg Engn, Sligo F91 YW50, Ireland
[3] Univ Manchester, Sch Nat Sci, Natl Graphene Inst, Manchester M13 9PL, Lancs, England
[4] Univ Manchester, Sch Nat Sci, Dept Mat, Manchester M13 9PL, Lancs, England
[5] Ulster Univ, Sch Engn, Newtownabbey BT37 0QB, North Ireland
[6] Inst Technol Sligo, Dept Life Sci, Sligo F91 YW50, Ireland
基金
美国国家卫生研究院;
关键词
isotactic polypropylene; Vickers hardness; carbon black addition; CARBON-BLACK; MICROHARDNESS; BETA;
D O I
10.3390/polym14091804
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Hardness is a useful measure of a material's resistance to permanent indentation; but for viscoelastic polymers, hardness data are highly dependent on the test type and the parameter set chosen. Vickers microhardness testing is used to leave small indents (<150 mu m) and is shown to be applicable to polymers. A detailed investigation of the required steps for microhardness testing in isotactic polypropylene (iPP) is provided. Samples should be mounted in epoxy resin in order to maintain curing temperatures at room temperature. Mounted samples can be ground and polished in a semi-automatic polisher using graduated SiC paper (wet grinding) but progressing onto alumina suspension for polishing. Final polishing should be performed with 0.05-mu m alumina suspension. The hardness measured was shown to be dependent on load and dwell time with a much greater dependency on dwell time. Strain recovery was shown to be completed after a time period equal to the dwell time. This study shows that indents can be measured thereafter, and it is recommended that they be measured within a 24 h period after the indent was created. After data fitting, the equation for hardness was shown to follow a power law with load and dwell time as the main variables. Fitting parameters were compared to those found in the literature, and it was found that parameters were significantly different to those reported elsewhere. Therefore, this study highlights the importance of calibrating on a case-by-case basis. Finally, to show the usefulness of the Vickers micro-hardness testing method, the calibrated test method was applied on iPP with additions of carbon black up to 3 wt.%. Comparisons were made with data from the literature, but the hardness data generated in our work were found to be at least twice that reported in the literature. The testing parameters were not cited in the literature: specifically, the dwell time was not provided, and this generated doubt on the usefulness of the cited data. Hence, this work is intended to serve as an exemplar of how to prepare and proceed with hardness testing of polymers.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] The morphology of irradiated isotactic polypropylene
    Zhang, XC
    Cameron, RE
    JOURNAL OF APPLIED POLYMER SCIENCE, 1999, 74 (09) : 2234 - 2242
  • [22] The Relation of the Vickers Hardness With the Loading Stiffness of Instrumented Vickers Indentation of Metal Substrates
    Baxevani, E. A.
    Giannakopoulos, A. E.
    JOURNAL OF ENGINEERING MATERIALS AND TECHNOLOGY-TRANSACTIONS OF THE ASME, 2010, 132 (03): : 0345011 - 0345015
  • [23] Method for Identifying Vickers Hardness by Instrumented Indentation Curves with Berkovich/Vickers Indenter
    D. J. Ma
    J. L. Wang
    L. Sun
    Y. Huang
    Experimental Mechanics, 2016, 56 : 891 - 901
  • [24] The β-crystalline form of isotactic polypropylene in blends of isotactic polypropylene and polyamide-6/clay nanocomposites
    Feng, M
    Gong, FL
    Zhao, CG
    Chen, GM
    Zhang, SM
    Yang, MS
    Han, CC
    JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 2004, 42 (18) : 3428 - 3438
  • [25] Effect of the foreign ions on Vickers micro-hardness of the crystalline phases in the co-processed clinkers
    de Souza, Vladia Cristina G.
    Koppe, Jair Carlos
    Coimbra Leite Costa, Joao Felipe
    REM-REVISTA ESCOLA DE MINAS, 2010, 63 (02) : 299 - 306
  • [26] Weightings on the Propagation of Errors in the Vickers Hardness Parameters
    Thiago de Lima Gontarski
    Aline Peres Leal
    Rafael Machado Casali
    Sandro Elias Braun
    Paulo Soares
    André Luís Condino Fujarra
    Alexandre Mikowski
    Brazilian Journal of Physics, 2022, 52
  • [27] Morphology design of isotactic polypropylene composites: From "sandwich" film to injection application
    Wang, Shiwei
    Leng, Yuting
    Zhang, Guangan
    Wang, Ruonan
    Ma, Shuaijiang
    Li, Qian
    JOURNAL OF THERMOPLASTIC COMPOSITE MATERIALS, 2018, 31 (09) : 1252 - 1262
  • [28] Preparation, Characterization of Substituted Aromatic Heterocyclic Phosphate Salts and the Application in Isotactic Polypropylene
    Long, Lijuan
    He, Wentao
    Zhang, Minmin
    Zhang, Kai
    He, Min
    Qin, Shuhao
    Yu, Jie
    ADVANCES IN MATERIALS AND MATERIALS PROCESSING, PTS 1-3, 2013, 652-654 : 463 - 469
  • [29] β-modification of isotactic polypropylene induced by electrospun isotactic polystyrene fibers
    Wang, Chi
    Lee, Jheng Lin
    Landingin, Junard
    Ko, Chia-Hsin
    POLYMER, 2019, 176 : 236 - 243
  • [30] Facile functionalization of isotactic polypropylene by azide and alkyne groups for click chemistry application
    Zhang, Chuanhui
    Niu, Hui
    Dong, Jin-Yong
    APPLIED ORGANOMETALLIC CHEMISTRY, 2011, 25 (08) : 632 - 637