Resonant laser ionization mass spectrometry: An alternative to AMS?

被引:44
作者
Wendt, K
Trautmann, N
Bushaw, BA
机构
[1] Univ Mainz, Inst Phys, D-55099 Mainz, Germany
[2] Univ Mainz, Inst Kernchem, D-55128 Mainz, Germany
[3] Pacific NW Natl Lab, Richland, WA 99352 USA
关键词
ultratrace detection; resonance ionization spectroscopy; mass spectrometry;
D O I
10.1016/S0168-583X(00)00127-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Resonant laser ionization mass spectrometry (RIMS) has developed into a versatile experimental method particularly concerning applications for highly selective ultratrace analysis. Apart from providing nearly complete isobaric suppression and high overall efficiency, the possibility for combining optical isotopic selectivity with that of the mass spectrometer leads to remarkable specifications. The widespread analytical potential and applicability of different techniques based on resonant laser ionization is demonstrated in investigations on stable and radioactive ultratrace isotopes with the focus on applications which require high selectivity, concerning, e.g., the noble gas isotopes Kr-81,Kr-85, PU isotopes, Sr-89,Sr-90, Tc-99 and Ca-41. Selective ultratrace determination of these radioisotopes provides access to a variety of fundamental research problems in environmental sciences, geo- and cosmochemistry, archaeology and biomedicine, which previously were often an exclusive domain for accelerator mass spectrometry (AMS), (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:162 / 169
页数:8
相关论文
共 30 条
[1]   A METHOD OF DETECTING THE RARE ISOTOPES KR-85 AND KR-81 BY MEANS OF COLLINEAR LASER PHOTOIONIZATION OF ATOMS IN AN ACCELERATED BEAM [J].
ASEYEV, SA ;
KUDRYAVTSEV, YA ;
LETOKHOV, VS ;
PETRUNIN, VV .
JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 1991, 24 (11) :2755-2763
[2]   ATTA - A new method of ultrasensitive isotope trace analysis [J].
Bailey, K ;
Chen, CY ;
Du, X ;
Li, YM ;
Lu, ZT ;
O'Connor, TP ;
Young, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 172 :224-227
[3]   Properties and performance of a quadrupole mass filter used for resonance ionization mass spectrometry [J].
Blaum, K ;
Geppert, C ;
Müller, P ;
Nörtershäuser, W ;
Otten, EW ;
Schmitt, A ;
Trautmann, N ;
Wendt, K ;
Bushaw, BA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 181 :67-87
[4]  
Blaum K, 1998, AIP CONF PROC, V454, P275, DOI 10.1063/1.57159
[5]   Lineshapes and optical selectivity in high-resolution double-resonance ionization mass spectrometry [J].
Bushaw, BA ;
Nörtershäuser, W ;
Wendt, K .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (02) :321-332
[6]  
BUSHAW BA, 1989, PROG ANAL SPECTROSC, V12, P247
[7]   Diode laser based resonance ionization mass spectrometric measurement of strontium-90 [J].
Bushaw, BA ;
Cannon, BD .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (12) :1839-1854
[8]  
Bushaw BA, 1998, AIP CONF PROC, V454, P177, DOI 10.1063/1.57149
[9]  
BUSHAW BA, 1992, I PHYS C SER, V128, P31
[10]  
Collon P, 1999, RADIOCHIM ACTA, V85, P13