Whole-body MRI for metastatic cancer detection using T2-weighted imaging with fat and fluid suppression

被引:8
作者
Wang, Xinzeng [1 ]
Pirasteh, Ali [1 ]
Brugarolas, James [2 ,3 ]
Rofsky, Neil M. [1 ,4 ]
Lenkinski, Robert E. [1 ,4 ]
Pedrosa, Ivan [1 ,2 ,4 ]
Madhuranthakam, Ananth J. [1 ,4 ]
机构
[1] Univ Texas Southwestern Med Ctr Dallas, Dept Radiol, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
[2] Univ Texas Southwestern Med Ctr Dallas, Simmons Comprehens Canc Ctr, Kidney Canc Program, Dallas, TX 75390 USA
[3] Univ Texas Southwestern Med Ctr Dallas, Dept Internal Med, Dallas, TX USA
[4] UT Southwestern Med Ctr, Adv Imaging Res Ctr, Dallas, TX USA
基金
美国国家卫生研究院;
关键词
fat suppression; fluid suppression; metastatic cancer; whole-body imaging; FAST SPIN-ECHO; BONE-SCINTIGRAPHY; RELAXATION-TIMES; FDG-PET/CT; 3.0; T; DWI; TUMORS; CONSPICUOUSNESS; EXPERIENCE; CARCINOMA;
D O I
10.1002/mrm.27117
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a whole-body MRI technique at 3T with improved lesion conspicuity for metastatic cancer detection using fast, high-resolution and high SNR T-2-weighted (T2W) imaging with simultaneous fat and fluid suppression. Theory and Methods: The proposed dual-echo T-2-weighted acquisition for enhanced conspicuity of tumors (DETECT) acquires 4 images, in-phase (IP) and out-of-phase (OP) at a short and a long TE using single-shot turbo spin echo. The IP/OP images at the short and long TEs are reconstructed using the standard Dixon and shared-field-map Dixon reconstruction respectively, for robust fat-water separation. An adaptive complex subtraction between the 2 TE water-only images achieves fluid attenuation. DETECT imaging was optimized and evaluated in whole-body imaging of 5 healthy volunteers, and compared against diffusion-weighted imaging with background suppression (DWIBS) in 5 patients with known metastatic renal cell carcinoma. Results: Robust fat-water separation and fluid attenuation were achieved using the shared-field-map Dixon reconstruction and adaptive complex subtraction, respectively. DETECT imaging technique generated co-registered T2W images with and without fat suppression, heavily T2W, and fat and fluid suppressed T2W whole-body images in < 7 min. Compared to DWIBS acquired in 17 min, the DETECT imaging achieved better detection and localization of lesions in patients with metastatic cancer. Conclusion: DETECT imaging technique generates T2W images with high resolution, high SNR, minimal geometric distortions, and provides good lesion conspicuity with robust fat and fluid suppression in < 7 min for whole-body imaging, demonstrating efficient and reliable metastatic cancer detection at 3T.
引用
收藏
页码:1402 / 1415
页数:14
相关论文
共 43 条
  • [1] Accuracy of whole-body dual-modality fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography and computed tomography (FDG-PET/CT) for tumor staging in solid tumors: Comparison with CT and PET
    Antoch, G
    Saoudi, N
    Kuehl, H
    Dahmen, G
    Mueller, SP
    Beyer, T
    Bockisch, A
    Debatin, JF
    Freudenberg, LS
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2004, 22 (21) : 4357 - 4368
  • [2] MR Fingerprinting of Adult Brain Tumors: Initial Experience
    Badve, C.
    Yu, A.
    Dastmalchian, S.
    Rogers, M.
    Ma, D.
    Jiang, Y.
    Margevicius, S.
    Pahwa, S.
    Lu, Z.
    Schluchter, M.
    Sunshine, J.
    Griswold, M.
    Sloan, A.
    Gulani, V.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (03) : 492 - 499
  • [3] Two-point Dixon Method With Flexible Echo Times
    Berglund, Johan
    Ahlstroem, Hakan
    Johansson, Lars
    Kullberg, Joel
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) : 994 - 1004
  • [4] Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo
    Busse, Reed F.
    Brau, Anja C. S.
    Vu, Anthony
    Michelich, Charles R.
    Bayram, Ersin
    Kijowski, Richard
    Reeder, Scott B.
    Rowley, Howard A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) : 640 - 649
  • [5] MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results
    de Bazelaire, CMJ
    Duhamel, GD
    Rofsky, NM
    Alsop, DC
    [J]. RADIOLOGY, 2004, 230 (03) : 652 - 659
  • [6] Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System
    Del Grande, Filippo
    Santini, Francesco
    Herzka, Daniel A.
    Aro, Michael R.
    Dean, Cooper W.
    Gold, Garry E.
    Carrino, John A.
    [J]. RADIOGRAPHICS, 2014, 34 (01) : 217 - 233
  • [7] Dual-Echo Dixon Imaging with Flexible Choice of Echo Times
    Eggers, Holger
    Brendel, Bernhard
    Duijndam, Adri
    Herigault, Gwenael
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (01) : 96 - 107
  • [8] Whole-Body MRI Including Diffusion-Weighted Imaging (DWI) for Patients With Recurring Prostate Cancer: Technical Feasibility and Assessment of Lesion Conspicuity in DWI
    Eiber, Matthias
    Holzapfel, Konstantin
    Ganter, Carl
    Epple, Kathrin
    Metz, Stephan
    Geinitz, Hans
    Kuebler, Hubert
    Gaa, Jochen
    Rummeny, Ernst J.
    Beer, Ambros J.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (05) : 1160 - 1170
  • [9] Essig M, 2000, J MAGN RESON IMAGING, V11, P506, DOI 10.1002/(SICI)1522-2586(200005)11:5<506::AID-JMRI6>3.0.CO
  • [10] 2-D