Whole-body MRI for metastatic cancer detection using T2-weighted imaging with fat and fluid suppression

被引:9
作者
Wang, Xinzeng [1 ]
Pirasteh, Ali [1 ]
Brugarolas, James [2 ,3 ]
Rofsky, Neil M. [1 ,4 ]
Lenkinski, Robert E. [1 ,4 ]
Pedrosa, Ivan [1 ,2 ,4 ]
Madhuranthakam, Ananth J. [1 ,4 ]
机构
[1] Univ Texas Southwestern Med Ctr Dallas, Dept Radiol, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
[2] Univ Texas Southwestern Med Ctr Dallas, Simmons Comprehens Canc Ctr, Kidney Canc Program, Dallas, TX 75390 USA
[3] Univ Texas Southwestern Med Ctr Dallas, Dept Internal Med, Dallas, TX USA
[4] UT Southwestern Med Ctr, Adv Imaging Res Ctr, Dallas, TX USA
基金
美国国家卫生研究院;
关键词
fat suppression; fluid suppression; metastatic cancer; whole-body imaging; FAST SPIN-ECHO; BONE-SCINTIGRAPHY; RELAXATION-TIMES; FDG-PET/CT; 3.0; T; DWI; TUMORS; CONSPICUOUSNESS; EXPERIENCE; CARCINOMA;
D O I
10.1002/mrm.27117
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a whole-body MRI technique at 3T with improved lesion conspicuity for metastatic cancer detection using fast, high-resolution and high SNR T-2-weighted (T2W) imaging with simultaneous fat and fluid suppression. Theory and Methods: The proposed dual-echo T-2-weighted acquisition for enhanced conspicuity of tumors (DETECT) acquires 4 images, in-phase (IP) and out-of-phase (OP) at a short and a long TE using single-shot turbo spin echo. The IP/OP images at the short and long TEs are reconstructed using the standard Dixon and shared-field-map Dixon reconstruction respectively, for robust fat-water separation. An adaptive complex subtraction between the 2 TE water-only images achieves fluid attenuation. DETECT imaging was optimized and evaluated in whole-body imaging of 5 healthy volunteers, and compared against diffusion-weighted imaging with background suppression (DWIBS) in 5 patients with known metastatic renal cell carcinoma. Results: Robust fat-water separation and fluid attenuation were achieved using the shared-field-map Dixon reconstruction and adaptive complex subtraction, respectively. DETECT imaging technique generated co-registered T2W images with and without fat suppression, heavily T2W, and fat and fluid suppressed T2W whole-body images in < 7 min. Compared to DWIBS acquired in 17 min, the DETECT imaging achieved better detection and localization of lesions in patients with metastatic cancer. Conclusion: DETECT imaging technique generates T2W images with high resolution, high SNR, minimal geometric distortions, and provides good lesion conspicuity with robust fat and fluid suppression in < 7 min for whole-body imaging, demonstrating efficient and reliable metastatic cancer detection at 3T.
引用
收藏
页码:1402 / 1415
页数:14
相关论文
共 43 条
[1]   Accuracy of whole-body dual-modality fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography and computed tomography (FDG-PET/CT) for tumor staging in solid tumors: Comparison with CT and PET [J].
Antoch, G ;
Saoudi, N ;
Kuehl, H ;
Dahmen, G ;
Mueller, SP ;
Beyer, T ;
Bockisch, A ;
Debatin, JF ;
Freudenberg, LS .
JOURNAL OF CLINICAL ONCOLOGY, 2004, 22 (21) :4357-4368
[2]   MR Fingerprinting of Adult Brain Tumors: Initial Experience [J].
Badve, C. ;
Yu, A. ;
Dastmalchian, S. ;
Rogers, M. ;
Ma, D. ;
Jiang, Y. ;
Margevicius, S. ;
Pahwa, S. ;
Lu, Z. ;
Schluchter, M. ;
Sunshine, J. ;
Griswold, M. ;
Sloan, A. ;
Gulani, V. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (03) :492-499
[3]   Two-point Dixon Method With Flexible Echo Times [J].
Berglund, Johan ;
Ahlstroem, Hakan ;
Johansson, Lars ;
Kullberg, Joel .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) :994-1004
[4]   Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo [J].
Busse, Reed F. ;
Brau, Anja C. S. ;
Vu, Anthony ;
Michelich, Charles R. ;
Bayram, Ersin ;
Kijowski, Richard ;
Reeder, Scott B. ;
Rowley, Howard A. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) :640-649
[5]   MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results [J].
de Bazelaire, CMJ ;
Duhamel, GD ;
Rofsky, NM ;
Alsop, DC .
RADIOLOGY, 2004, 230 (03) :652-659
[6]   Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System [J].
Del Grande, Filippo ;
Santini, Francesco ;
Herzka, Daniel A. ;
Aro, Michael R. ;
Dean, Cooper W. ;
Gold, Garry E. ;
Carrino, John A. .
RADIOGRAPHICS, 2014, 34 (01) :217-233
[7]   Dual-Echo Dixon Imaging with Flexible Choice of Echo Times [J].
Eggers, Holger ;
Brendel, Bernhard ;
Duijndam, Adri ;
Herigault, Gwenael .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (01) :96-107
[8]   Whole-Body MRI Including Diffusion-Weighted Imaging (DWI) for Patients With Recurring Prostate Cancer: Technical Feasibility and Assessment of Lesion Conspicuity in DWI [J].
Eiber, Matthias ;
Holzapfel, Konstantin ;
Ganter, Carl ;
Epple, Kathrin ;
Metz, Stephan ;
Geinitz, Hans ;
Kuebler, Hubert ;
Gaa, Jochen ;
Rummeny, Ernst J. ;
Beer, Ambros J. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (05) :1160-1170
[9]  
Essig M, 2000, J MAGN RESON IMAGING, V11, P506, DOI 10.1002/(SICI)1522-2586(200005)11:5<506::AID-JMRI6>3.0.CO
[10]  
2-D