Audible Noise Characters Analysis of 220kV Xiangtang Transmission Line

被引:0
|
作者
Zhao, Can [1 ]
Zhao, Xinmin [2 ]
Wu, Fayuan [3 ]
Xu, Chenyong [1 ]
机构
[1] State Grid Jiangsu Elect Power Co Ltd, Suzhou Power Supply Co, Suzhou 215004, Peoples R China
[2] State Grid Jiangsu Elect Power Co Ltd, Ganxi Power Supply Co, Xinyu 338000, Peoples R China
[3] State Grid Jiangsu Elect Power Co Ltd, Elect Power Res Inst, Nanchang 330096, Jiangxi, Peoples R China
关键词
D O I
10.1088/1755-1315/295/4/042109
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In order to know the corona audible noise characters of the 220kV transmission line and its influences on nearby residents' life, we measured the corona discharge UV-light, the environmental noise and sound energy of the transmission line respectively. The study results showed that the corona discharge occurred at the transmission line. The audible noise sound level on the roof was 46.2dB(A) at night, that was slightly beyond the limit value of the first zone of Sound Environment Quality Standard. At night, the transmission line audible noise like 'SiSi' was so obvious that disturbs residents. The sound energy analysis results showed that the transmission line audible noise energy focused on the frequency range below 200Hz. The directivity study of sound intensity showed that the highest sound energy happened at 100 Hz in the direction from the transmission line to the top floor of the residents' house, in which explains that the transmission line noise, slightly beyond the limit, is obvious.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Failure Analysis on Strain Clamp on 220kV Transmission Line
    Xu, XueXia
    Feng, YanTing
    Ke, Hao
    Niu, XiaoGuang
    Ouyang, Jie
    ADVANCES IN MATERIALS AND MATERIALS PROCESSING, PTS 1-3, 2013, 652-654 : 1405 - 1409
  • [2] The Analysis of Overvoltage on 220kV Transmission Line in Single-phase Reclosing
    Cheng, Qiang
    Wang, Dong-qing
    Fan, Li-qin
    Liu, Xin-yuan
    2016 INTERNATIONAL CONFERENCE ON POWER, ENERGY ENGINEERING AND MANAGEMENT (PEEM 2016), 2016, : 25 - 31
  • [3] Back Flashover Protection Performance Analysis of 220kV Double Circuit Transmission Line
    Wu Shuwen
    Sun Wenxin
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [4] STUDY ON FRACTURE CAUSE OF PORCELAIN INSULATOR OF 220KV TRANSMISSION LINE
    Shen, Hao
    Jia, Ran
    Liu, Rong
    Liu, Hui
    Shen, Qinghe
    IET Conference Proceedings, 2022, 2022 (05): : 1284 - 1289
  • [5] AC Transmission Line Fault Current Analysis in 220kV AC/DC Hybrid System
    Zhao, Wenyuan
    Shi, Shenxing
    Wang, Zhenghao
    Dong, Xinzhou
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 1105 - 1109
  • [6] Computation of Audible Noise from a 1200 kV UHV Power Transmission Line
    Kumar, K. Bharath
    Thomas, M. Joy
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (02) : 974 - 978
  • [7] Influence of the lightning arrester position on protection of the 220KV Overhead transmission line
    Boumous, Samira
    Boumous, Zouhir
    Latreche, Samia
    Nouri, Hamou
    PRZEGLAD ELEKTROTECHNICZNY, 2023, 99 (05): : 13 - 17
  • [8] Computation of Lightning Protection System for 220kV Transmission Line Inside Substation
    Ibrahim, Mohammed Abdaldaim
    Li, Lin
    Wang, Ping
    CONFERENCE PROCEEDINGS OF 2019 5TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND ROBOTICS (ICCAR), 2019, : 29 - 34
  • [9] Electric field analysis and structure design of the box of bird guard used in 220kV transmission line
    Kuang, Yanjun
    Li, Yanglin
    Deng, Yongqing
    Huang, Daochun
    Qiu, Zhibin
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2860 - 2863
  • [10] Spectrum characters of the audible noise from ±500 kV Ge-Nan and Yi-Hua transmission line and affecting factors
    Lu, Yao
    Qi, Xiao-Man
    Zhang, Guang-Zhou
    Wan, Bao-Quan
    Zhang, Ze-Ping
    Ni, Yuan
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (11): : 2754 - 2759