Protein microarrays: Reduced autofluorescence and improved LOD

被引:21
作者
Walter, Johanna-Gabriela [1 ]
Stahl, Frank [1 ]
Reck, Michael [1 ]
Praulich, Inka [1 ]
Nataf, Yakir
Hollas, Markus [2 ]
Pflanz, Karl [2 ]
Melzner, Dieter [2 ]
Shoham, Yuval [3 ]
Scheper, Thomas [1 ]
机构
[1] Leibniz Univ Hannover, Inst Tech Chem, D-30167 Hannover, Germany
[2] Sartorius Stedim Biotech, Gottingen, Germany
[3] Technion Israel Inst Technol, Dept Biotechnol & Food Engn, Technion, Haifa, Israel
来源
ENGINEERING IN LIFE SCIENCES | 2010年 / 10卷 / 02期
关键词
Background fluorescence; Limit of detection; LOD; Nitrocellulose; Protein microarray; ANTIBODY MICROARRAYS; HIGH-THROUGHPUT; SURFACE; PHASE; DNA;
D O I
10.1002/elsc.200900078
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In protein microarray performance, the choice of an appropriate surface is a crucial factor. Three-dimensional substrates like nitrocellulose are known to have higher binding capacities than planar surfaces. Furthermore, they can enable the immobilization of proteins in a functional manner. One disadvantage of today's nitrocellulose-based microarrays is the high background fluorescence, which can interfere with the detection of low-abundance proteins. We have developed an innovative black nitrocellulose membrane-based protein microarray that exhibits low autofluorescence in combination with increased sensitivity and improved LOD (limit of detection). The applicability of the novel material was demonstrated with main focus on reversed-phase microarray experiments. In comparison to various commercially available microarrays, a higher sensitivity in regard to the spotted protein was achieved. In contrast to other porous nitrocellulose-based microarrays, the black nitrocellulose provides a significant lower autofluorescence and background intensity.
引用
收藏
页码:103 / 108
页数:6
相关论文
共 37 条
[1]   Development of reverse phase protein microarrays for the validation of clusterin, a mid-abundant blood biomarker [J].
Aguilar-Mahecha, Adriana ;
Cantin, Christiane ;
O'Connor-McCourt, Maureen ;
Nantel, Andre ;
Basik, Mark .
PROTEOME SCIENCE, 2009, 7
[2]   The human plasma proteome - History, character, and diagnostic prospects [J].
Anderson, NL ;
Anderson, NG .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (11) :845-867
[3]   Next generation of protein microarray support materials:: Evaluation for protein and antibody microarray applications [J].
Angenendt, P ;
Glökler, J ;
Sobek, J ;
Lehrach, H ;
Cahill, DJ .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1009 (1-2) :97-104
[4]   RELATION BETWEEN MATERNAL AGE AND SERUM CONCENTRATION OF IGG ANTIBODY TO TYPE-III GROUP-B STREPTOCOCCI [J].
ANTHONY, BF ;
CONCEPCION, IE ;
CONCEPCION, NF ;
VADHEIM, CM ;
TIWARI, J .
JOURNAL OF INFECTIOUS DISEASES, 1994, 170 (03) :717-720
[5]   Molecular signatures for diagnosis of infection: application of microarray technology [J].
Campbell, CJ ;
Ghazal, P .
JOURNAL OF APPLIED MICROBIOLOGY, 2004, 96 (01) :18-23
[6]   Affinity-capture reagents for protein arrays [J].
Elia, G ;
Silacci, M ;
Scheurer, S ;
Scheuermann, J ;
Neri, D .
TRENDS IN BIOTECHNOLOGY, 2002, 20 (12) :S19-S22
[7]   Protein microarrays: Molecular profiling technologies for clinical specimens [J].
Espina, V ;
Mehta, AI ;
Winters, ME ;
Calvert, V ;
Wulfkuhle, J ;
Petricoin, EF ;
Liotta, LA .
PROTEOMICS, 2003, 3 (11) :2091-2100
[8]  
FISLER R, 2004, AM BIOTECHNOL LAB, P23
[9]   Protein and antibody microarray technology [J].
Glökler, J ;
Angenendt, P .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 797 (1-2) :229-240
[10]  
Grainger David W., 2007, V381, P37