Low-frequency electrical dosimetry: research agenda of the IEEE International Committee on Electromagnetic Safety

被引:65
作者
Reilly, J. Patrick [1 ]
Hirata, Akimasa [2 ]
机构
[1] Metatec Associates, 12516 Davan Dr, Silver Spring, MD 20904 USA
[2] Nagoya Inst Technol, Dept Comp Sci & Engn, Showa Ku, Gokiso Cho, Nagoya, Aichi 4668555, Japan
关键词
low-frequency field; electrostimulation; international safety standards/guidelines; research agenda; INDUCED CURRENT DENSITIES; PERIPHERAL-NERVE STIMULATION; SKELETAL-MUSCLE ANISOTROPY; MAGNETIC-FIELDS; COMPUTATIONAL DOSIMETRY; EXPOSURE ASSESSMENT; ORGAN DOSIMETRY; HUMAN MODELS; ELECTROSTIMULATION; CONDUCTIVITY;
D O I
10.1088/0031-9155/61/12/R138
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This article treats unsettled issues in the use of numerical models of electrical dosimetry as applied to international limits on human exposure to low-frequency (typically < 100 kHz) electromagnetic fields and contact current. The perspective in this publication is that of Subcommittee 6 of IEEE-ICES (International Committee on Electromagnetic Safety) Technical Committee 95. The paper discusses 25 issues needing attention, fitting into three general categories: induction models; electrostimulation models; and human exposure limits. Of these, 9 were voted as 'high priority' by members of Subcommittee 6. The list is presented as a research agenda for refinements in numerical modeling with applications to human exposure limits. It is likely that such issues are also important in medical and electrical product safety design applications.
引用
收藏
页码:R138 / R149
页数:12
相关论文
共 56 条
[1]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[2]  
[Anonymous], 2005, IEC62233
[3]  
[Anonymous], 2007, IEC62311
[4]  
[Anonymous], 2006, Standard C95.1-2005, P1, DOI [10.1109/IEEESTD.2006.99501, DOI 10.1109/IEEESTD.2006.99501]
[5]  
[Anonymous], 2002, IEEEC956
[6]  
Chan D D, 2007, BIOMEDICAL ENG RECEN, P92
[7]   Computational dosimetry for grounded and ungrounded human models due to contact current [J].
Chan, Kwok Hung ;
Hattori, Junya ;
Laakso, Ilkka ;
Hirata, Akimasa ;
Taki, Masao .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (15) :5153-5172
[8]   Analysis of human brain exposure to low-frequency magnetic fields: A numerical assessment of spatially averaged electric fields and exposure limits [J].
Chen, Xi-Lin ;
Benkler, Stefan ;
Chavannes, Nicholas ;
De Santis, Valerio ;
Bakker, Jurriaan ;
van Rhoon, Gerard ;
Mosig, Juan ;
Kuster, Niels .
BIOELECTROMAGNETICS, 2013, 34 (05) :375-384
[9]  
Dawson T. W., 2001, Applied Computational Electromagnetics Society Journal, V16, P162
[10]   Effects of skeletal muscle anisotropy on human organ dosimetry under 60 Hz uniform magnetic field exposure [J].
Dawson, TW ;
Stuchly, MA .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05) :1059-1074