Exergoeconomic and environmental analyses of CO2/NH3 cascade refrigeration systems equipped with different types of flash tank intercoolers

被引:196
|
作者
Mosaffa, A. H. [1 ]
Farshi, L. Garousi [2 ]
Ferreira, C. A. Infante [3 ]
Rosen, M. A. [4 ]
机构
[1] Azarbaijan Shahid Madani Univ, Dept Mech Engn, Tabriz, Iran
[2] Univ Tabriz, Fac Mech Engn, Tabriz, Iran
[3] Delft Univ Technol, Dept Proc & Energy, NL-2628 CB Delft, Netherlands
[4] Univ Ontario Inst Technol, Fac Engn & Appl Sci, Oshawa, ON L1H 7K4, Canada
关键词
Cascade refrigeration system; CO2/NH3; Exergoeconomic analysis; Environmental analysis; Optimization; Flash tank; HEAT-PUMP SYSTEM; THERMODYNAMIC ANALYSIS; MULTIOBJECTIVE OPTIMIZATION; ENERGY; CO2; TEMPERATURE; CONDENSER; DESIGN; COSTS;
D O I
10.1016/j.enconman.2016.03.053
中图分类号
O414.1 [热力学];
学科分类号
摘要
Exergoeconomic and environmental analyses are presented for two CO2/NH3 cascade refrigeration systems equipped with (1) two flash tanks and (2) a flash tank along with a flash intercooler with indirect subcooler. A comparative study is performed for the proposed systems, and optimal values of operating parameters of the system are determined that maximize the coefficient of performance (COP) and exergy efficiency and minimize the total annual cost. The operating parameters considered include condensing temperatures of NH3 in the condenser and CO3 in the cascade heat exchanger, the evaporating temperature of CO2 in the evaporator, the temperature difference in the cascade heat exchanger, the intermediate pressure of the flash tank in the CO2 low-temperature circuit, the mass flow rate ratio in the flash intercooler and the degree of superheating of the CO2 at the evaporator outlet. The total annual cost includes the capital, operating and maintenance costs and the penalty cost of GHG emission. The results show that, the total annual cost rate for system 1 is 11.2% and 11.9% lower than that for system 2 referring to thermodynamic and economic optimizations, respectively. For thermodynamic and cost optimal design condition the COP and exergy efficiency of both systems are almost the same. Finally, in order to obtain the best balance between exergy destruction cost and capital cost, the exergoeconomic factor is defined for each component of proposed systems, for cases in which the system operates at the best performance conditions. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:442 / 453
页数:12
相关论文
共 50 条
  • [1] Thermoeconomic optimization and exergy analysis of CO2/NH3 cascade refrigeration systems
    Rezayan, Omid
    Behbahaninia, Ali
    ENERGY, 2011, 36 (02) : 888 - 895
  • [2] Exergetic, economic and environmental (3E) analyses, and multiobjective optimization of a CO2/NH3 cascade refrigeration system
    Aminyavari, Mehdi
    Najafi, Behzad
    Shirazi, Alec
    Rinaldi, Fabio
    APPLIED THERMAL ENGINEERING, 2014, 65 (1-2) : 42 - 50
  • [3] PERFORMANCE OF NH3/CO2 CASCADE REFRIGERATION SYSTEM WITH EJECTOR
    Pratihar, A. K.
    Joshi, Rachit
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 194 - 201
  • [4] Thermodynamic analysis of a NH3/CO2 cascade refrigeration system
    Wang, Xiao-Fei
    Zhang, Wei-Min
    Lu, Yun-Zhuang
    Yan, Gang
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2015, 36 (10): : 2092 - 2096
  • [5] The Entropy Analysis on NH3/CO2 Cascade Refrigeration Cycle
    Xie, Yingbai
    Cui, Kuikui
    Zong, Luxiang
    Wang, Zhichao
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2010, VOL 5, PTS A AND B, 2012, : 823 - 828
  • [6] Analysis of thermodynamic performance in NH3/CO2 Cascade refrigeration system
    Duan Rui
    Cui Guomin
    Zhu Qunzhi
    ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 1484 - +
  • [7] PURE NH3 AND CO2 HEAT TRANSFER AND PRESSURE DROP IN HORIZONTAL SMOOTH TUBES FOR NH3 TWO-STAGE AND NH3/CO2 CASCADE REFRIGERATION SYSTEMS: A REVIEW
    Park, C. Y.
    Hrnjak, P. S.
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2010, 18 (02) : 85 - 100
  • [8] Thermodynamic analysis of optimal condensing temperature of cascade-condenser in CO2/NH3 cascade refrigeration systems
    Lee, Tzong-Shing
    Liu, Cheng-Hao
    Chen, Tung-Wei
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (07): : 1100 - 1108
  • [9] Advanced exergy analysis of NH3/CO2 cascade refrigeration system with ejector
    Chi, Weikai
    Yang, Qichao
    Chen, Xiaonan
    Li, Liansheng
    Liu, Guangbin
    Zhao, Yuanyang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 145 : 185 - 195
  • [10] Thermodynamic investigation and optimization of novel ejector-expansion CO2/NH3 cascade refrigeration cycles (novel CO2/NH3 cycle)
    Dokandari, Damoon Aghazadeh
    Hagh, Alireza Setayesh
    Mahmoudi, S. M. S.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 46 : 26 - 36