Oxidative status in different settings and with different methodological approaches compared by Receiver Operating Characteristic curve analysis

被引:14
作者
Cighetti, Giuliana [1 ]
Bamonti, Fabrizia [2 ,3 ]
Aman, Caroline S. [1 ]
Gregori, Dario [4 ]
De Giuseppe, Rachele [2 ,3 ]
Novembrino, Cristina [5 ]
de Liso, Federica [5 ]
Maiavacca, Rita [5 ]
Paroni, Rita [6 ]
机构
[1] Univ Milan, Dipartimento Sci Biomed & Clin L Sacco, I-20132 Milan, Italy
[2] Univ Milan, Dipartimento Sci Biomed Chirurg & Odontoiatriche, I-20132 Milan, Italy
[3] Fdn IRCCS Ca Granda Osped Maggiore Policlin, UO Ematol & CTMO, Milan, Italy
[4] Univ Padua, Dipartimento Sci Cardiol Toraciche & Vasc, Unita Biostat Epidemiol & Salute Pubbl, Padua, Italy
[5] Fdn IRCCS Ca Granda Osped Maggiore Policlin, Lab Chim Clin & Microbiol, Milan, Italy
[6] Univ Milan, Dipartimento Sci Salute, I-20132 Milan, Italy
关键词
Antioxidant status; Isotope-dilution-gas chromatography-mass; spectrometry; Malondialdehyde; Method comparison; Oxidative stress; ROC curve analysis; TOTAL ANTIOXIDANT CAPACITY; MALONDIALDEHYDE DETECTION; METHYL MALONDIALDEHYDE; INTERNAL STANDARD; STRESS; VALIDATION; BIOMARKERS; MARKERS; INJURY; SERUM;
D O I
10.1016/j.clinbiochem.2014.09.025
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: To test the performance of different analytical approaches in highlighting the occurrence of deregulated redox status in various physio-pathological situations. Design and methods: 35 light and 61 heavy smokers, 19 chronic renal failure, 59 kidney transplanted patients, and 87 healthy controls were retrospectively considered for the study. Serum oxidative stress and antioxidant status, assessed by spectrophotometric Reactive Oxygen Metabolites (d-ROMs) and Total Antioxidant Capacity (TAC) tests, respectively, were compared with plasma free (F-MDA) and total (T-MDA) malondialdehyde, both quantified by isotope-dilution-gas chromatography-mass spectrometry (ID-GC-MS). Sensitivity, specificity and cut-off points of T-MDA, F-MDA, d-ROMs and TAC were evaluated by both Receiver Operating Characteristic (ROC) analyses and area under the ROC curve (AUC). Results: Only T-MDA assay showed a clear absence of oxidative stress in controls and significant increase in all patients (AUC 1.00, sensitivity and specificity 100%). Accuracy was good for d-ROMs (AUC 0.87, sensitivity 72.8%, specificity 100%) and F-MDA (AUC 0.82, sensitivity 74.7%, specificity 83.9%), but not high enough for TAC to show in patients impaired antioxidant defense (AUC 0.66, sensitivity 52.0%, specificity 92.9%). Conclusions: This study reveals T-MDA as the best marker to detect oxidative stress, shows the ability of d-ROMs to identify modified oxidative status particularly in the presence of high damages, and evidences the poor TAC performance. d-ROMs and TAC assays could be useful for routine purposes; however, for an accurate clinical data evaluation, their comparison versus a "gold standard method" is required. (C) 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:73 / 78
页数:6
相关论文
共 39 条
[1]   Guidance on the scientific requirements for health claims related to antioxidants, oxidative damage and cardiovascular health [J].
Agostoni, Carlo ;
Bresson, Jean-Louis ;
Fairweather-Tait, Susan ;
Flynn, Albert ;
Golly, Ines ;
Korhonen, Hannu ;
Lagiou, Pagona ;
Lovik, Martinus ;
Marchelli, Rosangela ;
Martin, Ambroise ;
Moseley, Bevan ;
Neuhauser-Berthold, Monika ;
Przyrembel, Hildegard ;
Salminen, Seppo ;
Sanz, Yolanda ;
Strain, Sean ;
Strobel, Stephan ;
Tetens, Inge ;
Tome, Daniel ;
van Loveren, Hendrik ;
Verhagen, Hans .
EFSA JOURNAL, 2011, 9 (12)
[2]  
[Anonymous], HOSP PHYS
[3]   Increased free malondialdehyde concentrations in smokers normalise with a mixed fruit and vegetable juice concentrate: a pilot study [J].
Bamonti, F ;
Novembrino, C ;
Ippolito, S ;
Soresi, E ;
Ciani, A ;
Lonati, S ;
Scurati-Manzoni, E ;
Cighetti, G .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (04) :391-395
[4]   Determination of serum holotranscobalamin concentrations with the AxSYM active B12 assay: cut-off point evaluation in the clinical laboratory [J].
Bamonti, Fabrizia ;
Moscato, Giovanna Antonella ;
Novembrino, Cristina ;
Gregori, Dario ;
Novi, Claudia ;
De Giuseppe, Rachele ;
Galli, Claudio ;
Uva, Valentina ;
Lonati, Silvia ;
Maiavacca, Rita .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (02) :249-253
[5]   Plasma oxidative stress biomarkers, nitric oxide and heat shock protein 70 in trained elite soccer players [J].
Banfi, G ;
Malavazos, A ;
Iorio, E ;
Dolci, A ;
Doneda, L ;
Verna, R ;
Corsi, MM .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2006, 96 (05) :483-486
[6]   Oxidative stress in kidney transplant patients [J].
Campise, M ;
Bamonti, F ;
Novembrino, C ;
Ippolito, S ;
Tarantino, A ;
Cornelli, U ;
Lonati, S ;
Cesana, BM ;
Ponticelli, C .
TRANSPLANTATION, 2003, 76 (10) :1474-1478
[7]  
Cesarone MR, 1999, INT ANGIOL, V18, P127
[8]   Evaluation of oxidative stress in serum of critically ill patients by a commercial assay and gas chromatography-mass spectrometry [J].
Cighetti, G ;
Paroni, R ;
Marzorati, S ;
Borotto, E ;
Giudici, R ;
Magnanini, G ;
Iapichino, G .
CLINICAL CHEMISTRY, 2005, 51 (08) :1515-1517
[9]  
Cighetti G, 2002, CLIN CHEM, V48, P2266
[10]   Free and total malondialdehyde assessment in biological matrices by gas chromatography mass spectrometry: What is needed for an accurate detection [J].
Cighetti, G ;
Debiasi, S ;
Paroni, R ;
Allevi, P .
ANALYTICAL BIOCHEMISTRY, 1999, 266 (02) :222-229