Microbend Fiber Optic Sensor for Perioperative Pediatric Vital Signs

被引:2
作者
Chen, Zhihao [1 ]
Hee, Hwan Ing [2 ]
Ng, Soon Huat [3 ]
Teo, Ju Teng [3 ]
Yang, Xiufeng [3 ]
Wang, Dier [4 ]
机构
[1] Quanzhou Normal Univ, Donghai 362000, Quanzhou, Peoples R China
[2] KK Womens & Childrens Hosp, 100 Bukit Timah Rd, Singapore 229899, Singapore
[3] Inst Infocomm Res, 1 Fusionopolis Way, Singapore 138632, Singapore
[4] Nanyang Technol Univ, 50 Nanyang Ave, Singapore 639798, Singapore
来源
OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XVII | 2017年 / 10058卷
关键词
Vital signs monitoring; Pediatric patient monitoring; Fiber optic sensor; RESPIRATION; HEARTBEAT;
D O I
10.1117/12.2250498
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We have demonstrated a highly sensitive microbend fiber optic sensor for perioperative pediatric vital signs monitoring that is free from direct contact with skin, cableless, electromagnetic interference free and low cost. The feasibility of our device was studied on infants undergoing surgery and 10 participants ranging from one month to 12 months were enrolled. The sensor was placed under a barrier sheet on the operating table. All patients received standard intraoperative monitoring. The results showed good agreement in heart rate and respiratory rate between our device and the standard physiological monitoring when signals are clean.
引用
收藏
页数:8
相关论文
共 12 条
[1]  
Chen Z., 2014, J BIOMEDICAL OPTICS, V19
[2]  
Chung GS, 2010, IEEE ENG MED BIO, P2459, DOI 10.1109/IEMBS.2010.5626544
[3]   Fiber Bragg grating-based sensor for monitoring respiration and heart activity during magnetic resonance imaging examinations [J].
Dziuda, Lukasz ;
Skibniewski, Franciszek W. ;
Krej, Mariusz ;
Baran, Paulina M. .
JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (05)
[4]   Monitoring Respiration and Cardiac Activity Using Fiber Bragg Grating-Based Sensor [J].
Dziuda, Lukasz ;
Skibniewski, Franciszek Wojciech ;
Krej, Mariusz ;
Lewandowski, Jaroslaw .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (07) :1934-1942
[5]   Heart rate detection from an electronic weighing scale [J].
Gonzalez-Landaeta, R. ;
Casas, O. ;
Pallas-Areny, R. .
PHYSIOLOGICAL MEASUREMENT, 2008, 29 (08) :979-988
[6]   Optical fiber sensors embedded into medical textiles for healthcare monitoring [J].
Grillet, Augustin ;
Kinet, Damien ;
Witt, Jens ;
Schukar, Marcus ;
Krebber, Katerina ;
Pirotte, Fabrice ;
Depre, Annick .
IEEE SENSORS JOURNAL, 2008, 8 (7-8) :1215-1222
[7]  
KOIVISTOINEN T, 2004, IEEE P EMBC 04, P2026
[8]   Intensity-Modulated Microbend Fiber Optic Sensor for Respiratory Monitoring and Gating During MRI [J].
Lau, Doreen ;
Chen, Zhihao ;
Teo, Ju Teng ;
Ng, Soon Huat ;
Rumpel, Helmut ;
Lian, Yong ;
Yang, Hui ;
Kei, Pin Lin .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (09) :2655-2662
[9]   Respiration and body movement analysis during sleep in bed using hetero-core fiber optic pressure sensors without constraint to human activity [J].
Nishyama, Michiko ;
Miyamoto, Mitsuo ;
Watanabe, Kazuhiro .
JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (01)
[10]   A 'smart' bed for non-intrusive monitoring of patient physiological factors [J].
Spillman, WB ;
Mayer, M ;
Bennett, J ;
Gong, J ;
Meissner, KE ;
Davis, B ;
Claus, RO ;
Muelenaer, AA ;
Xu, X .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (08) :1614-1620