Study and Analysis of HTLS Conductors for Increasing the Thermal Loading of 220 kV Transmission Line

被引:1
|
作者
Kachhadiya, Akshit [1 ]
Sheth, Chetan [1 ]
Gupta, Vinod [2 ]
Darji, Krunal [2 ]
机构
[1] GH Patel Coll Engn & Technol, Vallabh Vidhyanagar 388120, India
[2] Elect Res & Dev Assoc, Vadodara 390010, India
关键词
High temperature low sag conductors; Overhead lines; Re-conductoring; Ampacity; Thermal loading limit;
D O I
10.1007/978-981-15-0206-4_20
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the present scenario, demand of electricity is increasing drastically across the country in order to revolutionize development in industrial, agriculture and commercial section. As a consequence, the amount of power transfer capacity has to be enhanced on overhead transmission lines. However, the existing lines are gaining their utmost critical limits of ampacity and sag. This complication has become very predominant to obtain reliable, secure and economic operation of power system. In India, ACSR conductors are generally used in overhead transmission lines for transmission of power. The higher power transferability in existing lines, reduction in losses and optimization of Right of Way of electrical network are the requirement of the today's power system network. New generation high-performance conductors would help in electric power delivery system for efficient transmission of energy by way of enhancement of power flow per unit of Right of Way and reduction in losses under normal as well as under critical conditions can help in resolving the issues like growing congestion in existing corridors of transmission/distribution network and Right of Way problems. Low-resistant conductor-AL59 alloy conductors and high temperature low sag (HTLS) conductors can be used for re-conductoring of existing lines to mitigate the overloading issues. Several HTLS conductors like STACIR, ACSS, ACCC, TACSR, etc., are available in the market. Selection of HTLS conductor is also an important parameter for re-conductoring of any transmission line. This paper discusses the issues of overloading of transmission line and mitigation by re-conductoring through HTLS conductors. A case study is described by re-conductoring of several HTLS and AL59 conductors, and optimum solution is proposed for avoiding overloading of transmission line.
引用
收藏
页码:229 / 238
页数:10
相关论文
共 50 条
  • [1] Reconductoring using HTLS conductors. Case study for a 220 kV Double Circuit Transmission LINE in Romania
    Mateescu, E.
    Marginean, D.
    Florea, G.
    Gal, St. I. A.
    Matea, C.
    2011 IEEE PES 12TH INTERNATIONAL CONFERENCE ON TRANSMISSION AND DISTRIBUTION CONSTRUCTION, OPERATION AND LIVE-LINE MAINTENANCE (ESMO), 2011,
  • [2] Analysis on subconductors conglutination phenomena of 220 kV transmission line
    School of Electrical Engineering, Wuhan University, Wuhan 430072, China
    不详
    不详
    Gaodianya Jishu, 2006, 11 (61-63):
  • [3] A STUDY OF GALLOPING CONDUCTORS ON A 230-KV TRANSMISSION-LINE
    RICHARDSON, AS
    ELECTRIC POWER SYSTEMS RESEARCH, 1991, 21 (01) : 43 - 55
  • [4] Failure Analysis on Strain Clamp on 220kV Transmission Line
    Xu, XueXia
    Feng, YanTing
    Ke, Hao
    Niu, XiaoGuang
    Ouyang, Jie
    ADVANCES IN MATERIALS AND MATERIALS PROCESSING, PTS 1-3, 2013, 652-654 : 1405 - 1409
  • [5] Study of the impact of 220 kV SISFCL on the distance protection for transmission line
    Luo, Yinghong
    Shi, Tongtong
    Huang, Linke
    ARCHIVES OF ELECTRICAL ENGINEERING, 2018, 67 (01) : 151 - 163
  • [6] Performance Comparison of Using ACSR and HTLS Conductors for Current Uprating of 230-kV Overhead Transmission Lines
    Nuchprayoon, Somboon
    Chaichana, Artitaya
    2018 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2018 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2018,
  • [7] Switching transients in overhead transmission line 220 kV
    Vasileva, Margreta
    Stanchev, Danail
    7TH INTERNATIONAL CONFERENCE ON ENERGY EFFICIENCY AND AGRICULTURAL ENGINEERING (EE&AE), 2020,
  • [8] Audible Noise Characters Analysis of 220kV Xiangtang Transmission Line
    Zhao, Can
    Zhao, Xinmin
    Wu, Fayuan
    Xu, Chenyong
    2019 5TH INTERNATIONAL CONFERENCE ON ENERGY MATERIALS AND ENVIRONMENT ENGINEERING, 2019, 295
  • [9] STUDY ON FRACTURE CAUSE OF PORCELAIN INSULATOR OF 220KV TRANSMISSION LINE
    Shen, Hao
    Jia, Ran
    Liu, Rong
    Liu, Hui
    Shen, Qinghe
    IET Conference Proceedings, 2022, 2022 (05): : 1284 - 1289
  • [10] The Analysis of Overvoltage on 220kV Transmission Line in Single-phase Reclosing
    Cheng, Qiang
    Wang, Dong-qing
    Fan, Li-qin
    Liu, Xin-yuan
    2016 INTERNATIONAL CONFERENCE ON POWER, ENERGY ENGINEERING AND MANAGEMENT (PEEM 2016), 2016, : 25 - 31