A deliberately restricted laryngeal view with the GlideScopeA® video laryngoscope is associated with faster and easier tracheal intubation when compared with a full glottic view: a randomized clinical trial

被引:0
作者
Gu, Yuqi [1 ]
Robert, Joshua [1 ]
Kovacs, George [1 ]
Milne, Andrew D. [1 ]
Morris, Ian [1 ]
Hung, Orlando [1 ]
MacQuarrie, Kirk [1 ]
Mackinnon, Sean [2 ]
Law, J. Adam [1 ]
机构
[1] Dalhousie Univ, QEII Hlth Sci Ctr, Dept Anesthesia Pain Management & Perioperat Med, Halifax Infirm Site,1796 Summer St, Halifax, NS B3H 3A7, Canada
[2] Dalhousie Univ, Dept Psychol & Neurosci, 1355 Oxford St,POB 15000, Halifax, NS B3H 4R2, Canada
来源
CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 2016年 / 63卷 / 08期
关键词
DIFFICULT AIRWAY; VIDEOLARYNGOSCOPE; MANAGEMENT; PATIENT; RECOMMENDATIONS; VISUALIZATION; ANESTHETISTS;
D O I
10.1007/s12630-016-0654-6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
During video laryngoscopy (VL) with angulated or hyper-curved blades, it is sometimes difficult to complete tracheal intubation despite a full view of the larynx. When using indirect VL, it has been suggested that it may be preferable to obtain a deliberately restricted view of the larynx to facilitate passage of the endotracheal tube. We used the GlideScopeA (R) GVL video laryngoscope (GVL) to test whether deliberately obtaining a restricted view would result in faster and easier tracheal intubation than with a full view of the larynx. We recruited 163 elective surgical patients and randomly allocated the participants to one of two groups: Group F, where a full view of the larynx was obtained and held during GVL-facilitated tracheal intubation, and Group R, with a restricted view of the larynx (< 50% of glottic opening visible). Study investigators experienced in indirect VL performed the intubations. The intubations were recorded and the video recordings were subsequently assessed for total time to intubation, ease of intubation using a visual analogue scale (VAS; where 0 = easy and 100 = difficult), first-attempt success rate, and oxygen saturation after intubation. Complications were also assessed. The median [interquartile range (IQR)] time to intubation was faster in Group R than in Group F (27 [22-36] sec vs 36 [27-48] sec, respectively; median difference, 9 sec; 95% confidence interval [CI], 5 to 13; P < 0.001). The median [IQR] VAS rating for ease of intubation was also better in Group R than in Group F (14 [6-42) mm vs 50 mm [17-65], respectively; median difference, 20 mm; 95% CI, 10 to 31; P < 0.001). There was no difference between groups regarding the first-attempt success rate, oxygen saturation immediately after intubation, or complications. Using the GVL with a deliberately restricted view of the larynx resulted in faster and easier tracheal intubation than with a full view and with no additional complications. Our study suggests that obtaining a full or Cormack-Lehane grade 1 view may not be desirable when using the GVL. This trial was registered at ClinicalTrials.gov: NCT02144207.
引用
收藏
页码:928 / 937
页数:10
相关论文
共 25 条
[1]   Practice Guidelines for Management of the Difficult Airway An Updated Report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway [J].
Apfelbaum J.L. ;
Hagberg C.A. ;
Caplan R.A. ;
Connis R.T. ;
Nickinovich D.G. ;
Benumof J.L. ;
Berry F.A. ;
Blitt C.D. ;
Bode R.H. ;
Cheney F.W. ;
Guidry O.F. ;
Ovassapian A. .
ANESTHESIOLOGY, 2013, 118 (02) :251-270
[2]  
Anderson Jennifer, 2014, Anesthesiol Clin, V32, P445, DOI 10.1016/j.anclin.2014.02.022
[3]   First-Attempt Intubation Success of Video Laryngoscopy in Patients with Anticipated Difficult Direct Laryngoscopy: A Multicenter Randomized Controlled Trial Comparing the C-MAC D-Blade Versus the GlideScope in a Mixed Provider and Diverse Patient Population [J].
Aziz, Michael F. ;
Abrons, Ron O. ;
Cattano, Davide ;
Bayman, Emine O. ;
Swanson, David E. ;
Hagberg, Carin A. ;
Todd, Michael M. ;
Brambrink, Ansgar M. .
ANESTHESIA AND ANALGESIA, 2016, 122 (03) :740-750
[4]   Routine Clinical Practice Effectiveness of the Glidescope in Difficult Airway Management An Analysis of 2,004 Glidescope Intubations, Complications, and Failures from Two Institutions [J].
Aziz, Michael F. ;
Healy, David ;
Kheterpal, Sachin ;
Fu, Rongwei F. ;
Dillman, Dawn ;
Brambrink, Ansgar M. .
ANESTHESIOLOGY, 2011, 114 (01) :34-41
[5]  
Cooper R, 2011, MANAGEMENT DIFFICULT
[6]  
Cooper RM, 2005, CAN J ANAESTH, V52, P191, DOI 10.1007/BF03027728
[7]   DIFFICULT TRACHEAL INTUBATION IN OBSTETRICS [J].
CORMACK, RS ;
LEHANE, J .
ANAESTHESIA, 1984, 39 (11) :1105-1111
[8]   Defining and developing expertise in tracheal intubation using a GlideScope® for anaesthetists with expertise in Macintosh direct laryngoscopy: an in-vivo longitudinal study [J].
Cortellazzi, P. ;
Caldiroli, D. ;
Byrne, A. ;
Sommariva, A. ;
Orena, E. F. ;
Tramacere, I. .
ANAESTHESIA, 2015, 70 (03) :290-295
[9]   A signed-rank test for clustered data [J].
Datta, Somnath ;
Satten, Glen A. .
BIOMETRICS, 2008, 64 (02) :501-507
[10]   Optimizing GlideScope® laryngoscopy:: An in vitro study on an airway model [J].
Dupanovic, Mirsad ;
Jensen, Richard .
ANESTHESIOLOGY, 2007, 106 (04) :886-888